{"title":"A型肝炎病毒igm抗体的“反向”固相放射免疫测定。","authors":"O H Meurman, L Matter, R V Krishna, U H Krech","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A \"reverse\"solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and 125I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sea was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar \"reverse\" immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens.</p>","PeriodicalId":75411,"journal":{"name":"Acta pathologica et microbiologica Scandinavica. Section C, Immunology","volume":"89 2","pages":"79-84"},"PeriodicalIF":0.0000,"publicationDate":"1981-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A \\\"reverse\\\" solid-phase radio-immuno-assay for IgM-antibodies to hepatitis A virus.\",\"authors\":\"O H Meurman, L Matter, R V Krishna, U H Krech\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A \\\"reverse\\\"solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and 125I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sea was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar \\\"reverse\\\" immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens.</p>\",\"PeriodicalId\":75411,\"journal\":{\"name\":\"Acta pathologica et microbiologica Scandinavica. Section C, Immunology\",\"volume\":\"89 2\",\"pages\":\"79-84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta pathologica et microbiologica Scandinavica. Section C, Immunology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta pathologica et microbiologica Scandinavica. Section C, Immunology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A "reverse" solid-phase radio-immuno-assay for IgM-antibodies to hepatitis A virus.
A "reverse"solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and 125I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sea was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar "reverse" immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens.