一种检测草甘膦的便携式荧光计。

IF 5.6 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Nathanael B Smith, Adrian S Rizk, Owen K Rizk, Shahir S Rizk
{"title":"一种检测草甘膦的便携式荧光计。","authors":"Nathanael B Smith, Adrian S Rizk, Owen K Rizk, Shahir S Rizk","doi":"10.3390/bios16040225","DOIUrl":null,"url":null,"abstract":"<p><p>Glyphosate is the most widely used herbicide worldwide, but many current detection methods rely on lab-based chromatography, requiring costly equipment and expert users. Here, we describe a low-cost, field-deployable fluorescence biosensing platform for glyphosate detection in water and soil. An engineered variant of the <i>Escherichia coli</i> periplasmic binding protein PhnD was optimized through strategic fluorophore placement to produce a robust fluorescence signal increase upon glyphosate binding. The biosensor was integrated into a self-contained, 3D-printed device that functions as a miniature fluorometer, providing a simple yes-or-no output for non-expert users while retaining access to raw fluorescence data. The device exhibits nanomolar fluorescence sensitivity with results comparable to a benchtop fluorometer. Using this platform, glyphosate was reliably detected in buffered solutions, commercial herbicides, tap water, and soil extracts. To mitigate false positives arising from phosphate interference, we developed a dual-sensor strategy incorporating an independent phosphate biosensor and a second-generation device capable of multi-wavelength fluorescence detection. Together, these results demonstrate an affordable and versatile biosensing platform with strong potential for field-based environmental monitoring.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"16 4","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2026-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13115202/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Portable Fluorometer for the Detection of Glyphosate.\",\"authors\":\"Nathanael B Smith, Adrian S Rizk, Owen K Rizk, Shahir S Rizk\",\"doi\":\"10.3390/bios16040225\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Glyphosate is the most widely used herbicide worldwide, but many current detection methods rely on lab-based chromatography, requiring costly equipment and expert users. Here, we describe a low-cost, field-deployable fluorescence biosensing platform for glyphosate detection in water and soil. An engineered variant of the <i>Escherichia coli</i> periplasmic binding protein PhnD was optimized through strategic fluorophore placement to produce a robust fluorescence signal increase upon glyphosate binding. The biosensor was integrated into a self-contained, 3D-printed device that functions as a miniature fluorometer, providing a simple yes-or-no output for non-expert users while retaining access to raw fluorescence data. The device exhibits nanomolar fluorescence sensitivity with results comparable to a benchtop fluorometer. Using this platform, glyphosate was reliably detected in buffered solutions, commercial herbicides, tap water, and soil extracts. To mitigate false positives arising from phosphate interference, we developed a dual-sensor strategy incorporating an independent phosphate biosensor and a second-generation device capable of multi-wavelength fluorescence detection. Together, these results demonstrate an affordable and versatile biosensing platform with strong potential for field-based environmental monitoring.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"16 4\",\"pages\":\"\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2026-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13115202/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios16040225\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios16040225","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

草甘膦是世界上使用最广泛的除草剂,但目前许多检测方法依赖于基于实验室的色谱法,需要昂贵的设备和专家用户。在这里,我们描述了一种低成本,可现场部署的荧光生物传感平台,用于检测水和土壤中的草甘膦。通过战略性地放置荧光团,优化了大肠杆菌周质结合蛋白PhnD的工程变体,使其在与草甘膦结合时产生强大的荧光信号增加。该生物传感器集成到一个独立的3d打印设备中,作为一个微型荧光计,为非专业用户提供简单的是或否输出,同时保留对原始荧光数据的访问权限。该装置具有纳米摩尔荧光灵敏度,其结果可与台式荧光计相媲美。使用该平台,可以在缓冲溶液、商业除草剂、自来水和土壤提取物中可靠地检测草甘膦。为了减轻磷酸盐干扰引起的假阳性,我们开发了一种双传感器策略,包括一个独立的磷酸盐生物传感器和一个能够多波长荧光检测的第二代设备。总之,这些结果展示了一种经济实惠且多功能的生物传感平台,具有基于现场环境监测的强大潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Portable Fluorometer for the Detection of Glyphosate.

Glyphosate is the most widely used herbicide worldwide, but many current detection methods rely on lab-based chromatography, requiring costly equipment and expert users. Here, we describe a low-cost, field-deployable fluorescence biosensing platform for glyphosate detection in water and soil. An engineered variant of the Escherichia coli periplasmic binding protein PhnD was optimized through strategic fluorophore placement to produce a robust fluorescence signal increase upon glyphosate binding. The biosensor was integrated into a self-contained, 3D-printed device that functions as a miniature fluorometer, providing a simple yes-or-no output for non-expert users while retaining access to raw fluorescence data. The device exhibits nanomolar fluorescence sensitivity with results comparable to a benchtop fluorometer. Using this platform, glyphosate was reliably detected in buffered solutions, commercial herbicides, tap water, and soil extracts. To mitigate false positives arising from phosphate interference, we developed a dual-sensor strategy incorporating an independent phosphate biosensor and a second-generation device capable of multi-wavelength fluorescence detection. Together, these results demonstrate an affordable and versatile biosensing platform with strong potential for field-based environmental monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书