{"title":"使用一种新的混合装置在圆锥角膜分期中建立角膜上皮像差测量的精确参考基准。","authors":"Yizhou Yang, Rui Ning, Siheng Li, Xinning Yang, Yiran Wang, Kexin Li, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinhai Huang","doi":"10.1186/s40662-026-00508-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).</p><p><strong>Methods: </strong>Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (S<sub>w</sub>), test-retest variability (TRT), and intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, S<sub>w</sub> and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The S<sub>w</sub> and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.</p><p><strong>Conclusions: </strong>The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"13 1","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2026-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13589856/pdf/","citationCount":"0","resultStr":"{\"title\":\"Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages.\",\"authors\":\"Yizhou Yang, Rui Ning, Siheng Li, Xinning Yang, Yiran Wang, Kexin Li, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinhai Huang\",\"doi\":\"10.1186/s40662-026-00508-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).</p><p><strong>Methods: </strong>Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (S<sub>w</sub>), test-retest variability (TRT), and intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, S<sub>w</sub> and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The S<sub>w</sub> and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.</p><p><strong>Conclusions: </strong>The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.</p>\",\"PeriodicalId\":12194,\"journal\":{\"name\":\"Eye and Vision\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":5.2000,\"publicationDate\":\"2026-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13589856/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-026-00508-x\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-026-00508-x","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages.
Background: To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).
Methods: Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (Sw), test-retest variability (TRT), and intraclass correlation coefficient (ICC).
Results: The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, Sw and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The Sw and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.
Conclusions: The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.
期刊介绍:
Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.