用于荧光引导肺癌和乳腺癌手术的单芯片双增益彩色近红外相机

IF 24 Q1 OPTICS
Zhongmin Zhu, Brianna Hajek, Yifei Jin, Sinisha Stojanovski, Anamarija Jankulovska, Darko Angjushev, Igor Djikovski, Nexhati Jakupi, Risto Colanceski, Imran Ferati, Borce Antevski, Ilir Vela, Despot Despotovski, Natasha Tolevska Dimitrovska, Magdalena Bogdanovska Todorovska, Goran Kondov, Borislav Kondov, Shuming Nie, Sunil Singhal, Viktor Gruev
{"title":"用于荧光引导肺癌和乳腺癌手术的单芯片双增益彩色近红外相机","authors":"Zhongmin Zhu, Brianna Hajek, Yifei Jin, Sinisha Stojanovski, Anamarija Jankulovska, Darko Angjushev, Igor Djikovski, Nexhati Jakupi, Risto Colanceski, Imran Ferati, Borce Antevski, Ilir Vela, Despot Despotovski, Natasha Tolevska Dimitrovska, Magdalena Bogdanovska Todorovska, Goran Kondov, Borislav Kondov, Shuming Nie, Sunil Singhal, Viktor Gruev","doi":"10.1038/s41377-026-02437-9","DOIUrl":null,"url":null,"abstract":"Near infrared (NIR) fluorescence guided surgery can highlight tumors and sentinel lymph nodes, but most clinical fluorescence imaging systems use multi-camera architectures in which residual color–NIR misregistration can mislocalize fluorescence relative to anatomy, and weak signals often require dimming operating room lights. We developed a single-chip dual-gain scientific CMOS (sCMOS) sensor with red, green, blue (RGB), and NIR channels that provides intrinsically coregistered color reflectance and NIR fluorescence under typical operating room illumination (50–80 kLux). A backside illuminated array with division of focal plane (DoFP) pixelated interference filters achieves an input-referred read noise of 2.25 electrons and a fused dynamic range >90 dB, enabling indocyanine green (ICG) detection at ~100 pM under dark-background conditions and ~500 pM under standard 50–80 kLux operating-room illumination, with quantification over four orders of magnitude. We integrated the sensor into a surgical camera and evaluated it in 20 patients with lung cancer receiving the cathepsin-activated ICG probe VGT-309 and 35 patients with breast cancer undergoing ICG-guided sentinel lymph node biopsy. In lung cancer, lesion level sensitivity was 0.90 (18/20) and positive predictive value was 0.78 (18/23), with at least one clinically significant event in 45% (9/20) of patients. In breast cancer (90 specimens), high-gain NIR imaging improved classification of gamma probe-designated sentinel lymph nodes by node-to-background ratio (ROC AUC 0.94 vs 0.60) while preserving a white light view. These results establish a single-chip route to lights-on color and NIR guidance in the operating room.","PeriodicalId":18069,"journal":{"name":"Light-Science & Applications","volume":"19 1","pages":""},"PeriodicalIF":24.0000,"publicationDate":"2026-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A single-chip, dual-gain color–NIR camera for fluorescence-guided lung and breast cancer surgery\",\"authors\":\"Zhongmin Zhu, Brianna Hajek, Yifei Jin, Sinisha Stojanovski, Anamarija Jankulovska, Darko Angjushev, Igor Djikovski, Nexhati Jakupi, Risto Colanceski, Imran Ferati, Borce Antevski, Ilir Vela, Despot Despotovski, Natasha Tolevska Dimitrovska, Magdalena Bogdanovska Todorovska, Goran Kondov, Borislav Kondov, Shuming Nie, Sunil Singhal, Viktor Gruev\",\"doi\":\"10.1038/s41377-026-02437-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Near infrared (NIR) fluorescence guided surgery can highlight tumors and sentinel lymph nodes, but most clinical fluorescence imaging systems use multi-camera architectures in which residual color–NIR misregistration can mislocalize fluorescence relative to anatomy, and weak signals often require dimming operating room lights. We developed a single-chip dual-gain scientific CMOS (sCMOS) sensor with red, green, blue (RGB), and NIR channels that provides intrinsically coregistered color reflectance and NIR fluorescence under typical operating room illumination (50–80 kLux). A backside illuminated array with division of focal plane (DoFP) pixelated interference filters achieves an input-referred read noise of 2.25 electrons and a fused dynamic range >90 dB, enabling indocyanine green (ICG) detection at ~100 pM under dark-background conditions and ~500 pM under standard 50–80 kLux operating-room illumination, with quantification over four orders of magnitude. We integrated the sensor into a surgical camera and evaluated it in 20 patients with lung cancer receiving the cathepsin-activated ICG probe VGT-309 and 35 patients with breast cancer undergoing ICG-guided sentinel lymph node biopsy. In lung cancer, lesion level sensitivity was 0.90 (18/20) and positive predictive value was 0.78 (18/23), with at least one clinically significant event in 45% (9/20) of patients. In breast cancer (90 specimens), high-gain NIR imaging improved classification of gamma probe-designated sentinel lymph nodes by node-to-background ratio (ROC AUC 0.94 vs 0.60) while preserving a white light view. These results establish a single-chip route to lights-on color and NIR guidance in the operating room.\",\"PeriodicalId\":18069,\"journal\":{\"name\":\"Light-Science & Applications\",\"volume\":\"19 1\",\"pages\":\"\"},\"PeriodicalIF\":24.0000,\"publicationDate\":\"2026-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Light-Science & Applications\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1038/s41377-026-02437-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Light-Science & Applications","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1038/s41377-026-02437-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

