光电探测器阵列的数据排序方式

IF 1.5 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION
R. Li , D. Verney , C. Delafosse , M.N. Harakeh , A. Maj , F. Didierjean , L. Al Ayoubi , H. Al Falou , P. Bednarczyk , G. Benzoni , F. Le Blanc , V. Bozkurt , M. Ciemała , F.C.L. Crespi , I. Deloncle , C. Gaulard , A. Gottardo , V. Guadilla , J. Guillot , K. Hadyńska-Klęk , G. Tocabens
{"title":"光电探测器阵列的数据排序方式","authors":"R. Li ,&nbsp;D. Verney ,&nbsp;C. Delafosse ,&nbsp;M.N. Harakeh ,&nbsp;A. Maj ,&nbsp;F. Didierjean ,&nbsp;L. Al Ayoubi ,&nbsp;H. Al Falou ,&nbsp;P. Bednarczyk ,&nbsp;G. Benzoni ,&nbsp;F. Le Blanc ,&nbsp;V. Bozkurt ,&nbsp;M. Ciemała ,&nbsp;F.C.L. Crespi ,&nbsp;I. Deloncle ,&nbsp;C. Gaulard ,&nbsp;A. Gottardo ,&nbsp;V. Guadilla ,&nbsp;J. Guillot ,&nbsp;K. Hadyńska-Klęk ,&nbsp;G. Tocabens","doi":"10.1016/j.nima.2026.171337","DOIUrl":null,"url":null,"abstract":"<div><div>The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4<span><math><mo>−</mo></math></span>10 MeV) <span><math><mi>γ</mi></math></span> rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the <span><math><mi>β</mi></math></span>-decay experiment of <span><math><msup><mrow></mrow><mrow><mn>80</mn><mi>g</mi><mo>+</mo><mi>m</mi></mrow></msup></math></span>Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2”<span><math><mo>×</mo></math></span>2”<span><math><mo>×</mo></math></span>2” LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1086 ","pages":"Article 171337"},"PeriodicalIF":1.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Data sorting modes of phoswich detector array\",\"authors\":\"R. Li ,&nbsp;D. Verney ,&nbsp;C. Delafosse ,&nbsp;M.N. Harakeh ,&nbsp;A. Maj ,&nbsp;F. Didierjean ,&nbsp;L. Al Ayoubi ,&nbsp;H. Al Falou ,&nbsp;P. Bednarczyk ,&nbsp;G. Benzoni ,&nbsp;F. Le Blanc ,&nbsp;V. Bozkurt ,&nbsp;M. Ciemała ,&nbsp;F.C.L. Crespi ,&nbsp;I. Deloncle ,&nbsp;C. Gaulard ,&nbsp;A. Gottardo ,&nbsp;V. Guadilla ,&nbsp;J. Guillot ,&nbsp;K. Hadyńska-Klęk ,&nbsp;G. Tocabens\",\"doi\":\"10.1016/j.nima.2026.171337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4<span><math><mo>−</mo></math></span>10 MeV) <span><math><mi>γ</mi></math></span> rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the <span><math><mi>β</mi></math></span>-decay experiment of <span><math><msup><mrow></mrow><mrow><mn>80</mn><mi>g</mi><mo>+</mo><mi>m</mi></mrow></msup></math></span>Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2”<span><math><mo>×</mo></math></span>2”<span><math><mo>×</mo></math></span>2” LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1086 \",\"pages\":\"Article 171337\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2026-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S016890022600063X\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/2/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S016890022600063X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

研究了用于探测高能(4−10 MeV) γ射线的光电探测器阵列PARIS的不同数据排序模式。研究了不同模式下的时间分辨率、能量分辨率和探测效率等特性。本研究表明,当用于衰减光谱时,PARIS具有抑制逃逸和堆积事件的能力。值得注意的是,本工作中提出的方法专门针对由27个光电探测器组成的三个PARIS簇进行的80g+mGa β衰变实验,而不是对PARIS阵列或其光束内光谱整体性能的一般报告。与2 ‘ ’ ×2 ‘ ’ ×2 ' ' LaBr3(Ce)探测器(Ciemała et al., 2009)相比,即使在单个模式下,PARIS也能通过外体积NaI(Tl)晶体的否决函数显著抑制单峰和双逸出峰,并降低背景。与在LaBr3(Ce)和NaI(Tl)中添加能量以提高全能峰检测效率的常见方法相反,使用NaI(Tl)作为否决屏蔽为光谱纯度至关重要的应用提供了优越的权衡。在每个光子簇内或所有光子簇之间进行加回分析可以提高全能量峰效率,并进一步抑制逃逸峰和背景。应用多重性条件提供了进一步的抑制,但同时降低了全能量峰的统计量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Data sorting modes of phoswich detector array
The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4−10 MeV) γ rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the β-decay experiment of 80g+mGa conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2”×2”×2” LaBr3(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr3(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书