Pablo Martinez-Reviriego, Paz Alonso-Arias, Nuria Catalan-Lasheras, Alexej Grudiev, Pedro Morales Sanchez, Ping Wang
{"title":"用于CLIC x波段结构的HOM SiC负载:设计和测量","authors":"Pablo Martinez-Reviriego, Paz Alonso-Arias, Nuria Catalan-Lasheras, Alexej Grudiev, Pedro Morales Sanchez, Ping Wang","doi":"10.1016/j.nima.2025.171076","DOIUrl":null,"url":null,"abstract":"<div><div>The Compact Linear Collider (CLIC) main linac employs a waveguide-damped structure as its baseline design. To ensure beam dynamic stability, the transverse wakefield must be less than 3.4 V/pC/m/mm in 0.5 ns, corresponding with the position of the second bunch. This study focuses on optimizing high-order-mode (HOM) damping loads through new material measurements, achieving enhanced suppression of long-range transverse wakefields. The new damping load is 20% more compact than those in the previous CLIC structure design.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1082 ","pages":"Article 171076"},"PeriodicalIF":1.4000,"publicationDate":"2025-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"HOM SiC loads for CLIC X-band structures: Design and measurements\",\"authors\":\"Pablo Martinez-Reviriego, Paz Alonso-Arias, Nuria Catalan-Lasheras, Alexej Grudiev, Pedro Morales Sanchez, Ping Wang\",\"doi\":\"10.1016/j.nima.2025.171076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The Compact Linear Collider (CLIC) main linac employs a waveguide-damped structure as its baseline design. To ensure beam dynamic stability, the transverse wakefield must be less than 3.4 V/pC/m/mm in 0.5 ns, corresponding with the position of the second bunch. This study focuses on optimizing high-order-mode (HOM) damping loads through new material measurements, achieving enhanced suppression of long-range transverse wakefields. The new damping load is 20% more compact than those in the previous CLIC structure design.</div></div>\",\"PeriodicalId\":19359,\"journal\":{\"name\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"volume\":\"1082 \",\"pages\":\"Article 171076\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0168900225008782\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900225008782","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
HOM SiC loads for CLIC X-band structures: Design and measurements
The Compact Linear Collider (CLIC) main linac employs a waveguide-damped structure as its baseline design. To ensure beam dynamic stability, the transverse wakefield must be less than 3.4 V/pC/m/mm in 0.5 ns, corresponding with the position of the second bunch. This study focuses on optimizing high-order-mode (HOM) damping loads through new material measurements, achieving enhanced suppression of long-range transverse wakefields. The new damping load is 20% more compact than those in the previous CLIC structure design.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.