Kathleen A. Farley, David Foley, Robert Krull, Martin Hoffman, Anna Codina, Peter Dorff, Christopher W. am Ende, Ormacinda White, Stephen W. Wright
{"title":"新一代核磁共振流管优化小体积核磁共振反应监测在临床前药物发现","authors":"Kathleen A. Farley, David Foley, Robert Krull, Martin Hoffman, Anna Codina, Peter Dorff, Christopher W. am Ende, Ormacinda White, Stephen W. Wright","doi":"10.1021/acsmedchemlett.6c00388","DOIUrl":null,"url":null,"abstract":"<p>We developed a 3 mm NMR flow tube that can be inserted\r\ninto a 5\r\nmm NMR probe converting a high field NMR spectrometer into a reaction\r\nmonitoring system with a minimum reaction volume of 2 mL. The system\r\nuses a standard LC pump to flow the reaction mixture from a reaction\r\nvial in an integrated heating block to the center of the magnet for\r\ndetection before returning the mixture back to the vial. The NMR flow\r\ntube has a temperature range of −20 to 120 °C and the\r\nNMR instrument can be switched from NMR tubes to the flow tube mode\r\nin a few minutes. We report the use of this flow NMR small volume\r\nsystem to monitor the progress of two chemical reactions that resisted\r\nstudy by more common analytical techniques.</p>","PeriodicalId":20,"journal":{"name":"ACS Medicinal Chemistry Letters","volume":"17 10","pages":"2106–2113"},"PeriodicalIF":3.9000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Next Generation NMR Flow Tube Optimized for Small Volume NMR Reaction Monitoring in Preclinical Drug Discovery\",\"authors\":\"Kathleen A. Farley, David Foley, Robert Krull, Martin Hoffman, Anna Codina, Peter Dorff, Christopher W. am Ende, Ormacinda White, Stephen W. Wright\",\"doi\":\"10.1021/acsmedchemlett.6c00388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>We developed a 3 mm NMR flow tube that can be inserted\\r\\ninto a 5\\r\\nmm NMR probe converting a high field NMR spectrometer into a reaction\\r\\nmonitoring system with a minimum reaction volume of 2 mL. The system\\r\\nuses a standard LC pump to flow the reaction mixture from a reaction\\r\\nvial in an integrated heating block to the center of the magnet for\\r\\ndetection before returning the mixture back to the vial. The NMR flow\\r\\ntube has a temperature range of −20 to 120 °C and the\\r\\nNMR instrument can be switched from NMR tubes to the flow tube mode\\r\\nin a few minutes. We report the use of this flow NMR small volume\\r\\nsystem to monitor the progress of two chemical reactions that resisted\\r\\nstudy by more common analytical techniques.</p>\",\"PeriodicalId\":20,\"journal\":{\"name\":\"ACS Medicinal Chemistry Letters\",\"volume\":\"17 10\",\"pages\":\"2106–2113\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2026-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Medicinal Chemistry Letters\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acsmedchemlett.6c00388\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/9/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MEDICINAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Medicinal Chemistry Letters","FirstCategoryId":"3","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsmedchemlett.6c00388","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
Next Generation NMR Flow Tube Optimized for Small Volume NMR Reaction Monitoring in Preclinical Drug Discovery
We developed a 3 mm NMR flow tube that can be inserted
into a 5
mm NMR probe converting a high field NMR spectrometer into a reaction
monitoring system with a minimum reaction volume of 2 mL. The system
uses a standard LC pump to flow the reaction mixture from a reaction
vial in an integrated heating block to the center of the magnet for
detection before returning the mixture back to the vial. The NMR flow
tube has a temperature range of −20 to 120 °C and the
NMR instrument can be switched from NMR tubes to the flow tube mode
in a few minutes. We report the use of this flow NMR small volume
system to monitor the progress of two chemical reactions that resisted
study by more common analytical techniques.
期刊介绍:
ACS Medicinal Chemistry Letters is interested in receiving manuscripts that discuss various aspects of medicinal chemistry. The journal will publish studies that pertain to a broad range of subject matter, including compound design and optimization, biological evaluation, drug delivery, imaging agents, and pharmacology of both small and large bioactive molecules. Specific areas include but are not limited to:
Identification, synthesis, and optimization of lead biologically active molecules and drugs (small molecules and biologics)
Biological characterization of new molecular entities in the context of drug discovery
Computational, cheminformatics, and structural studies for the identification or SAR analysis of bioactive molecules, ligands and their targets, etc.
Novel and improved methodologies, including radiation biochemistry, with broad application to medicinal chemistry
Discovery technologies for biologically active molecules from both synthetic and natural (plant and other) sources
Pharmacokinetic/pharmacodynamic studies that address mechanisms underlying drug disposition and response
Pharmacogenetic and pharmacogenomic studies used to enhance drug design and the translation of medicinal chemistry into the clinic
Mechanistic drug metabolism and regulation of metabolic enzyme gene expression
Chemistry patents relevant to the medicinal chemistry field.