Cu@Fe2O3复合修饰电极吸附调控电化学测定17α-炔雌醇。

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Talanta Pub Date : 2027-02-01 Epub Date: 2026-08-08 DOI:10.1016/j.talanta.2026.130407
Meng Li, Xiaowei Yang, Liwei Yang, Huiping Bai, Fengzhi Jiang
{"title":"Cu@Fe2O3复合修饰电极吸附调控电化学测定17α-炔雌醇。","authors":"Meng Li, Xiaowei Yang, Liwei Yang, Huiping Bai, Fengzhi Jiang","doi":"10.1016/j.talanta.2026.130407","DOIUrl":null,"url":null,"abstract":"<p><p>17α-Ethinylestradiol (EE2) is a phenolic estrogenic endocrine disruptor widely distributed in aquatic environments; therefore, sensitive and reliable analytical methods for its environmental monitoring are required. Herein, an adsorption-regulated electrochemical sensing strategy is proposed for the quantitative determination of EE2 using a Cu@Fe<sub>2</sub>O<sub>3</sub> composite-modified glassy carbon electrode. The synergistic Cu-Fe<sub>2</sub>O<sub>3</sub> interface effectively enhances interfacial affinity toward EE2 molecules and facilitates proton-coupled electron transfer during electrochemical oxidation, resulting in an analytical signal predominantly governed by interfacial adsorption rather than diffusion. Under optimized conditions, the modified electrode exhibits a good linear response to EE2 in the concentration range of 0.10 -20.00 μM with a detection limit of 0.033 μM. Electrochemical mechanism studies indicate that the oxidation of EE2 is an irreversible, adsorption-controlled process. The proposed sensor shows satisfactory selectivity, good repeatability, and long-term stability. Moreover, it was successfully applied to the determination of EE2 in real water samples with acceptable recovery values. This study highlights the crucial role of interfacial adsorption in electrochemical signal amplification and provides a versatile analytical strategy for the sensitive detection of phenolic endocrine-disrupting compounds in complex water matrices.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"312 Pt A","pages":"130407"},"PeriodicalIF":6.7000,"publicationDate":"2027-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adsorption-regulated electrochemical determination of 17α-ethinylestradiol based on a Cu@Fe<sub>2</sub>O<sub>3</sub> composite-modified electrode.\",\"authors\":\"Meng Li, Xiaowei Yang, Liwei Yang, Huiping Bai, Fengzhi Jiang\",\"doi\":\"10.1016/j.talanta.2026.130407\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>17α-Ethinylestradiol (EE2) is a phenolic estrogenic endocrine disruptor widely distributed in aquatic environments; therefore, sensitive and reliable analytical methods for its environmental monitoring are required. Herein, an adsorption-regulated electrochemical sensing strategy is proposed for the quantitative determination of EE2 using a Cu@Fe<sub>2</sub>O<sub>3</sub> composite-modified glassy carbon electrode. The synergistic Cu-Fe<sub>2</sub>O<sub>3</sub> interface effectively enhances interfacial affinity toward EE2 molecules and facilitates proton-coupled electron transfer during electrochemical oxidation, resulting in an analytical signal predominantly governed by interfacial adsorption rather than diffusion. Under optimized conditions, the modified electrode exhibits a good linear response to EE2 in the concentration range of 0.10 -20.00 μM with a detection limit of 0.033 μM. Electrochemical mechanism studies indicate that the oxidation of EE2 is an irreversible, adsorption-controlled process. The proposed sensor shows satisfactory selectivity, good repeatability, and long-term stability. Moreover, it was successfully applied to the determination of EE2 in real water samples with acceptable recovery values. This study highlights the crucial role of interfacial adsorption in electrochemical signal amplification and provides a versatile analytical strategy for the sensitive detection of phenolic endocrine-disrupting compounds in complex water matrices.</p>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"312 Pt A\",\"pages\":\"130407\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2027-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.talanta.2026.130407\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2026.130407","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

17α-炔雌醇(EE2)是一种广泛存在于水生环境中的酚类雌激素内分泌干扰物;因此,需要一种灵敏、可靠的环境监测分析方法。本文提出了一种吸附调节电化学传感策略,用于Cu@Fe2O3复合修饰玻碳电极对EE2的定量测定。Cu-Fe2O3的协同界面有效地增强了界面对EE2分子的亲和力,促进了电化学氧化过程中质子耦合电子的转移,导致分析信号主要受界面吸附而不是扩散控制。在优化条件下,电极对EE2在0.10 ~ 20.00 μM的浓度范围内具有良好的线性响应,检出限为0.033 μM。电化学机理研究表明,EE2的氧化是一个不可逆的吸附控制过程。该传感器具有良好的选择性、重复性和长期稳定性。并成功应用于实际水样中EE2的测定,回收率可接受。本研究强调了界面吸附在电化学信号放大中的关键作用,并为复杂水基质中酚类内分泌干扰化合物的灵敏检测提供了一种通用的分析策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adsorption-regulated electrochemical determination of 17α-ethinylestradiol based on a Cu@Fe2O3 composite-modified electrode.

17α-Ethinylestradiol (EE2) is a phenolic estrogenic endocrine disruptor widely distributed in aquatic environments; therefore, sensitive and reliable analytical methods for its environmental monitoring are required. Herein, an adsorption-regulated electrochemical sensing strategy is proposed for the quantitative determination of EE2 using a Cu@Fe2O3 composite-modified glassy carbon electrode. The synergistic Cu-Fe2O3 interface effectively enhances interfacial affinity toward EE2 molecules and facilitates proton-coupled electron transfer during electrochemical oxidation, resulting in an analytical signal predominantly governed by interfacial adsorption rather than diffusion. Under optimized conditions, the modified electrode exhibits a good linear response to EE2 in the concentration range of 0.10 -20.00 μM with a detection limit of 0.033 μM. Electrochemical mechanism studies indicate that the oxidation of EE2 is an irreversible, adsorption-controlled process. The proposed sensor shows satisfactory selectivity, good repeatability, and long-term stability. Moreover, it was successfully applied to the determination of EE2 in real water samples with acceptable recovery values. This study highlights the crucial role of interfacial adsorption in electrochemical signal amplification and provides a versatile analytical strategy for the sensitive detection of phenolic endocrine-disrupting compounds in complex water matrices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书