Jeeyeon Lee, Bora Yang, Won Hwa Kim, Jaeil Kim, Ho Yong Park, Byeongju Kang, Joon Suk Moon, Hai Lin Park
{"title":"确定实时人工智能辅助超声在乳腺低怀疑恶性病变中的临床适应症。","authors":"Jeeyeon Lee, Bora Yang, Won Hwa Kim, Jaeil Kim, Ho Yong Park, Byeongju Kang, Joon Suk Moon, Hai Lin Park","doi":"10.1002/jum.70439","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate whether real-time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI-RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided.</p><p><strong>Methods: </strong>This retrospective analysis of single-center biopsy registry included 641 consecutive US BI-RADS 4A lesions that underwent vacuum-assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real-time AI US system (CadAI-B®), and MMG findings were classified as suspicious or non-suspicious based on formal reports. Seven prespecified biopsy-decision strategies were evaluated, including 3 AI-only strategies, 3 mammography-gated AI strategies, and the current standard strategy of biopsy all BI-RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard.</p><p><strong>Results: </strong>Among 641 cases of US BI-RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI-RADS categories 1-3. AI-only biopsy-deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI-RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI-RADS 1-3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI-RADS ≤3 and non-suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1-100.0%) and increasing specificity to 45.4% (95% CI, 41.4-49.4%).</p><p><strong>Conclusion: </strong>Real-time AI breast US alone could not safely support biopsy deferral in US BI-RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low-risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real-time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.</p>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Defining the Clinical Indication for Real-Time Artificial Intelligence-Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy.\",\"authors\":\"Jeeyeon Lee, Bora Yang, Won Hwa Kim, Jaeil Kim, Ho Yong Park, Byeongju Kang, Joon Suk Moon, Hai Lin Park\",\"doi\":\"10.1002/jum.70439\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate whether real-time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI-RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided.</p><p><strong>Methods: </strong>This retrospective analysis of single-center biopsy registry included 641 consecutive US BI-RADS 4A lesions that underwent vacuum-assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real-time AI US system (CadAI-B®), and MMG findings were classified as suspicious or non-suspicious based on formal reports. Seven prespecified biopsy-decision strategies were evaluated, including 3 AI-only strategies, 3 mammography-gated AI strategies, and the current standard strategy of biopsy all BI-RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard.</p><p><strong>Results: </strong>Among 641 cases of US BI-RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI-RADS categories 1-3. AI-only biopsy-deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI-RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI-RADS 1-3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI-RADS ≤3 and non-suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1-100.0%) and increasing specificity to 45.4% (95% CI, 41.4-49.4%).</p><p><strong>Conclusion: </strong>Real-time AI breast US alone could not safely support biopsy deferral in US BI-RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low-risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real-time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.</p>\",\"PeriodicalId\":17563,\"journal\":{\"name\":\"Journal of Ultrasound in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2026-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jum.70439\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jum.70439","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
Defining the Clinical Indication for Real-Time Artificial Intelligence-Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy.
Objectives: To evaluate whether real-time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI-RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided.
Methods: This retrospective analysis of single-center biopsy registry included 641 consecutive US BI-RADS 4A lesions that underwent vacuum-assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real-time AI US system (CadAI-B®), and MMG findings were classified as suspicious or non-suspicious based on formal reports. Seven prespecified biopsy-decision strategies were evaluated, including 3 AI-only strategies, 3 mammography-gated AI strategies, and the current standard strategy of biopsy all BI-RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard.
Results: Among 641 cases of US BI-RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI-RADS categories 1-3. AI-only biopsy-deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI-RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI-RADS 1-3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI-RADS ≤3 and non-suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1-100.0%) and increasing specificity to 45.4% (95% CI, 41.4-49.4%).
Conclusion: Real-time AI breast US alone could not safely support biopsy deferral in US BI-RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low-risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real-time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.
期刊介绍:
The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community.
Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to:
-Basic Science-
Breast Ultrasound-
Contrast-Enhanced Ultrasound-
Dermatology-
Echocardiography-
Elastography-
Emergency Medicine-
Fetal Echocardiography-
Gastrointestinal Ultrasound-
General and Abdominal Ultrasound-
Genitourinary Ultrasound-
Gynecologic Ultrasound-
Head and Neck Ultrasound-
High Frequency Clinical and Preclinical Imaging-
Interventional-Intraoperative Ultrasound-
Musculoskeletal Ultrasound-
Neurosonology-
Obstetric Ultrasound-
Ophthalmologic Ultrasound-
Pediatric Ultrasound-
Point-of-Care Ultrasound-
Public Policy-
Superficial Structures-
Therapeutic Ultrasound-
Ultrasound Education-
Ultrasound in Global Health-
Urologic Ultrasound-
Vascular Ultrasound