直流辉光放电中钆同位素的Lamb浸饱和腔衰荡光谱

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Ryohei Terabayashi, Yuko Nojiri and Shuichi Hasegawa
{"title":"直流辉光放电中钆同位素的Lamb浸饱和腔衰荡光谱","authors":"Ryohei Terabayashi, Yuko Nojiri and Shuichi Hasegawa","doi":"10.1039/D5JA00476D","DOIUrl":null,"url":null,"abstract":"<p >We demonstrate a cavity ring-down spectroscopy (CRDS) system using a direct-current (DC) hollow-cathode glow discharge plasma as an atomic source for isotope-resolved spectroscopy of gadolinium (Gd). This DC glow discharge CRDS provides a compact and simple alternative to conventional inductively coupled plasma (ICP)-based CRDS, while maintaining sufficient stability for high-sensitivity measurements. Saturation effects, more pronounced in atomic than molecular CRDS due to large absorption cross sections, were captured using a saturation model applied to ring-down transients. Saturated CRDS enabled clear observation of Doppler-free lamb dips in Gd spectra, highlighting its capability to resolve narrow spectral features. Combined analysis of Doppler-broadened absorption and lamb dip components allowed estimation of isotopic ratios for the even Gd isotopes, consistent with natural abundances, except for <small><sup>155</sup></small>Gd and <small><sup>157</sup></small>Gd. These results demonstrate the feasibility of applying saturated CRDS to precise isotope ratio measurements of rare-earth elements, and suggest the potential applicability of the technique to other metal atoms, including uranium, plutonium, and other transuranic elements.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 1375-1385"},"PeriodicalIF":3.3000,"publicationDate":"2026-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d5ja00476d?page=search","citationCount":"0","resultStr":"{\"title\":\"Lamb dip saturated cavity ring-down spectroscopy of gadolinium isotopes in a DC glow discharge\",\"authors\":\"Ryohei Terabayashi, Yuko Nojiri and Shuichi Hasegawa\",\"doi\":\"10.1039/D5JA00476D\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >We demonstrate a cavity ring-down spectroscopy (CRDS) system using a direct-current (DC) hollow-cathode glow discharge plasma as an atomic source for isotope-resolved spectroscopy of gadolinium (Gd). This DC glow discharge CRDS provides a compact and simple alternative to conventional inductively coupled plasma (ICP)-based CRDS, while maintaining sufficient stability for high-sensitivity measurements. Saturation effects, more pronounced in atomic than molecular CRDS due to large absorption cross sections, were captured using a saturation model applied to ring-down transients. Saturated CRDS enabled clear observation of Doppler-free lamb dips in Gd spectra, highlighting its capability to resolve narrow spectral features. Combined analysis of Doppler-broadened absorption and lamb dip components allowed estimation of isotopic ratios for the even Gd isotopes, consistent with natural abundances, except for <small><sup>155</sup></small>Gd and <small><sup>157</sup></small>Gd. These results demonstrate the feasibility of applying saturated CRDS to precise isotope ratio measurements of rare-earth elements, and suggest the potential applicability of the technique to other metal atoms, including uranium, plutonium, and other transuranic elements.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 4\",\"pages\":\" 1375-1385\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2026-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d5ja00476d?page=search\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d5ja00476d\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d5ja00476d","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们展示了一个使用直流(DC)空心阴极辉光放电等离子体作为原子源的腔衰荡光谱(CRDS)系统,用于钆(Gd)的同位素分辨光谱。这种直流辉光放电CRDS提供了一种紧凑和简单的替代传统的电感耦合等离子体(ICP) CRDS,同时保持足够的稳定性,用于高灵敏度测量。饱和效应在原子CRDS中比在分子CRDS中更为明显,这是由于吸收截面较大,因此采用了用于衰荡瞬态的饱和模型。饱和CRDS能够清晰地观测到Gd光谱中的无多普勒lamb dip,突出了其解决窄光谱特征的能力。结合多普勒-加宽吸收和lamb倾角组分的分析,可以估计出除155Gd和157Gd外的均匀Gd同位素的同位素比值,与自然丰度一致。这些结果证明了将饱和CRDS应用于稀土元素同位素比精确测量的可行性,并表明该技术可能适用于其他金属原子,包括铀、钚和其他超铀元素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Lamb dip saturated cavity ring-down spectroscopy of gadolinium isotopes in a DC glow discharge

Lamb dip saturated cavity ring-down spectroscopy of gadolinium isotopes in a DC glow discharge

We demonstrate a cavity ring-down spectroscopy (CRDS) system using a direct-current (DC) hollow-cathode glow discharge plasma as an atomic source for isotope-resolved spectroscopy of gadolinium (Gd). This DC glow discharge CRDS provides a compact and simple alternative to conventional inductively coupled plasma (ICP)-based CRDS, while maintaining sufficient stability for high-sensitivity measurements. Saturation effects, more pronounced in atomic than molecular CRDS due to large absorption cross sections, were captured using a saturation model applied to ring-down transients. Saturated CRDS enabled clear observation of Doppler-free lamb dips in Gd spectra, highlighting its capability to resolve narrow spectral features. Combined analysis of Doppler-broadened absorption and lamb dip components allowed estimation of isotopic ratios for the even Gd isotopes, consistent with natural abundances, except for 155Gd and 157Gd. These results demonstrate the feasibility of applying saturated CRDS to precise isotope ratio measurements of rare-earth elements, and suggest the potential applicability of the technique to other metal atoms, including uranium, plutonium, and other transuranic elements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书