钢板与髓内螺钉固定治疗关节外掌骨基部骨折的生物力学比较

Q3 Medicine
Journal of Hand Surgery Global Online Pub Date : 2026-03-01 Epub Date: 2025-12-15 DOI:10.1016/j.jhsg.2025.100897
Majd Mzeihem MD , Dmitriy Peresada MD , Yeseop Park PhD , Jiries A. Fakhouri BS , Danil Rybalko MD , Mark H. Gonzalez MD, PhD , Farid Amirouche PhD
{"title":"钢板与髓内螺钉固定治疗关节外掌骨基部骨折的生物力学比较","authors":"Majd Mzeihem MD ,&nbsp;Dmitriy Peresada MD ,&nbsp;Yeseop Park PhD ,&nbsp;Jiries A. Fakhouri BS ,&nbsp;Danil Rybalko MD ,&nbsp;Mark H. Gonzalez MD, PhD ,&nbsp;Farid Amirouche PhD","doi":"10.1016/j.jhsg.2025.100897","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>Intramedullary (IM) screws are commonly used for metacarpal shaft and neck fractures, but their application in extra-articular metacarpal base fractures has not been thoroughly evaluated. This study aims to compare the biomechanical performance (load to failure) of IM screw fixation versus dorsal plate fixation for extra-articular fractures at the base of the metacarpal.</div></div><div><h3>Methods</h3><div>Twenty-four cadaveric metacarpals from 12 upper extremities were prepared and randomized to receive either IM screw fixation or dorsal plate fixation following a standardized transverse fracture near the base. All specimens were potted and tested using cantilever bending in a materials testing system. The primary outcome was ultimate load to failure; stiffness was evaluated as a secondary measure.</div></div><div><h3>Results</h3><div>Dorsal plate fixation demonstrated greater load to failure compared to IM screw fixation when all specimens were analyzed collectively. Subgroup analysis indicated this difference was more pronounced in the thumb metacarpals. In contrast, IM screw constructs consistently exhibited greater stiffness across all specimens, including both thumb and small finger metacarpals.</div></div><div><h3>Conclusions</h3><div>Dorsal plating offered greater resistance to fracture displacement, while IM screw fixation provided superior construct stiffness. Both fixation methods surpassed expected physiologic loading during hand use, indicating that either approach may be biomechanically acceptable depending on the clinical context.</div></div><div><h3>Clinical relevance</h3><div>The IM screws may serve as a biomechanically viable alternative to dorsal plates for extra-articular metacarpal base fractures. These findings may help guide surgical decision-making regarding fixation selection and promote individualized treatment strategies.</div></div>","PeriodicalId":36920,"journal":{"name":"Journal of Hand Surgery Global Online","volume":"8 2","pages":"Article 100897"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical Comparison of Plate Versus Intramedullary Screw Fixation for Extra-Articular Metacarpal Base Fractures\",\"authors\":\"Majd Mzeihem MD ,&nbsp;Dmitriy Peresada MD ,&nbsp;Yeseop Park PhD ,&nbsp;Jiries A. Fakhouri BS ,&nbsp;Danil Rybalko MD ,&nbsp;Mark H. Gonzalez MD, PhD ,&nbsp;Farid Amirouche PhD\",\"doi\":\"10.1016/j.jhsg.2025.100897\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><div>Intramedullary (IM) screws are commonly used for metacarpal shaft and neck fractures, but their application in extra-articular metacarpal base fractures has not been thoroughly evaluated. This study aims to compare the biomechanical performance (load to failure) of IM screw fixation versus dorsal plate fixation for extra-articular fractures at the base of the metacarpal.</div></div><div><h3>Methods</h3><div>Twenty-four cadaveric metacarpals from 12 upper extremities were prepared and randomized to receive either IM screw fixation or dorsal plate fixation following a standardized transverse fracture near the base. All specimens were potted and tested using cantilever bending in a materials testing system. The primary outcome was ultimate load to failure; stiffness was evaluated as a secondary measure.</div></div><div><h3>Results</h3><div>Dorsal plate fixation demonstrated greater load to failure compared to IM screw fixation when all specimens were analyzed collectively. Subgroup analysis indicated this difference was more pronounced in the thumb metacarpals. In contrast, IM screw constructs consistently exhibited greater stiffness across all specimens, including both thumb and small finger metacarpals.</div></div><div><h3>Conclusions</h3><div>Dorsal plating offered greater resistance to fracture displacement, while IM screw fixation provided superior construct stiffness. Both fixation methods surpassed expected physiologic loading during hand use, indicating that either approach may be biomechanically acceptable depending on the clinical context.</div></div><div><h3>Clinical relevance</h3><div>The IM screws may serve as a biomechanically viable alternative to dorsal plates for extra-articular metacarpal base fractures. These findings may help guide surgical decision-making regarding fixation selection and promote individualized treatment strategies.</div></div>\",\"PeriodicalId\":36920,\"journal\":{\"name\":\"Journal of Hand Surgery Global Online\",\"volume\":\"8 2\",\"pages\":\"Article 100897\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2026-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hand Surgery Global Online\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2589514125002178\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/12/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery Global Online","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589514125002178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的髓内螺钉常用于掌骨干部和颈部骨折,但其在掌骨关节外骨折中的应用尚未得到充分评价。本研究旨在比较IM螺钉固定与背侧钢板固定治疗掌骨基部关节外骨折的生物力学性能(负荷至失效)。方法选取12只上肢的24具尸体掌骨,随机接受近基底标准化横向骨折后的IM螺钉固定或背侧钢板固定。所有的试样都在材料测试系统中进行了盆栽和悬臂弯曲测试。主要结局是最终负荷失败;刚度作为次要指标进行评估。结果对所有标本进行综合分析时,与内钉固定相比,背侧钢板固定显示出更大的失效负荷。亚组分析表明,这种差异在拇指掌骨中更为明显。相比之下,IM螺钉结构在所有标本中均表现出更大的刚度,包括拇指和小指掌骨。结论背侧钢板具有更好的抗骨折移位能力,而内固定螺钉具有更好的结构刚度。两种固定方法都超过了手部使用时预期的生理负荷,这表明根据临床情况,两种方法在生物力学上都是可接受的。临床意义IM螺钉可作为一种生物力学上可行的替代背钢板治疗关节外掌骨基部骨折。这些发现可能有助于指导手术决策关于固定选择和促进个体化治疗策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biomechanical Comparison of Plate Versus Intramedullary Screw Fixation for Extra-Articular Metacarpal Base Fractures

