使用一种新的混合装置在圆锥角膜分期中建立角膜上皮像差测量的精确参考基准。

IF 5.2 1区 医学 Q1 OPHTHALMOLOGY
Yizhou Yang, Rui Ning, Siheng Li, Xinning Yang, Yiran Wang, Kexin Li, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinhai Huang
{"title":"使用一种新的混合装置在圆锥角膜分期中建立角膜上皮像差测量的精确参考基准。","authors":"Yizhou Yang, Rui Ning, Siheng Li, Xinning Yang, Yiran Wang, Kexin Li, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinhai Huang","doi":"10.1186/s40662-026-00508-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).</p><p><strong>Methods: </strong>Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (S<sub>w</sub>), test-retest variability (TRT), and intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, S<sub>w</sub> and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The S<sub>w</sub> and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.</p><p><strong>Conclusions: </strong>The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":"13 1","pages":""},"PeriodicalIF":5.2000,"publicationDate":"2026-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13589856/pdf/","citationCount":"0","resultStr":"{\"title\":\"Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages.\",\"authors\":\"Yizhou Yang, Rui Ning, Siheng Li, Xinning Yang, Yiran Wang, Kexin Li, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinhai Huang\",\"doi\":\"10.1186/s40662-026-00508-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).</p><p><strong>Methods: </strong>Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (S<sub>w</sub>), test-retest variability (TRT), and intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, S<sub>w</sub> and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The S<sub>w</sub> and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.</p><p><strong>Conclusions: </strong>The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.</p>\",\"PeriodicalId\":12194,\"journal\":{\"name\":\"Eye and Vision\",\"volume\":\"13 1\",\"pages\":\"\"},\"PeriodicalIF\":5.2000,\"publicationDate\":\"2026-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13589856/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye and Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-026-00508-x\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-026-00508-x","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:通过评估一种新型光谱域光学相干层析- placido磁盘装置(MS-39; CSO)的精度,为圆锥角膜(KC)不同阶段的角膜上皮像差测量建立精度参考基准。方法:将KC分为成形性挫裂性圆锥角膜(FFKC)、轻、中、重度病变阶段。两名熟练的操作人员用MS-39连续测量了三次角膜上皮像差。使用受试者内标准差(Sw)、重测变异性(TRT)和类内相关系数(ICC)评估观察者内重复性和观察者间重复性。结果:前瞻性研究纳入141名KC受试者的141只眼睛。FFKC亚组32只眼,轻度29只眼,中度45只眼,重度35只眼。FFKC组、轻度组、中度组和完全组的Sw和TRT的观察者内重复性分别为≤0.18 μm和≤0.50 μm。除三叶草和散光II外,其余参数的ICCs均≥0.884。观察者间再现性的Sw和TRT分别≤0.15 μm和≤0.41 μm。除三叶草和散光II外,ICCs均≥0.917。在重度组,观察者内重复性和观察者间重复性的ICCs分别为0.366 ~ 0.904和0.493 ~ 0.908。结论:新的MS-39设备在FFKC、轻度、中度和完全KC的角膜上皮畸变测量中表现出中等到良好的精度,尽管KC严重程度的增加会降低,但该设备在早期诊断和监测方面的潜力仍然很明显。仪器的精度应与疾病的严重程度相适应。针对上皮畸变测量的阶段特异性TRT阈值被提出用于KC管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Establishing a precision reference benchmark for corneal epithelial aberration measurements using a new hybrid device across keratoconus stages.

Background: To establish a precision reference benchmark for corneal epithelial aberration measurements across different stages of keratoconus (KC) by evaluating the precision of a new spectral-domain optical coherence tomography-Placido disk device (MS-39; CSO).

Methods: Eyes with KC were classified into forme fruste keratoconus (FFKC), mild, moderate, and severe disease stage. Three consecutive corneal epithelial aberration measurements were obtained with the MS-39 by two skilled operators. The intraobserver repeatability and interobserver reproducibility were evaluated using within-subject standard deviation (Sw), test-retest variability (TRT), and intraclass correlation coefficient (ICC).

Results: The prospective study enrolled 141 eyes from 141 KC subjects. Subgroups included 32 eyes with FFKC, 29 with mild, 45 with moderate, and 35 with severe KC. In the FFKC, mild, moderate, and total groups, Sw and TRT for intraobserver repeatability were ≤ 0.18 μm and ≤ 0.50 μm, respectively. ICCs were ≥ 0.884 for most parameters except trefoil and astigmatism II. The Sw and TRT for interobserver reproducibility were ≤ 0.15 μm and ≤ 0.41 μm, respectively. ICCs were ≥ 0.917 except for trefoil and astigmatism II. In the severe group, the ICCs for intraobserver repeatability and interobserver reproducibility were 0.366 to 0.904 and 0.493 to 0.908.

Conclusions: The new MS-39 device demonstrated moderate-to-good precision in corneal epithelial aberration measurements for FFKC, mild, moderate and total KC. Despite the decrease associated with increasing KC severity, the potential of the device for early diagnosis and monitoring was still evident. The instrument's precision should be tailored to disease severity. Stage-specific TRT thresholds for epithelial aberration measurements were proposed for KC management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书