摘要

近红外(NIR)荧光引导手术可以突出肿瘤和前哨淋巴结,但大多数临床荧光成像系统使用多摄像头架构,其中残留的颜色-近红外错配可能导致荧光相对于解剖结构的错误定位,并且微弱的信号通常需要调暗手术室的灯光。我们开发了一种单芯片双增益科学CMOS (sCMOS)传感器,具有红、绿、蓝(RGB)和近红外通道,在典型的手术室照明(50-80 kLux)下提供本质上共配的颜色反射率和近红外荧光。带有焦平面分割(DoFP)像素化干扰滤光片的背面照明阵列实现了2.25个电子的输入参考读噪声和> ~ 90db的融合动态范围,在暗背景条件下~ 100pm和标准50-80 kLux手术室照明下~ 500pm的吲哚青绿(ICG)检测,量化超过4个数量级。我们将传感器集成到手术相机中,并在20例接受组织蛋白酶激活ICG探针VGT-309的肺癌患者和35例接受ICG引导前哨淋巴结活检的乳腺癌患者中对其进行了评估。在肺癌中,病变水平敏感性为0.90(18/20),阳性预测值为0.78(18/23),45%(9/20)的患者至少有一次临床显著事件。在乳腺癌(90个标本)中,高增益近红外成像在保留白光视图的同时,通过淋巴结与背景比(ROC AUC 0.94 vs 0.60)改善了γ探针指定的前哨淋巴结的分类。这些结果建立了一种在手术室中实现亮灯和近红外引导的单芯片路线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A single-chip, dual-gain color–NIR camera for fluorescence-guided lung and breast cancer surgery

A single-chip, dual-gain color–NIR camera for fluorescence-guided lung and breast cancer surgery
Near infrared (NIR) fluorescence guided surgery can highlight tumors and sentinel lymph nodes, but most clinical fluorescence imaging systems use multi-camera architectures in which residual color–NIR misregistration can mislocalize fluorescence relative to anatomy, and weak signals often require dimming operating room lights. We developed a single-chip dual-gain scientific CMOS (sCMOS) sensor with red, green, blue (RGB), and NIR channels that provides intrinsically coregistered color reflectance and NIR fluorescence under typical operating room illumination (50–80 kLux). A backside illuminated array with division of focal plane (DoFP) pixelated interference filters achieves an input-referred read noise of 2.25 electrons and a fused dynamic range >90 dB, enabling indocyanine green (ICG) detection at ~100 pM under dark-background conditions and ~500 pM under standard 50–80 kLux operating-room illumination, with quantification over four orders of magnitude. We integrated the sensor into a surgical camera and evaluated it in 20 patients with lung cancer receiving the cathepsin-activated ICG probe VGT-309 and 35 patients with breast cancer undergoing ICG-guided sentinel lymph node biopsy. In lung cancer, lesion level sensitivity was 0.90 (18/20) and positive predictive value was 0.78 (18/23), with at least one clinically significant event in 45% (9/20) of patients. In breast cancer (90 specimens), high-gain NIR imaging improved classification of gamma probe-designated sentinel lymph nodes by node-to-background ratio (ROC AUC 0.94 vs 0.60) while preserving a white light view. These results establish a single-chip route to lights-on color and NIR guidance in the operating room.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Light-Science & Applications
Light-Science & Applications 数理科学, 物理学I, 光学, 凝聚态物性 II :电子结构、电学、磁学和光学性质, 无机非金属材料, 无机非金属类光电信息与功能材料, 工程与材料, 信息科学, 光学和光电子学, 光学和光电子材料, 非线性光学与量子光学
自引率
0.00%
发文量
803
审稿时长
2.1 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书