样品制备历史对同位素分馏的影响:SRM 981铅的同位素比值

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Axel Pramann, Anita Röthke and Olaf Rienitz
{"title":"样品制备历史对同位素分馏的影响:SRM 981铅的同位素比值","authors":"Axel Pramann, Anita Röthke and Olaf Rienitz","doi":"10.1039/D6JA00106H","DOIUrl":null,"url":null,"abstract":"<p >Several batches of NIST SRM 981 dissolved in 0.15 mol kg<small><sup>−1</sup></small> HNO<small><sub>3</sub></small> were used for the determination of <em>K</em> factors of isotope ratios <small><sup>204</sup></small>Pb/<small><sup>208</sup></small>Pb, <small><sup>206</sup></small>Pb/<small><sup>208</sup></small>Pb, and <small><sup>207</sup></small>Pb/<small><sup>208</sup></small>Pb applying MC-ICP-MS. Pure solutions of the primary standard (reference) material NIST SRM 981 (<em>w</em>(Pb) ≈ 70 ng g<small><sup>−1</sup></small> to 100 ng g<small><sup>−1</sup></small>) were compared with those treated with a chromatographic separation using a crown ether resin, and additionally with those treated with microwave digestion followed by chromatographic separation. The procedural blank influence was studied and potential interferences of <small><sup>204</sup></small>Hg on the <small><sup>204</sup></small>Pb signal were corrected. An improved chromatographic separation protocol demonstrates the suitability of Pb separation. Mass bias correction factors (<em>K</em> factors) were determined for each ratio and compared for the three procedures. The respective uncertainty budgets for the first time gave direct quantitative indications of differences and uncertainty contributions of the respective digestion and column separation processes compared to untreated solutions. To derive the impact of the preparation steps alone (digestion, column separation), pure SRM® solutions with Pb (no Pb containing matrix samples) were investigated. For <em>K</em>(<small><sup>204</sup></small>Pb/<small><sup>208</sup></small>Pb) an impact of a sample pretreatment cannot be observed and isotopic fractionation can be mainly deduced from the mass spectrometric measurement. In case of the ratios <small><sup>206</sup></small>Pb/<small><sup>208</sup></small>Pb and <small><sup>207</sup></small>Pb/<small><sup>208</sup></small>Pb, the <em>K</em> factors of the digested and column separated as well as only column separated samples can be distinguished from the non-pretreated samples for <em>k</em> = 1, which suggests a small, but observable impact of the sample history on the <em>K</em> factor although the initial samples were matrix-free.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 6","pages":" 2263-2272"},"PeriodicalIF":3.3000,"publicationDate":"2026-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d6ja00106h?page=search","citationCount":"0","resultStr":"{\"title\":\"Impact of sample preparation history on isotopic fractionation: isotope ratios of lead SRM 981\",\"authors\":\"Axel Pramann, Anita Röthke and Olaf Rienitz\",\"doi\":\"10.1039/D6JA00106H\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Several batches of NIST SRM 981 dissolved in 0.15 mol kg<small><sup>−1</sup></small> HNO<small><sub>3</sub></small> were used for the determination of <em>K</em> factors of isotope ratios <small><sup>204</sup></small>Pb/<small><sup>208</sup></small>Pb, <small><sup>206</sup></small>Pb/<small><sup>208</sup></small>Pb, and <small><sup>207</sup></small>Pb/<small><sup>208</sup></small>Pb applying MC-ICP-MS. Pure solutions of the primary standard (reference) material NIST SRM 981 (<em>w</em>(Pb) ≈ 70 ng g<small><sup>−1</sup></small> to 100 ng g<small><sup>−1</sup></small>) were compared with those treated with a chromatographic separation using a crown ether resin, and additionally with those treated with microwave digestion followed by chromatographic separation. The procedural blank influence was studied and potential interferences of <small><sup>204</sup></small>Hg on the <small><sup>204</sup></small>Pb signal were corrected. An improved chromatographic separation protocol demonstrates the suitability of Pb separation. Mass bias correction factors (<em>K</em> factors) were determined for each ratio and compared for the three procedures. The respective uncertainty budgets for the first time gave direct quantitative indications of differences and uncertainty contributions of the respective digestion and column separation processes compared to untreated solutions. To derive the impact of the preparation steps alone (digestion, column separation), pure SRM® solutions with Pb (no Pb containing matrix samples) were investigated. For <em>K</em>(<small><sup>204</sup></small>Pb/<small><sup>208</sup></small>Pb) an impact of a sample pretreatment cannot be observed and isotopic fractionation can be mainly deduced from the mass spectrometric measurement. In case of the ratios <small><sup>206</sup></small>Pb/<small><sup>208</sup></small>Pb and <small><sup>207</sup></small>Pb/<small><sup>208</sup></small>Pb, the <em>K</em> factors of the digested and column separated as well as only column separated samples can be distinguished from the non-pretreated samples for <em>k</em> = 1, which suggests a small, but observable impact of the sample history on the <em>K</em> factor although the initial samples were matrix-free.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 6\",\"pages\":\" 2263-2272\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2026-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d6ja00106h?page=search\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d6ja00106h\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d6ja00106h","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