Purpose

Intramedullary (IM) screws are commonly used for metacarpal shaft and neck fractures, but their application in extra-articular metacarpal base fractures has not been thoroughly evaluated. This study aims to compare the biomechanical performance (load to failure) of IM screw fixation versus dorsal plate fixation for extra-articular fractures at the base of the metacarpal.

Methods

Twenty-four cadaveric metacarpals from 12 upper extremities were prepared and randomized to receive either IM screw fixation or dorsal plate fixation following a standardized transverse fracture near the base. All specimens were potted and tested using cantilever bending in a materials testing system. The primary outcome was ultimate load to failure; stiffness was evaluated as a secondary measure.

Results

Dorsal plate fixation demonstrated greater load to failure compared to IM screw fixation when all specimens were analyzed collectively. Subgroup analysis indicated this difference was more pronounced in the thumb metacarpals. In contrast, IM screw constructs consistently exhibited greater stiffness across all specimens, including both thumb and small finger metacarpals.

Conclusions

Dorsal plating offered greater resistance to fracture displacement, while IM screw fixation provided superior construct stiffness. Both fixation methods surpassed expected physiologic loading during hand use, indicating that either approach may be biomechanically acceptable depending on the clinical context.

Clinical relevance

The IM screws may serve as a biomechanically viable alternative to dorsal plates for extra-articular metacarpal base fractures. These findings may help guide surgical decision-making regarding fixation selection and promote individualized treatment strategies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
111
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书