{"title":"一次性无标签电化学免疫传感器,使用表面约束二茂铁的空心多孔金亚微立方体用于m痘病毒A29蛋白的即时检测","authors":"Md Mahbubur Rahman Khan,&nbsp;Balamurugan Thangavel,&nbsp;Hyo-eun Kang,&nbsp;Joong Ho Shin","doi":"10.1016/j.talanta.2026.130633","DOIUrl":null,"url":null,"abstract":"<div><div>Monkeypox (Mpox), a viral zoonotic disease caused by the monkeypox virus (MPXV) remains a significant global public health concern. Current laboratory diagnostics are limited by high biosafety requirements and complex workflows, preventing point-of-care (POC) use. To address these limitations, a disposable, label-free electrochemical immunosensor was developed to detect the MPXV A29 glycoprotein, a highly immunogenic and diagnostically relevant protein. Shape-controlled, reproducible, hollow porous gold sub-microcubes (HPGCs) were synthesized using AgCl as a sacrificial template. The screen-printed carbon electrode was functionalized with poly-<span>l</span>-cysteine and HPGCs bearing a surface-confined 6-(ferrocenyl)hexanethiol probe and antibody for selective antigen binding. Antigen binding attenuates the ferrocene electrochemistry, investigated by voltammetry and impedance spectroscopy. The high surface-to-volume ratio and electrocatalytically active centers of HPGCs enable high loading of ferrocene and antibodies. The surface-confined signaling probe eliminates the need for an external signaling probe, offering a portable, reagent-free POC testing. The sensor offers a wide linear range (0.1–3200 ng/mL), low detection limit (0.1 ng/mL), excellent selectivity against non-target proteins, high reproducibility (RSD = 3.73%), and strong recovery in spiked serum with minimal matrix effects. These findings demonstrate a robust, sensitive, and user-friendly diagnostic strategy for field-based Mpox surveillance in resource-limited settings.</div></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"313 ","pages":"Article 130633"},"PeriodicalIF":6.7000,"publicationDate":"2027-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Disposable label-free electrochemical immunosensor using hollow porous gold sub-microcubes with surface-confined ferrocene for point-of-care detection of Mpox virus A29 protein\",\"authors\":\"Md Mahbubur Rahman Khan,&nbsp;Balamurugan Thangavel,&nbsp;Hyo-eun Kang,&nbsp;Joong Ho Shin\",\"doi\":\"10.1016/j.talanta.2026.130633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Monkeypox (Mpox), a viral zoonotic disease caused by the monkeypox virus (MPXV) remains a significant global public health concern. Current laboratory diagnostics are limited by high biosafety requirements and complex workflows, preventing point-of-care (POC) use. To address these limitations, a disposable, label-free electrochemical immunosensor was developed to detect the MPXV A29 glycoprotein, a highly immunogenic and diagnostically relevant protein. Shape-controlled, reproducible, hollow porous gold sub-microcubes (HPGCs) were synthesized using AgCl as a sacrificial template. The screen-printed carbon electrode was functionalized with poly-<span>l</span>-cysteine and HPGCs bearing a surface-confined 6-(ferrocenyl)hexanethiol probe and antibody for selective antigen binding. Antigen binding attenuates the ferrocene electrochemistry, investigated by voltammetry and impedance spectroscopy. The high surface-to-volume ratio and electrocatalytically active centers of HPGCs enable high loading of ferrocene and antibodies. The surface-confined signaling probe eliminates the need for an external signaling probe, offering a portable, reagent-free POC testing. The sensor offers a wide linear range (0.1–3200 ng/mL), low detection limit (0.1 ng/mL), excellent selectivity against non-target proteins, high reproducibility (RSD = 3.73%), and strong recovery in spiked serum with minimal matrix effects. These findings demonstrate a robust, sensitive, and user-friendly diagnostic strategy for field-based Mpox surveillance in resource-limited settings.</div></div>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"313 \",\"pages\":\"Article 130633\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2027-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0039914026012890\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/9/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914026012890","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

猴痘是一种由猴痘病毒(MPXV)引起的病毒性人畜共患疾病,仍然是一个重大的全球公共卫生问题。目前的实验室诊断受到高生物安全要求和复杂工作流程的限制,妨碍了护理点(POC)的使用。为了解决这些限制,我们开发了一种一次性的、无标签的电化学免疫传感器来检测MPXV A29糖蛋白,这是一种高度免疫原性和诊断相关的蛋白质。以AgCl为牺牲模板,合成了形状可控、可重复的中空多孔金亚微立方体(hpgc)。丝网印刷的碳电极用聚l-半胱氨酸和带有表面约束的6-(二茂铁)己硫醇探针和选择性抗原结合抗体的高效液相色谱进行功能化。用伏安法和阻抗谱法研究了抗原结合对二茂铁电化学的衰减作用。高表面体积比和电催化活性中心使二茂铁和抗体的高负载成为可能。表面受限的信号探头消除了外部信号探头的需要,提供了便携式、无试剂的POC测试。该传感器具有宽线性范围(0.1 - 3200 ng/mL),低检出限(0.1 ng/mL),对非靶蛋白具有良好的选择性,高重复性(RSD = 3.73%),在加标血清中具有很强的回收率,基质效应最小。这些发现表明,在资源有限的情况下,为基于现场的m痘监测提供了一种可靠、敏感和用户友好的诊断策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Disposable label-free electrochemical immunosensor using hollow porous gold sub-microcubes with surface-confined ferrocene for point-of-care detection of Mpox virus A29 protein
Monkeypox (Mpox), a viral zoonotic disease caused by the monkeypox virus (MPXV) remains a significant global public health concern. Current laboratory diagnostics are limited by high biosafety requirements and complex workflows, preventing point-of-care (POC) use. To address these limitations, a disposable, label-free electrochemical immunosensor was developed to detect the MPXV A29 glycoprotein, a highly immunogenic and diagnostically relevant protein. Shape-controlled, reproducible, hollow porous gold sub-microcubes (HPGCs) were synthesized using AgCl as a sacrificial template. The screen-printed carbon electrode was functionalized with poly-l-cysteine and HPGCs bearing a surface-confined 6-(ferrocenyl)hexanethiol probe and antibody for selective antigen binding. Antigen binding attenuates the ferrocene electrochemistry, investigated by voltammetry and impedance spectroscopy. The high surface-to-volume ratio and electrocatalytically active centers of HPGCs enable high loading of ferrocene and antibodies. The surface-confined signaling probe eliminates the need for an external signaling probe, offering a portable, reagent-free POC testing. The sensor offers a wide linear range (0.1–3200 ng/mL), low detection limit (0.1 ng/mL), excellent selectivity against non-target proteins, high reproducibility (RSD = 3.73%), and strong recovery in spiked serum with minimal matrix effects. These findings demonstrate a robust, sensitive, and user-friendly diagnostic strategy for field-based Mpox surveillance in resource-limited settings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书