Masoumeh Mortazavikhah, Abdulrahman Bahrami, Abbas Farmany, Ali Poormohammadi, Farshid Ghorbani Shahna, Javad Faradmal, Majid Habibi Mohraz
{"title":"针阱装置填充CS@GO气凝胶,用于分析空气中的多环芳烃。","authors":"Masoumeh Mortazavikhah, Abdulrahman Bahrami, Abbas Farmany, Ali Poormohammadi, Farshid Ghorbani Shahna, Javad Faradmal, Majid Habibi Mohraz","doi":"10.1007/s40201-026-00997-x","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, chitosan/graphene oxide aerogel (CS@GOA) was synthesized using a modified route of graphene oxide (GO) synthesis. The adsorbent was packed into a needle trap (NTD), introducing a novel solvent-free sampling method with direct thermal desorptionfor the analysis of polycyclic aromatic compounds (PAHs) in air. The quantitative characteristics of CS@GOA were specified using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). The performance of the method was evaluated under both laboratory and field conditions, after assessing parameters like storage time, carryover effect, repeatability and reproducibility of the NTD. The optimization of injection parameters, including time and temperature, was performed using Response Surface Methodology (RSM) and Central Composite Design (CCD). The method exhibited high sensitivity with limits of detection (LOD) and quantification (LOQ) ranging from 0.0004 to 0.018 ng mL<sup>−1</sup> and 0.0012 to 0.06 ng mL<sup>−1</sup>, respectively. Repeatability and reproducibility of the method were obtained within the ranges of 1.5–8.74% and 2.8–14%, respectively. A correlation of R<sup>2</sup>: 0.89–0.99 was obtained between the proposed method and the National Institute for Occupational Safety and Health (NIOSH-5515) method. The chitosan/graphene oxide aerogel-packed needle found to be an affordable, easy, and reliable method for direct detection of PAHs without solvent extraction in real field samples outperforming the NIOSH method.</p></div>","PeriodicalId":628,"journal":{"name":"Journal of Environmental Health Science and Engineering","volume":"24 2","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2026-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Needle trap device packed with CS@GO aerogel for analysis of polycyclic aromatic hydrocarbons in air\",\"authors\":\"Masoumeh Mortazavikhah, Abdulrahman Bahrami, Abbas Farmany, Ali Poormohammadi, Farshid Ghorbani Shahna, Javad Faradmal, Majid Habibi Mohraz\",\"doi\":\"10.1007/s40201-026-00997-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, chitosan/graphene oxide aerogel (CS@GOA) was synthesized using a modified route of graphene oxide (GO) synthesis. The adsorbent was packed into a needle trap (NTD), introducing a novel solvent-free sampling method with direct thermal desorptionfor the analysis of polycyclic aromatic compounds (PAHs) in air. The quantitative characteristics of CS@GOA were specified using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). The performance of the method was evaluated under both laboratory and field conditions, after assessing parameters like storage time, carryover effect, repeatability and reproducibility of the NTD. The optimization of injection parameters, including time and temperature, was performed using Response Surface Methodology (RSM) and Central Composite Design (CCD). The method exhibited high sensitivity with limits of detection (LOD) and quantification (LOQ) ranging from 0.0004 to 0.018 ng mL<sup>−1</sup> and 0.0012 to 0.06 ng mL<sup>−1</sup>, respectively. Repeatability and reproducibility of the method were obtained within the ranges of 1.5–8.74% and 2.8–14%, respectively. A correlation of R<sup>2</sup>: 0.89–0.99 was obtained between the proposed method and the National Institute for Occupational Safety and Health (NIOSH-5515) method. The chitosan/graphene oxide aerogel-packed needle found to be an affordable, easy, and reliable method for direct detection of PAHs without solvent extraction in real field samples outperforming the NIOSH method.</p></div>\",\"PeriodicalId\":628,\"journal\":{\"name\":\"Journal of Environmental Health Science and Engineering\",\"volume\":\"24 2\",\"pages\":\"\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2026-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Health Science and Engineering\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s40201-026-00997-x\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Health Science and Engineering","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s40201-026-00997-x","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
摘要
本研究采用改性氧化石墨烯(GO)合成路线合成了壳聚糖/氧化石墨烯气凝胶(CS@GOA)。将吸附剂包装在针状捕集器(NTD)中,引入了一种新的无溶剂直接热解吸取样方法,用于分析空气中的多环芳烃(PAHs)。利用傅里叶变换红外光谱(FTIR)、扫描电镜(SEM)、能量色散x射线光谱(EDX)和x射线衍射(XRD)确定了CS@GOA的定量特征。在实验室和现场条件下,通过评估NTD的储存时间、携带效应、可重复性和再现性等参数,对该方法的性能进行了评估。采用响应面法(RSM)和中心复合设计(CCD)对注射时间和温度等参数进行了优化。方法灵敏度高,检出限(LOD)为0.0004 ~ 0.018 ng mL-1,定量限(LOQ)为0.0012 ~ 0.06 ng mL-1。方法的重复性和重现性分别在1.5 ~ 8.74%和2.8 ~ 14%范围内。该方法与美国国家职业安全与卫生研究所(NIOSH-5515)方法的相关系数为R2: 0.89-0.99。壳聚糖/氧化石墨烯气凝胶填充针是一种经济、简单、可靠的直接检测多环芳烃的方法,无需溶剂提取,在实际现场样品中优于NIOSH方法。
Needle trap device packed with CS@GO aerogel for analysis of polycyclic aromatic hydrocarbons in air
In this study, chitosan/graphene oxide aerogel (CS@GOA) was synthesized using a modified route of graphene oxide (GO) synthesis. The adsorbent was packed into a needle trap (NTD), introducing a novel solvent-free sampling method with direct thermal desorptionfor the analysis of polycyclic aromatic compounds (PAHs) in air. The quantitative characteristics of CS@GOA were specified using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). The performance of the method was evaluated under both laboratory and field conditions, after assessing parameters like storage time, carryover effect, repeatability and reproducibility of the NTD. The optimization of injection parameters, including time and temperature, was performed using Response Surface Methodology (RSM) and Central Composite Design (CCD). The method exhibited high sensitivity with limits of detection (LOD) and quantification (LOQ) ranging from 0.0004 to 0.018 ng mL−1 and 0.0012 to 0.06 ng mL−1, respectively. Repeatability and reproducibility of the method were obtained within the ranges of 1.5–8.74% and 2.8–14%, respectively. A correlation of R2: 0.89–0.99 was obtained between the proposed method and the National Institute for Occupational Safety and Health (NIOSH-5515) method. The chitosan/graphene oxide aerogel-packed needle found to be an affordable, easy, and reliable method for direct detection of PAHs without solvent extraction in real field samples outperforming the NIOSH method.
期刊介绍:
Journal of Environmental Health Science & Engineering is a peer-reviewed journal presenting timely research on all aspects of environmental health science, engineering and management.
A broad outline of the journal''s scope includes:
-Water pollution and treatment
-Wastewater treatment and reuse
-Air control
-Soil remediation
-Noise and radiation control
-Environmental biotechnology and nanotechnology
-Food safety and hygiene