金属过敏,金属植入物和骨折愈合。

S A Brown, S D Devine, K Merritt
{"title":"金属过敏,金属植入物和骨折愈合。","authors":"S A Brown,&nbsp;S D Devine,&nbsp;K Merritt","doi":"10.3109/10731198309118796","DOIUrl":null,"url":null,"abstract":"<p><p>The rabbit tibia was used as a model to study the effects of metal sensitivity reactions on the healing of fractures. Animals were injected with nickel chloride in Freund's complete adjuvant to cause sensitivity, and fractures were stabilized with 316L stainless steel intramedullary rods and followed for 16 weeks. A control group received no injections. The response was evaluated biomechanically with torsional testing at sacrifice, radiologically by examining the roentgenograms for evidence of loosening, and histologically. The results demonstrated a slight decrease in strength, a moderate increase in resorption and a significant decrease in cellularity and new bone formation in the sensitive animals as compared to control. These results are consistent with a reaction of comparatively short duration.</p>","PeriodicalId":75597,"journal":{"name":"Biomaterials, medical devices, and artificial organs","volume":"11 1","pages":"73-81"},"PeriodicalIF":0.0000,"publicationDate":"1983-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731198309118796","citationCount":"7","resultStr":"{\"title\":\"Metal allergy, metal implants and fracture healing.\",\"authors\":\"S A Brown,&nbsp;S D Devine,&nbsp;K Merritt\",\"doi\":\"10.3109/10731198309118796\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The rabbit tibia was used as a model to study the effects of metal sensitivity reactions on the healing of fractures. Animals were injected with nickel chloride in Freund's complete adjuvant to cause sensitivity, and fractures were stabilized with 316L stainless steel intramedullary rods and followed for 16 weeks. A control group received no injections. The response was evaluated biomechanically with torsional testing at sacrifice, radiologically by examining the roentgenograms for evidence of loosening, and histologically. The results demonstrated a slight decrease in strength, a moderate increase in resorption and a significant decrease in cellularity and new bone formation in the sensitive animals as compared to control. These results are consistent with a reaction of comparatively short duration.</p>\",\"PeriodicalId\":75597,\"journal\":{\"name\":\"Biomaterials, medical devices, and artificial organs\",\"volume\":\"11 1\",\"pages\":\"73-81\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731198309118796\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterials, medical devices, and artificial organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731198309118796\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, medical devices, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731198309118796","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

以家兔胫骨为模型,研究金属敏感性反应对骨折愈合的影响。动物注射氯化镍作为Freund's完全佐剂引起敏感性,骨折用316L不锈钢髓内棒稳定,随访16周。对照组不接受注射。通过牺牲时的扭转测试来评估生物力学反应,通过x线片检查松动的证据来评估放射学反应,以及组织学反应。结果显示,与对照组相比,敏感动物的强度略有下降,吸收适度增加,细胞数量和新骨形成显著减少。这些结果与持续时间相对较短的反应相一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Metal allergy, metal implants and fracture healing.

The rabbit tibia was used as a model to study the effects of metal sensitivity reactions on the healing of fractures. Animals were injected with nickel chloride in Freund's complete adjuvant to cause sensitivity, and fractures were stabilized with 316L stainless steel intramedullary rods and followed for 16 weeks. A control group received no injections. The response was evaluated biomechanically with torsional testing at sacrifice, radiologically by examining the roentgenograms for evidence of loosening, and histologically. The results demonstrated a slight decrease in strength, a moderate increase in resorption and a significant decrease in cellularity and new bone formation in the sensitive animals as compared to control. These results are consistent with a reaction of comparatively short duration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信