[呼吸和呼吸暂停时电阻抗容积描记术测量心输出量]。

R L Tanguy, J F Morin, D Deredec, Y Guedes, C Riche, J P Egreteau
{"title":"[呼吸和呼吸暂停时电阻抗容积描记术测量心输出量]。","authors":"R L Tanguy,&nbsp;J F Morin,&nbsp;D Deredec,&nbsp;Y Guedes,&nbsp;C Riche,&nbsp;J P Egreteau","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The measurement of cardiac output by electrical impedance plethysmography (non-invasive technique) may be disturbed by a certain number of factors, including respiration. The authors sought to demonstrate that this factor could be eliminated during measurement calculations. By this method, in 18 adult subjects with coronary artery disease, 50 measurements during respiration and 50 measurements in apnoea (paired measurements) of stroke volume and of cardiac output were performed. Stroke volume was calculated using Kubicek's formula: SV = P(L2/Zo2) (dz/dt min)t Results were as follows: highly significant correlation between values for stroke volume obtained during respiration and in apnoea (r ;.9767; n=50; P < 0.001); highly significant correlation between values for cardiac output obtained under the same conditions (r = 0.9744; n=50; P < 0.001). The authors conclude that with the limits of certain technical conditions of measurement, respiration does not disturb measurements of stroke volume and of cardiac output by electrical impedance plethysmography.</p>","PeriodicalId":8081,"journal":{"name":"Annales de l'anesthesiologie francaise","volume":"21 5","pages":"567-71"},"PeriodicalIF":0.0000,"publicationDate":"1980-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Measurement of cardiac output by electrical impedance plethysmography during respiration and in apnea].\",\"authors\":\"R L Tanguy,&nbsp;J F Morin,&nbsp;D Deredec,&nbsp;Y Guedes,&nbsp;C Riche,&nbsp;J P Egreteau\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The measurement of cardiac output by electrical impedance plethysmography (non-invasive technique) may be disturbed by a certain number of factors, including respiration. The authors sought to demonstrate that this factor could be eliminated during measurement calculations. By this method, in 18 adult subjects with coronary artery disease, 50 measurements during respiration and 50 measurements in apnoea (paired measurements) of stroke volume and of cardiac output were performed. Stroke volume was calculated using Kubicek's formula: SV = P(L2/Zo2) (dz/dt min)t Results were as follows: highly significant correlation between values for stroke volume obtained during respiration and in apnoea (r ;.9767; n=50; P < 0.001); highly significant correlation between values for cardiac output obtained under the same conditions (r = 0.9744; n=50; P < 0.001). The authors conclude that with the limits of certain technical conditions of measurement, respiration does not disturb measurements of stroke volume and of cardiac output by electrical impedance plethysmography.</p>\",\"PeriodicalId\":8081,\"journal\":{\"name\":\"Annales de l'anesthesiologie francaise\",\"volume\":\"21 5\",\"pages\":\"567-71\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales de l'anesthesiologie francaise\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de l'anesthesiologie francaise","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电阻抗容积描记术(无创技术)测量心输出量时,可能会受到若干因素的干扰,包括呼吸。作者试图证明这个因素可以在测量计算中消除。采用该方法,对18例冠心病成人受试者进行了50次呼吸时和50次呼吸暂停时的脑卒中量和心输出量(成对测量)。脑卒中量计算采用Kubicek公式:SV = P(L2/Zo2) (dz/dt min)t结果如下:呼吸时脑卒中量与呼吸暂停时脑卒中量呈极显著相关(r;.9767;n = 50;P < 0.001);在相同条件下获得的心输出量值之间具有高度显著的相关性(r = 0.9744;n = 50;P < 0.001)。作者得出结论,在一定的测量技术条件的限制下,呼吸不会干扰电阻抗容积描记术测量的脑搏量和心输出量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Measurement of cardiac output by electrical impedance plethysmography during respiration and in apnea].

The measurement of cardiac output by electrical impedance plethysmography (non-invasive technique) may be disturbed by a certain number of factors, including respiration. The authors sought to demonstrate that this factor could be eliminated during measurement calculations. By this method, in 18 adult subjects with coronary artery disease, 50 measurements during respiration and 50 measurements in apnoea (paired measurements) of stroke volume and of cardiac output were performed. Stroke volume was calculated using Kubicek's formula: SV = P(L2/Zo2) (dz/dt min)t Results were as follows: highly significant correlation between values for stroke volume obtained during respiration and in apnoea (r ;.9767; n=50; P < 0.001); highly significant correlation between values for cardiac output obtained under the same conditions (r = 0.9744; n=50; P < 0.001). The authors conclude that with the limits of certain technical conditions of measurement, respiration does not disturb measurements of stroke volume and of cardiac output by electrical impedance plethysmography.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信