{"title":"粒径分布分析作为检测显著细菌的快速方法。","authors":"J S Baker, G M Ederer, D Mundschenk","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Particle size distribution analysis (PSDA) was evaluated as a rapid screening method for detecting significant bacteriuria by linking a C1000 Channelyzer to a Coulter Counter. Colony counts and PSDA screening results were compared for 800 urine specimens. The PSDA method proved to be 92% specific, but only 64% sensitive, for detecting at least 10(5) colony forming units (CFU)/ml. By performing serial dilution colony counts on 109 culture-positive specimens (greater than or equal to 10(5) CFU/ml), it was determined that the low level of sensitivity (64%) was due to culture-positive specimens that had between 10(5) and less than 10(7) CFU/ml. The sensitivity of the PSDA method increased to 90% and 100% when culture-positive specimens had 10(7) or more and 10(8) or more CFU/ml, respectively. The low level of sensitivity demonstrated in this investigation makes the introduction of this method into clinical usage unacceptable at this time.</p>","PeriodicalId":76595,"journal":{"name":"The American journal of medical technology","volume":"49 10","pages":"727-32"},"PeriodicalIF":0.0000,"publicationDate":"1983-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Particle size distribution analysis as a rapid method to detect significant bacteriuria.\",\"authors\":\"J S Baker, G M Ederer, D Mundschenk\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Particle size distribution analysis (PSDA) was evaluated as a rapid screening method for detecting significant bacteriuria by linking a C1000 Channelyzer to a Coulter Counter. Colony counts and PSDA screening results were compared for 800 urine specimens. The PSDA method proved to be 92% specific, but only 64% sensitive, for detecting at least 10(5) colony forming units (CFU)/ml. By performing serial dilution colony counts on 109 culture-positive specimens (greater than or equal to 10(5) CFU/ml), it was determined that the low level of sensitivity (64%) was due to culture-positive specimens that had between 10(5) and less than 10(7) CFU/ml. The sensitivity of the PSDA method increased to 90% and 100% when culture-positive specimens had 10(7) or more and 10(8) or more CFU/ml, respectively. The low level of sensitivity demonstrated in this investigation makes the introduction of this method into clinical usage unacceptable at this time.</p>\",\"PeriodicalId\":76595,\"journal\":{\"name\":\"The American journal of medical technology\",\"volume\":\"49 10\",\"pages\":\"727-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The American journal of medical technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The American journal of medical technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Particle size distribution analysis as a rapid method to detect significant bacteriuria.
Particle size distribution analysis (PSDA) was evaluated as a rapid screening method for detecting significant bacteriuria by linking a C1000 Channelyzer to a Coulter Counter. Colony counts and PSDA screening results were compared for 800 urine specimens. The PSDA method proved to be 92% specific, but only 64% sensitive, for detecting at least 10(5) colony forming units (CFU)/ml. By performing serial dilution colony counts on 109 culture-positive specimens (greater than or equal to 10(5) CFU/ml), it was determined that the low level of sensitivity (64%) was due to culture-positive specimens that had between 10(5) and less than 10(7) CFU/ml. The sensitivity of the PSDA method increased to 90% and 100% when culture-positive specimens had 10(7) or more and 10(8) or more CFU/ml, respectively. The low level of sensitivity demonstrated in this investigation makes the introduction of this method into clinical usage unacceptable at this time.