颞下颌关节镜检查

Anders Holmlund , Gustaf Hellsing
{"title":"颞下颌关节镜检查","authors":"Anders Holmlund ,&nbsp;Gustaf Hellsing","doi":"10.1016/S0300-9785(85)80089-2","DOIUrl":null,"url":null,"abstract":"<div><p>Arthroscopy of the temporomandibular joint (TMJ) is evaluated on an autopsy material, 2 different types of arthroscope — one with a rod-lens system and one with a so-called Selfoc system — were used and compared regarding diagnostic accuracy. On 54 cadavers, it was found that the upper joint compartment may be punctured with accuracy and without damage to vital tissues. Landmarks on the skin facilitating clinical arthroscopy were defined in relation to a guideline from tragus to lateral canthus. A further 49 TMJ specimens were investigated with arthroscopy. The findings are in good agreement with subsequent observations made during dissection. Regarding arthrotic changes, 100% diagnostic accuracy was achieved with both types of arthroscope. Regarding remodelling changes, the diagnostic accuracy was approximately 57%. No significant difference was noticed between the 2 arthroscopes. Photographic documentation with the rod-lens arthroscope was found to be of superior quality.</p></div>","PeriodicalId":14224,"journal":{"name":"International journal of oral surgery","volume":"14 2","pages":"Pages 169-175"},"PeriodicalIF":0.0000,"publicationDate":"1985-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0300-9785(85)80089-2","citationCount":"111","resultStr":"{\"title\":\"Arthroscopy of the temporomandibular joint\",\"authors\":\"Anders Holmlund ,&nbsp;Gustaf Hellsing\",\"doi\":\"10.1016/S0300-9785(85)80089-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Arthroscopy of the temporomandibular joint (TMJ) is evaluated on an autopsy material, 2 different types of arthroscope — one with a rod-lens system and one with a so-called Selfoc system — were used and compared regarding diagnostic accuracy. On 54 cadavers, it was found that the upper joint compartment may be punctured with accuracy and without damage to vital tissues. Landmarks on the skin facilitating clinical arthroscopy were defined in relation to a guideline from tragus to lateral canthus. A further 49 TMJ specimens were investigated with arthroscopy. The findings are in good agreement with subsequent observations made during dissection. Regarding arthrotic changes, 100% diagnostic accuracy was achieved with both types of arthroscope. Regarding remodelling changes, the diagnostic accuracy was approximately 57%. No significant difference was noticed between the 2 arthroscopes. Photographic documentation with the rod-lens arthroscope was found to be of superior quality.</p></div>\",\"PeriodicalId\":14224,\"journal\":{\"name\":\"International journal of oral surgery\",\"volume\":\"14 2\",\"pages\":\"Pages 169-175\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0300-9785(85)80089-2\",\"citationCount\":\"111\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0300978585800892\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300978585800892","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 111

摘要

在尸检材料上评估了颞下颌关节(TMJ)的关节镜,使用了两种不同类型的关节镜,一种是杆状透镜系统,一种是所谓的Selfoc系统,并对其诊断准确性进行了比较。在54具尸体上,发现可以准确地刺穿上部关节室,而不会损伤重要组织。根据从耳屏到外眦的指引,确定了便于临床关节镜检查的皮肤标志。另外49例TMJ标本经关节镜检查。这些发现与解剖过程中所做的观察结果很好地吻合。对于关节改变,两种类型的关节镜的诊断准确率均达到100%。关于重塑改变,诊断准确率约为57%。两种关节镜检查结果无明显差异。杆状透镜关节镜下的摄影文献质量较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Arthroscopy of the temporomandibular joint

Arthroscopy of the temporomandibular joint (TMJ) is evaluated on an autopsy material, 2 different types of arthroscope — one with a rod-lens system and one with a so-called Selfoc system — were used and compared regarding diagnostic accuracy. On 54 cadavers, it was found that the upper joint compartment may be punctured with accuracy and without damage to vital tissues. Landmarks on the skin facilitating clinical arthroscopy were defined in relation to a guideline from tragus to lateral canthus. A further 49 TMJ specimens were investigated with arthroscopy. The findings are in good agreement with subsequent observations made during dissection. Regarding arthrotic changes, 100% diagnostic accuracy was achieved with both types of arthroscope. Regarding remodelling changes, the diagnostic accuracy was approximately 57%. No significant difference was noticed between the 2 arthroscopes. Photographic documentation with the rod-lens arthroscope was found to be of superior quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信