阿米替林和去甲替林血浆水平评估的质量控制:一项多中心研究。

P Baumann, U Breyer-Pfaff, H J Kuss, B Müller-Oerlinghausen, M Sandoz
{"title":"阿米替林和去甲替林血浆水平评估的质量控制:一项多中心研究。","authors":"P Baumann,&nbsp;U Breyer-Pfaff,&nbsp;H J Kuss,&nbsp;B Müller-Oerlinghausen,&nbsp;M Sandoz","doi":"10.1055/s-2007-1019529","DOIUrl":null,"url":null,"abstract":"<p><p>Numerous studies report about the relationship between the clinical effectiveness of amitriptyline (At) and the plasma level of this drug and of its most important metabolite, nortriptyline (Nt). These agents are therefore very frequently examined for clinical applications and for research programmes in specialized laboratories. The experience with antiepileptic drugs suggests the necessity of quality controls for antidepressants also. Therefore, five institutions in Western Europe performed two such experiments within a year. Two kinds of blood samples were sent for analysis: 1. plasma samples spiked with different quantities of At and Nt from an untreated subject; 2. plasma samples from patients treated with clinical doses of At. Each laboratory happened to use a different analytical method: TLC, HPLC, GC-NPD, GC-FID and GC-MS. The results clearly show the usefulness and the necessity of quality controls for this category of drugs as well. They form the basis for the improvement of the methods of each laboratory in particular. In this context, intralaboratory quality controls are also possible, if one disposes of two different methods. The findings of this study suggest that published reports on relationships between clinical and pharmacological parameters should be considered critically as to possible methodological bias.</p>","PeriodicalId":19840,"journal":{"name":"Pharmacopsychiatria","volume":"15 5","pages":"156-60"},"PeriodicalIF":0.0000,"publicationDate":"1982-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-2007-1019529","citationCount":"3","resultStr":"{\"title\":\"Quality control of amitriptyline and nortriptyline plasma level assessments: a multicenter study.\",\"authors\":\"P Baumann,&nbsp;U Breyer-Pfaff,&nbsp;H J Kuss,&nbsp;B Müller-Oerlinghausen,&nbsp;M Sandoz\",\"doi\":\"10.1055/s-2007-1019529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Numerous studies report about the relationship between the clinical effectiveness of amitriptyline (At) and the plasma level of this drug and of its most important metabolite, nortriptyline (Nt). These agents are therefore very frequently examined for clinical applications and for research programmes in specialized laboratories. The experience with antiepileptic drugs suggests the necessity of quality controls for antidepressants also. Therefore, five institutions in Western Europe performed two such experiments within a year. Two kinds of blood samples were sent for analysis: 1. plasma samples spiked with different quantities of At and Nt from an untreated subject; 2. plasma samples from patients treated with clinical doses of At. Each laboratory happened to use a different analytical method: TLC, HPLC, GC-NPD, GC-FID and GC-MS. The results clearly show the usefulness and the necessity of quality controls for this category of drugs as well. They form the basis for the improvement of the methods of each laboratory in particular. In this context, intralaboratory quality controls are also possible, if one disposes of two different methods. The findings of this study suggest that published reports on relationships between clinical and pharmacological parameters should be considered critically as to possible methodological bias.</p>\",\"PeriodicalId\":19840,\"journal\":{\"name\":\"Pharmacopsychiatria\",\"volume\":\"15 5\",\"pages\":\"156-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/s-2007-1019529\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmacopsychiatria\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-2007-1019529\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmacopsychiatria","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-2007-1019529","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

大量研究报道了阿米替林(At)的临床疗效与阿米替林及其最重要的代谢物去甲替林(Nt)的血浆水平之间的关系。因此,这些药物经常在临床应用和专门实验室的研究项目中进行检查。抗癫痫药的经验表明,抗抑郁药的质量控制也是必要的。因此,西欧的五家机构在一年内进行了两次这样的实验。两种血样被送去分析:1。未经治疗的受试者血浆样品中加入了不同数量的At和Nt;2. 接受临床剂量At治疗的患者的血浆样本。每个实验室碰巧使用不同的分析方法:TLC, HPLC, GC-NPD, GC-FID和GC-MS。结果清楚地表明了对该类药品进行质量控制的有效性和必要性。它们尤其构成了改进每个实验室方法的基础。在这种情况下,如果处理两种不同的方法,也可以进行实验室内质量控制。这项研究的结果表明,发表的关于临床和药理学参数之间关系的报告应该严格考虑可能的方法学偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quality control of amitriptyline and nortriptyline plasma level assessments: a multicenter study.

Numerous studies report about the relationship between the clinical effectiveness of amitriptyline (At) and the plasma level of this drug and of its most important metabolite, nortriptyline (Nt). These agents are therefore very frequently examined for clinical applications and for research programmes in specialized laboratories. The experience with antiepileptic drugs suggests the necessity of quality controls for antidepressants also. Therefore, five institutions in Western Europe performed two such experiments within a year. Two kinds of blood samples were sent for analysis: 1. plasma samples spiked with different quantities of At and Nt from an untreated subject; 2. plasma samples from patients treated with clinical doses of At. Each laboratory happened to use a different analytical method: TLC, HPLC, GC-NPD, GC-FID and GC-MS. The results clearly show the usefulness and the necessity of quality controls for this category of drugs as well. They form the basis for the improvement of the methods of each laboratory in particular. In this context, intralaboratory quality controls are also possible, if one disposes of two different methods. The findings of this study suggest that published reports on relationships between clinical and pharmacological parameters should be considered critically as to possible methodological bias.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信