{"title":"乏燃料溶解过程中放射性气溶胶多参数同步检测技术研究。","authors":"Yongzhen Xia, Runjie Di, Yongji Xie, Xin Wang","doi":"10.1097/HP.0000000000002141","DOIUrl":null,"url":null,"abstract":"<p><p>Spent-fuel dissolution produces multi-nuclide, high-activity aerosols. Gross α/β CAMs are prone to interference and slow response, limiting timely dose assessment and alarms. We developed an integrated multiparameter synchronous detection system to simultaneously measure activity concentration, spectra, and particle size. The instrument integrates sampling and optical sizing (0.1-10 μm) with a silicon barrier (α), thin-window proportional (β), and 2 × 2 NaI (Tl) (γ) detectors. Signals are digitized (14-bit/100 MS s -1 ) for pulse-shape discrimination and 8,192-channel spectrometry. Performance followed ISO 11929/Currie. Standard sources and mixed-nuclide aerosols were used for calibration, linearity, response, and misclassification tests; stability was assessed over 720 h (50 L min -1 , 60 s integration). Detection efficiencies were 26.3% ( 241 Am α), 42.5% ( 90 Sr/ 90 Y β), and 31.2% ( 137 Cs γ). Minimum detectable activities were 8.5 × 10 -7 Bq cm -3 ( 241 Am), 9.2 × 10 -7 Bq cm -3 ( 239 Pu), and 3.1 × 10 -6 Bq cm -1 ( 90 Sr/ 90 Y). Dynamic tests gave T 90 = 17.5 s and T 95 = 22.3 s; α/β misclassification < 5%; linearity across five orders (R 2 = 0.9987). Compared with a representative CAM, spectral resolving power improved ≈5-fold and response time shortened 10-20 times. Energy and efficiency drift over 720 h were ≤±2% and ≤±3%. Multi-parameter acquisition reduces dose-assessment bias from nuclide misidentification and size assumptions and shortens alarm latency to < 30 s in high-background, multi-nuclide environments, supporting ALARA and process control during spent-fuel dissolution.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":" ","pages":"482-495"},"PeriodicalIF":1.2000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Multi-parameter Synchronous Detection Technology for Radioactive Aerosols in Spent Fuel Dissolution Process.\",\"authors\":\"Yongzhen Xia, Runjie Di, Yongji Xie, Xin Wang\",\"doi\":\"10.1097/HP.0000000000002141\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Spent-fuel dissolution produces multi-nuclide, high-activity aerosols. Gross α/β CAMs are prone to interference and slow response, limiting timely dose assessment and alarms. We developed an integrated multiparameter synchronous detection system to simultaneously measure activity concentration, spectra, and particle size. The instrument integrates sampling and optical sizing (0.1-10 μm) with a silicon barrier (α), thin-window proportional (β), and 2 × 2 NaI (Tl) (γ) detectors. Signals are digitized (14-bit/100 MS s -1 ) for pulse-shape discrimination and 8,192-channel spectrometry. Performance followed ISO 11929/Currie. Standard sources and mixed-nuclide aerosols were used for calibration, linearity, response, and misclassification tests; stability was assessed over 720 h (50 L min -1 , 60 s integration). Detection efficiencies were 26.3% ( 241 Am α), 42.5% ( 90 Sr/ 90 Y β), and 31.2% ( 137 Cs γ). Minimum detectable activities were 8.5 × 10 -7 Bq cm -3 ( 241 Am), 9.2 × 10 -7 Bq cm -3 ( 239 Pu), and 3.1 × 10 -6 Bq cm -1 ( 90 Sr/ 90 Y). Dynamic tests gave T 90 = 17.5 s and T 95 = 22.3 s; α/β misclassification < 5%; linearity across five orders (R 2 = 0.9987). Compared with a representative CAM, spectral resolving power improved ≈5-fold and response time shortened 10-20 times. Energy and efficiency drift over 720 h were ≤±2% and ≤±3%. Multi-parameter acquisition reduces dose-assessment bias from nuclide misidentification and size assumptions and shortens alarm latency to < 30 s in high-background, multi-nuclide environments, supporting ALARA and process control during spent-fuel dissolution.</p>\",\"PeriodicalId\":12976,\"journal\":{\"name\":\"Health physics\",\"volume\":\" \",\"pages\":\"482-495\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2026-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Health physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HP.0000000000002141\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/8/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000002141","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Investigation of Multi-parameter Synchronous Detection Technology for Radioactive Aerosols in Spent Fuel Dissolution Process.
Spent-fuel dissolution produces multi-nuclide, high-activity aerosols. Gross α/β CAMs are prone to interference and slow response, limiting timely dose assessment and alarms. We developed an integrated multiparameter synchronous detection system to simultaneously measure activity concentration, spectra, and particle size. The instrument integrates sampling and optical sizing (0.1-10 μm) with a silicon barrier (α), thin-window proportional (β), and 2 × 2 NaI (Tl) (γ) detectors. Signals are digitized (14-bit/100 MS s -1 ) for pulse-shape discrimination and 8,192-channel spectrometry. Performance followed ISO 11929/Currie. Standard sources and mixed-nuclide aerosols were used for calibration, linearity, response, and misclassification tests; stability was assessed over 720 h (50 L min -1 , 60 s integration). Detection efficiencies were 26.3% ( 241 Am α), 42.5% ( 90 Sr/ 90 Y β), and 31.2% ( 137 Cs γ). Minimum detectable activities were 8.5 × 10 -7 Bq cm -3 ( 241 Am), 9.2 × 10 -7 Bq cm -3 ( 239 Pu), and 3.1 × 10 -6 Bq cm -1 ( 90 Sr/ 90 Y). Dynamic tests gave T 90 = 17.5 s and T 95 = 22.3 s; α/β misclassification < 5%; linearity across five orders (R 2 = 0.9987). Compared with a representative CAM, spectral resolving power improved ≈5-fold and response time shortened 10-20 times. Energy and efficiency drift over 720 h were ≤±2% and ≤±3%. Multi-parameter acquisition reduces dose-assessment bias from nuclide misidentification and size assumptions and shortens alarm latency to < 30 s in high-background, multi-nuclide environments, supporting ALARA and process control during spent-fuel dissolution.
期刊介绍:
Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.