{"title":"水诱导的超低滞后拓扑电离层凝胶用于动态足底压力传感和智能步态监测","authors":"Hongnan Zhu, Yicong Wang, Liang Zheng, Zhouyang Hu, Qiongyi Zhang, Jiangrui Gao, Senyun Yang, Jun Yang, Sanwei Hao, Jialong Wen, Feng Xu, Jing Rao, Caofeng Pan","doi":"10.1002/adfm.78918","DOIUrl":null,"url":null,"abstract":"Flexible plantar pressure sensors require soft ionic materials that can withstand large deformation, suppress hysteresis, and maintain reliable signal transduction under dynamic loading, yet these properties are rarely integrated in one material platform. Here, we report a water‐induced topological ionogel (WTI) enabled by competitive hydrogen‐bond regulation in an acrylic acid/acrylamide/[BMIM]Cl/H <jats:sub>2</jats:sub> O system. Water weakens rigid polymer‐ionic liquid associations and drives the transition from aggregated polymer clusters to a dynamically adaptive topological network, thereby promoting elastic recovery and reducing energy dissipation. The optimized WTI exhibits a compressive stress of 1.02 MPa at 90% strain, a hysteresis ratio of 8.3% at 50% strain, and an ionic conductivity of about 270 mS m <jats:sup>−1</jats:sup> . As a flexible pressure sensor, it delivers a response time of about 10 ms, a sensing range from 62.3 Pa to 200 kPa, and stable operation over 20,000 loading‐unloading cycles. Integrated into a wearable plantar pressure sensing system, it enables high‐resolution spatiotemporal pressure mapping and recognition of nine locomotor patterns with 99.18% accuracy through convolutional neural network analysis. This work provides a topology‐engineering strategy for low‐hysteresis ionogels for wearable biomechanical monitoring and intelligent healthcare.","PeriodicalId":112,"journal":{"name":"Advanced Functional Materials","volume":"6 1","pages":""},"PeriodicalIF":19.9000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Water‐Induced Topological Ionogels with Ultralow Hysteresis for Dynamic Plantar Pressure Sensing and Intelligent Gait Monitoring\",\"authors\":\"Hongnan Zhu, Yicong Wang, Liang Zheng, Zhouyang Hu, Qiongyi Zhang, Jiangrui Gao, Senyun Yang, Jun Yang, Sanwei Hao, Jialong Wen, Feng Xu, Jing Rao, Caofeng Pan\",\"doi\":\"10.1002/adfm.78918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flexible plantar pressure sensors require soft ionic materials that can withstand large deformation, suppress hysteresis, and maintain reliable signal transduction under dynamic loading, yet these properties are rarely integrated in one material platform. Here, we report a water‐induced topological ionogel (WTI) enabled by competitive hydrogen‐bond regulation in an acrylic acid/acrylamide/[BMIM]Cl/H <jats:sub>2</jats:sub> O system. Water weakens rigid polymer‐ionic liquid associations and drives the transition from aggregated polymer clusters to a dynamically adaptive topological network, thereby promoting elastic recovery and reducing energy dissipation. The optimized WTI exhibits a compressive stress of 1.02 MPa at 90% strain, a hysteresis ratio of 8.3% at 50% strain, and an ionic conductivity of about 270 mS m <jats:sup>−1</jats:sup> . As a flexible pressure sensor, it delivers a response time of about 10 ms, a sensing range from 62.3 Pa to 200 kPa, and stable operation over 20,000 loading‐unloading cycles. Integrated into a wearable plantar pressure sensing system, it enables high‐resolution spatiotemporal pressure mapping and recognition of nine locomotor patterns with 99.18% accuracy through convolutional neural network analysis. This work provides a topology‐engineering strategy for low‐hysteresis ionogels for wearable biomechanical monitoring and intelligent healthcare.\",\"PeriodicalId\":112,\"journal\":{\"name\":\"Advanced Functional Materials\",\"volume\":\"6 1\",\"pages\":\"\"},\"PeriodicalIF\":19.9000,\"publicationDate\":\"2026-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Functional Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1002/adfm.78918\",\"RegionNum\":1,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Functional Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1002/adfm.78918","RegionNum":1,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
柔性足底压力传感器需要柔软的离子材料,能够承受大变形,抑制迟滞,并在动载荷下保持可靠的信号转导,但这些特性很少集成在一个材料平台上。在这里,我们报道了在丙烯酸/丙烯酰胺/[BMIM]Cl/ h2o体系中通过竞争性氢键调节形成的水诱导拓扑电离凝胶(WTI)。水削弱刚性聚合物-离子液体的结合,驱动聚合聚合物团簇向动态自适应拓扑网络的转变,从而促进弹性恢复和减少能量耗散。优化后的WTI在90%应变下的压应力为1.02 MPa,在50%应变下的滞后率为8.3%,离子电导率约为270 mS m−1。作为一种柔性压力传感器,它的响应时间约为10 ms,感应范围为62.3 Pa至200 kPa,并且在20,000多个加载-卸载循环中稳定运行。集成到可穿戴足底压力传感系统中,通过卷积神经网络分析,可以实现高分辨率时空压力映射和识别九种运动模式,准确率达99.18%。这项工作为可穿戴生物力学监测和智能医疗的低滞后离子凝胶提供了一种拓扑工程策略。
Water‐Induced Topological Ionogels with Ultralow Hysteresis for Dynamic Plantar Pressure Sensing and Intelligent Gait Monitoring
Flexible plantar pressure sensors require soft ionic materials that can withstand large deformation, suppress hysteresis, and maintain reliable signal transduction under dynamic loading, yet these properties are rarely integrated in one material platform. Here, we report a water‐induced topological ionogel (WTI) enabled by competitive hydrogen‐bond regulation in an acrylic acid/acrylamide/[BMIM]Cl/H 2 O system. Water weakens rigid polymer‐ionic liquid associations and drives the transition from aggregated polymer clusters to a dynamically adaptive topological network, thereby promoting elastic recovery and reducing energy dissipation. The optimized WTI exhibits a compressive stress of 1.02 MPa at 90% strain, a hysteresis ratio of 8.3% at 50% strain, and an ionic conductivity of about 270 mS m −1 . As a flexible pressure sensor, it delivers a response time of about 10 ms, a sensing range from 62.3 Pa to 200 kPa, and stable operation over 20,000 loading‐unloading cycles. Integrated into a wearable plantar pressure sensing system, it enables high‐resolution spatiotemporal pressure mapping and recognition of nine locomotor patterns with 99.18% accuracy through convolutional neural network analysis. This work provides a topology‐engineering strategy for low‐hysteresis ionogels for wearable biomechanical monitoring and intelligent healthcare.
期刊介绍:
Firmly established as a top-tier materials science journal, Advanced Functional Materials reports breakthrough research in all aspects of materials science, including nanotechnology, chemistry, physics, and biology every week.
Advanced Functional Materials is known for its rapid and fair peer review, quality content, and high impact, making it the first choice of the international materials science community.