{"title":"术中输液治疗。输液加热器给药率评价及疗效评价[j]。","authors":"J Nagler","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A look at the efficiency of infusion warmers from the clinician's point of view must be based on the infusion rates usually necessary in the operating room. Therefore a retrospective evaluation of 1,510 anesthesia records was made in order to register the flow rate of every infusion. As a general rule the flow rate did not exceed 1.5 1/h. Our past warming apparatus was found not very effective in this range under the standard conditions of a cold operating room with laminar air flow. A new in-line warmer, fast and easy to handle, proved superior in daily use.</p>","PeriodicalId":75931,"journal":{"name":"Infusionstherapie und klinische Ernahrung","volume":"13 5","pages":"216-9"},"PeriodicalIF":0.0000,"publicationDate":"1986-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Intraoperative infusion therapy. Evaluation of the rate of administration and assessment of the effectiveness of infusion warmers].\",\"authors\":\"J Nagler\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A look at the efficiency of infusion warmers from the clinician's point of view must be based on the infusion rates usually necessary in the operating room. Therefore a retrospective evaluation of 1,510 anesthesia records was made in order to register the flow rate of every infusion. As a general rule the flow rate did not exceed 1.5 1/h. Our past warming apparatus was found not very effective in this range under the standard conditions of a cold operating room with laminar air flow. A new in-line warmer, fast and easy to handle, proved superior in daily use.</p>\",\"PeriodicalId\":75931,\"journal\":{\"name\":\"Infusionstherapie und klinische Ernahrung\",\"volume\":\"13 5\",\"pages\":\"216-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infusionstherapie und klinische Ernahrung\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infusionstherapie und klinische Ernahrung","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Intraoperative infusion therapy. Evaluation of the rate of administration and assessment of the effectiveness of infusion warmers].
A look at the efficiency of infusion warmers from the clinician's point of view must be based on the infusion rates usually necessary in the operating room. Therefore a retrospective evaluation of 1,510 anesthesia records was made in order to register the flow rate of every infusion. As a general rule the flow rate did not exceed 1.5 1/h. Our past warming apparatus was found not very effective in this range under the standard conditions of a cold operating room with laminar air flow. A new in-line warmer, fast and easy to handle, proved superior in daily use.