采用MC-ICP-MS法,用溶解于0.15 mol kg−1 HNO3中的NIST SRM 981样品分别测定了204Pb/208Pb、206Pb/208Pb和207Pb/208Pb同位素比值的K因子。将主要标准(参比)物质NIST SRM 981 (w(Pb)≈70 ng g−1 ~ 100 ng g−1)的纯溶液与冠醚树脂色谱分离处理过的溶液以及微波消解后色谱分离处理过的溶液进行比较。研究了程序空白影响,修正了204Hg对204Pb信号的潜在干扰。改进的色谱分离方案证明了铅分离的适用性。确定每个比率的质量偏差校正因子(K因子),并对三种方法进行比较。与未经处理的溶液相比,各自的不确定度预算首次给出了各自消化和柱分离过程的差异和不确定度贡献的直接定量指示。为了得出制备步骤(溶出、柱分离)的单独影响,研究了含Pb的纯SRM®溶液(不含Pb的基质样品)。对于K(204Pb/208Pb),样品预处理的影响无法观察到,同位素分馏主要由质谱测量推断。当比例为206Pb/208Pb和207Pb/208Pb时,当K = 1时,消化和柱分离样品以及柱分离样品的K因子与未预处理样品的K因子可以区分,这表明尽管初始样品无基质,但样品历史对K因子的影响很小,但可以观察到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Impact of sample preparation history on isotopic fractionation: isotope ratios of lead SRM 981

Impact of sample preparation history on isotopic fractionation: isotope ratios of lead SRM 981

Several batches of NIST SRM 981 dissolved in 0.15 mol kg−1 HNO3 were used for the determination of K factors of isotope ratios 204Pb/208Pb, 206Pb/208Pb, and 207Pb/208Pb applying MC-ICP-MS. Pure solutions of the primary standard (reference) material NIST SRM 981 (w(Pb) ≈ 70 ng g−1 to 100 ng g−1) were compared with those treated with a chromatographic separation using a crown ether resin, and additionally with those treated with microwave digestion followed by chromatographic separation. The procedural blank influence was studied and potential interferences of 204Hg on the 204Pb signal were corrected. An improved chromatographic separation protocol demonstrates the suitability of Pb separation. Mass bias correction factors (K factors) were determined for each ratio and compared for the three procedures. The respective uncertainty budgets for the first time gave direct quantitative indications of differences and uncertainty contributions of the respective digestion and column separation processes compared to untreated solutions. To derive the impact of the preparation steps alone (digestion, column separation), pure SRM® solutions with Pb (no Pb containing matrix samples) were investigated. For K(204Pb/208Pb) an impact of a sample pretreatment cannot be observed and isotopic fractionation can be mainly deduced from the mass spectrometric measurement. In case of the ratios 206Pb/208Pb and 207Pb/208Pb, the K factors of the digested and column separated as well as only column separated samples can be distinguished from the non-pretreated samples for k = 1, which suggests a small, but observable impact of the sample history on the K factor although the initial samples were matrix-free.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书