{"title":"早产儿眼压的meta分析。","authors":"Kalina Trifonova, Kiril Slaveykov, Hristo Mumdzhiev","doi":"10.20471/acc.2025.64.02.22","DOIUrl":null,"url":null,"abstract":"<p><p>The intraocular pressure (IOP) ranges of premature newborns are not the same as those in full-term newborns and adult population. The exact ranges and causes, however, differ depending on the measurement techniques used and analysis. Our study aimed to summarize and analyze available information in the up-to-date literature concerning IOP values in premature newborns. We performed a systematic literature review with meta-analysis. Our research showed the mean IOP in premature newborns to range from 10 to 29 mmHg according to different authors, and its mean values were higher in premature compared to full-term newborns. The most commonly analyzed factor that probably affected IOP measurement was central corneal thickness. Longitudinal studies showed that IOP and central corneal thickness declined with maturation of the newborn and both factors were probably correlated. Additional studies with larger sample sizes and better differentiated sample groups need to be performed.</p>","PeriodicalId":7072,"journal":{"name":"Acta clinica Croatica","volume":"64 2","pages":"380-387"},"PeriodicalIF":0.5000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12863291/pdf/","citationCount":"0","resultStr":"{\"title\":\"INTRAOCULAR PRESSURE OF PREMATURE NEWBORNS - A SYSTEMATIC REVIEW WITH META-ANALYSIS.\",\"authors\":\"Kalina Trifonova, Kiril Slaveykov, Hristo Mumdzhiev\",\"doi\":\"10.20471/acc.2025.64.02.22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The intraocular pressure (IOP) ranges of premature newborns are not the same as those in full-term newborns and adult population. The exact ranges and causes, however, differ depending on the measurement techniques used and analysis. Our study aimed to summarize and analyze available information in the up-to-date literature concerning IOP values in premature newborns. We performed a systematic literature review with meta-analysis. Our research showed the mean IOP in premature newborns to range from 10 to 29 mmHg according to different authors, and its mean values were higher in premature compared to full-term newborns. The most commonly analyzed factor that probably affected IOP measurement was central corneal thickness. Longitudinal studies showed that IOP and central corneal thickness declined with maturation of the newborn and both factors were probably correlated. Additional studies with larger sample sizes and better differentiated sample groups need to be performed.</p>\",\"PeriodicalId\":7072,\"journal\":{\"name\":\"Acta clinica Croatica\",\"volume\":\"64 2\",\"pages\":\"380-387\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2025-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12863291/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta clinica Croatica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.20471/acc.2025.64.02.22\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta clinica Croatica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20471/acc.2025.64.02.22","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
INTRAOCULAR PRESSURE OF PREMATURE NEWBORNS - A SYSTEMATIC REVIEW WITH META-ANALYSIS.
The intraocular pressure (IOP) ranges of premature newborns are not the same as those in full-term newborns and adult population. The exact ranges and causes, however, differ depending on the measurement techniques used and analysis. Our study aimed to summarize and analyze available information in the up-to-date literature concerning IOP values in premature newborns. We performed a systematic literature review with meta-analysis. Our research showed the mean IOP in premature newborns to range from 10 to 29 mmHg according to different authors, and its mean values were higher in premature compared to full-term newborns. The most commonly analyzed factor that probably affected IOP measurement was central corneal thickness. Longitudinal studies showed that IOP and central corneal thickness declined with maturation of the newborn and both factors were probably correlated. Additional studies with larger sample sizes and better differentiated sample groups need to be performed.
期刊介绍:
Acta Clinica Croatica is a peer reviewed general medical journal that publishes original articles that advance and improve medical science and practice and that serve the purpose of transfer of original and valuable information to journal readers. Acta Clinica Croatica is published in English four times a year.