{"title":"人类骨骼与钛植入物反应的扫描电镜研究","authors":"G. Krekeler , H.F. Kappert, W. Schilli","doi":"10.1016/S0300-9785(85)80078-8","DOIUrl":null,"url":null,"abstract":"<div><p>An endosteal implant which had been functional had to be removed from the mandible after 13 months; this implant was made available for investigation in the scanning electron microscope. It was seen that an ankylotic bond between bone and implant had been achieved under natural loading conditions.</p></div>","PeriodicalId":14224,"journal":{"name":"International journal of oral surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1985-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0300-9785(85)80078-8","citationCount":"8","resultStr":"{\"title\":\"Scanning electron microscopic study of the reaction of human bone to a titanium implant\",\"authors\":\"G. Krekeler , H.F. Kappert, W. Schilli\",\"doi\":\"10.1016/S0300-9785(85)80078-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An endosteal implant which had been functional had to be removed from the mandible after 13 months; this implant was made available for investigation in the scanning electron microscope. It was seen that an ankylotic bond between bone and implant had been achieved under natural loading conditions.</p></div>\",\"PeriodicalId\":14224,\"journal\":{\"name\":\"International journal of oral surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0300-9785(85)80078-8\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0300978585800788\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300978585800788","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Scanning electron microscopic study of the reaction of human bone to a titanium implant
An endosteal implant which had been functional had to be removed from the mandible after 13 months; this implant was made available for investigation in the scanning electron microscope. It was seen that an ankylotic bond between bone and implant had been achieved under natural loading conditions.