Sydney Kaplan, Zexuan Liu, Jesse Hamilton, Shaihan Malik, Chaitanya Madamanchi, Venkatesh Murthy, Scott Swanson, Nicole Seiberlich
{"title":"用常规心脏MRF和mt -心脏MRF估计的组织特性值的比较。","authors":"Sydney Kaplan, Zexuan Liu, Jesse Hamilton, Shaihan Malik, Chaitanya Madamanchi, Venkatesh Murthy, Scott Swanson, Nicole Seiberlich","doi":"10.1002/mrm.70470","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the impact of explicitly modeling Magnetization Transfer (MT) during reconstruction of cardiac Magnetic Resonance Fingerprinting (cMRF) maps on T<sub>1</sub> and T<sub>2</sub> quantification.</p><p><strong>Methods: </strong>cMRF data were reconstructed using two dictionaries: a conventional cMRF dictionary that ignores MT processes, and an MT-cMRF dictionary modeling T<sub>1</sub> and T<sub>2</sub> of the free water pool (T<sub>1f</sub> and T<sub>2f</sub>, respectively), as well as the bound pool fraction (BPF) as free parameters. Measurements which include MT processes were assessed in simulation and phantom to ensure that T<sub>1f</sub>, T<sub>2f</sub>, and BPF could accurately be measured using cMRF. cMRF data were then collected in 14 healthy subjects to measure T<sub>1</sub>/T<sub>1f</sub>, T<sub>2</sub>/T<sub>2f</sub>, and BPF in normal myocardium. Finally, cMRF data were acquired in five patients with known or suspected myocardial scar at 1.5T, and tissue property maps both ignoring and including MT were generated. Linear discriminant analyses (LDA) were performed to assess differences in tissue property values between scar and remote myocardium.</p><p><strong>Results: </strong>MT-cMRF showed excellent agreement with ground truth simulations (RMS error = 2.4% ± 3.9%) and phantom measurements (R<sup>2</sup> = 0.99). Values measured with MT-cMRF in healthy subjects (T<sub>1f</sub> = 1137 ± 72 ms, T<sub>2f</sub> = 42.8 ± 4.2 ms, BPF = 8.2% ± 1.2%) were significantly different than conventional cMRF (T<sub>1</sub> = 947 ± 75 ms, T<sub>2</sub> = 41.5 ± 3.9 ms). T<sub>1f</sub>/T<sub>2f</sub> and T<sub>2f</sub>/BPF from MT-cMRF demonstrated higher LDA accuracy (82.4% and 86.1%) in discriminating scar from healthy tissue than T<sub>1</sub> and T<sub>2</sub> from conventional cMRF (61.8%).</p><p><strong>Conclusion: </strong>Incorporating MT modeling into cMRF results in improved T<sub>1f</sub> and T<sub>2f</sub> quantification compared to conventional modeling and enables BPF measurement. Native MT-cMRF T<sub>1f</sub>, T<sub>2f</sub>, and BPF values showed differences between scar and healthy myocardium.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":"1806-1813"},"PeriodicalIF":3.2000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13419325/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.\",\"authors\":\"Sydney Kaplan, Zexuan Liu, Jesse Hamilton, Shaihan Malik, Chaitanya Madamanchi, Venkatesh Murthy, Scott Swanson, Nicole Seiberlich\",\"doi\":\"10.1002/mrm.70470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the impact of explicitly modeling Magnetization Transfer (MT) during reconstruction of cardiac Magnetic Resonance Fingerprinting (cMRF) maps on T<sub>1</sub> and T<sub>2</sub> quantification.</p><p><strong>Methods: </strong>cMRF data were reconstructed using two dictionaries: a conventional cMRF dictionary that ignores MT processes, and an MT-cMRF dictionary modeling T<sub>1</sub> and T<sub>2</sub> of the free water pool (T<sub>1f</sub> and T<sub>2f</sub>, respectively), as well as the bound pool fraction (BPF) as free parameters. Measurements which include MT processes were assessed in simulation and phantom to ensure that T<sub>1f</sub>, T<sub>2f</sub>, and BPF could accurately be measured using cMRF. cMRF data were then collected in 14 healthy subjects to measure T<sub>1</sub>/T<sub>1f</sub>, T<sub>2</sub>/T<sub>2f</sub>, and BPF in normal myocardium. Finally, cMRF data were acquired in five patients with known or suspected myocardial scar at 1.5T, and tissue property maps both ignoring and including MT were generated. Linear discriminant analyses (LDA) were performed to assess differences in tissue property values between scar and remote myocardium.</p><p><strong>Results: </strong>MT-cMRF showed excellent agreement with ground truth simulations (RMS error = 2.4% ± 3.9%) and phantom measurements (R<sup>2</sup> = 0.99). Values measured with MT-cMRF in healthy subjects (T<sub>1f</sub> = 1137 ± 72 ms, T<sub>2f</sub> = 42.8 ± 4.2 ms, BPF = 8.2% ± 1.2%) were significantly different than conventional cMRF (T<sub>1</sub> = 947 ± 75 ms, T<sub>2</sub> = 41.5 ± 3.9 ms). T<sub>1f</sub>/T<sub>2f</sub> and T<sub>2f</sub>/BPF from MT-cMRF demonstrated higher LDA accuracy (82.4% and 86.1%) in discriminating scar from healthy tissue than T<sub>1</sub> and T<sub>2</sub> from conventional cMRF (61.8%).</p><p><strong>Conclusion: </strong>Incorporating MT modeling into cMRF results in improved T<sub>1f</sub> and T<sub>2f</sub> quantification compared to conventional modeling and enables BPF measurement. Native MT-cMRF T<sub>1f</sub>, T<sub>2f</sub>, and BPF values showed differences between scar and healthy myocardium.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"1806-1813\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2026-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13419325/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/mrm.70470\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/7/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.70470","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.
Purpose: To evaluate the impact of explicitly modeling Magnetization Transfer (MT) during reconstruction of cardiac Magnetic Resonance Fingerprinting (cMRF) maps on T1 and T2 quantification.
Methods: cMRF data were reconstructed using two dictionaries: a conventional cMRF dictionary that ignores MT processes, and an MT-cMRF dictionary modeling T1 and T2 of the free water pool (T1f and T2f, respectively), as well as the bound pool fraction (BPF) as free parameters. Measurements which include MT processes were assessed in simulation and phantom to ensure that T1f, T2f, and BPF could accurately be measured using cMRF. cMRF data were then collected in 14 healthy subjects to measure T1/T1f, T2/T2f, and BPF in normal myocardium. Finally, cMRF data were acquired in five patients with known or suspected myocardial scar at 1.5T, and tissue property maps both ignoring and including MT were generated. Linear discriminant analyses (LDA) were performed to assess differences in tissue property values between scar and remote myocardium.
Results: MT-cMRF showed excellent agreement with ground truth simulations (RMS error = 2.4% ± 3.9%) and phantom measurements (R2 = 0.99). Values measured with MT-cMRF in healthy subjects (T1f = 1137 ± 72 ms, T2f = 42.8 ± 4.2 ms, BPF = 8.2% ± 1.2%) were significantly different than conventional cMRF (T1 = 947 ± 75 ms, T2 = 41.5 ± 3.9 ms). T1f/T2f and T2f/BPF from MT-cMRF demonstrated higher LDA accuracy (82.4% and 86.1%) in discriminating scar from healthy tissue than T1 and T2 from conventional cMRF (61.8%).
Conclusion: Incorporating MT modeling into cMRF results in improved T1f and T2f quantification compared to conventional modeling and enables BPF measurement. Native MT-cMRF T1f, T2f, and BPF values showed differences between scar and healthy myocardium.
期刊介绍:
Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.