“远远超出形状”:三种当代全体内机器人原位新膀胱技术的早期头对头比较尿动力学分析。

IF 3 3区 医学 Q2 SURGERY
Umberto Anceschi, Salvatore Basile, Daniele Amparore, Fabrizio Di Maida, Riccardo Mastroianni, Sabrina De Cillis, Giulia D'Ippolito, Antonio Andrea Grosso, Gabriele Tuderti, Eleonora Rosato, Rocco Simone Flammia, Luca Lambertini, Aldo Brassetti, Francesco Lupo Conte, Enrico Finazzi Agrò, Cristian Fiori, Francesco Porpiglia, Andrea Minervini, Giuseppe Simone
{"title":"“远远超出形状”:三种当代全体内机器人原位新膀胱技术的早期头对头比较尿动力学分析。","authors":"Umberto Anceschi, Salvatore Basile, Daniele Amparore, Fabrizio Di Maida, Riccardo Mastroianni, Sabrina De Cillis, Giulia D'Ippolito, Antonio Andrea Grosso, Gabriele Tuderti, Eleonora Rosato, Rocco Simone Flammia, Luca Lambertini, Aldo Brassetti, Francesco Lupo Conte, Enrico Finazzi Agrò, Cristian Fiori, Francesco Porpiglia, Andrea Minervini, Giuseppe Simone","doi":"10.1007/s11701-025-02821-4","DOIUrl":null,"url":null,"abstract":"<p><p>The expanding use of totally intracorporeal orthotopic neobladder (ICONB) reconstruction after robot-assisted radical cystectomy has fostered multiple configuration variants, yet robust comparative functional data remain limited. This early head-to-head study aimed to assess whether three contemporary ICONB configurations-Padua Ileal Neobladder, Florence Robotic Intracorporeal Neobladder (FloRIN), and a Y-shaped neobladder-deliver comparable urodynamic and continence outcomes despite anatomical nuances. Three prospectively maintained institutional cystectomy databases were merged. Patients who underwent robot-assisted radical cystectomy with ICONB and completed a standardized early multichannel urodynamic assessment were included. Cystometric capacity, compliance, residual peristaltic activity, leak point pressures, and functional continence (daytime and night-time) were compared across configurations. Functional recovery probabilities were estimated using Kaplan-Meier curves and compared with the log-rank test. Non-parametric tests were applied for other comparisons. A total of 142 patients were analyzed (Padua n = 45, FloRIN n = 49, Y-shaped n = 48). Median cystometric capacity was highest in the Padua configuration (346 mL [IQR 272-400]) versus FloRIN (269 mL [242-305]) and Y-shaped (245 mL [200-290]; p < 0.001). Compliance was most favorable in FloRIN (22 mL/cmH₂O [15-27]) compared to Padua (16 [11-41]) and Y-shaped (12 [10-19]; p = 0.029). Residual peristaltic activity and leak point pressures showed minor differences without functional impact. Daytime continence rates were similar (Padua 80%, FloRIN 83%, Y-shaped 79%; p = 0.40); night-time continence followed the same pattern (65%, 70%, 66%; p = 0.30). Kaplan-Meier curves demonstrated overlapping functional recovery trajectories (daytime p = 0.744; night-time p = 0.122). This early head-to-head comparison suggests that when core reconstructive principles are met, contemporary totally intracorporeal neobladder configurations yield distinct urodynamic profiles but comparable functional outcomes. Future efforts should define clear qualitative and temporal standards for urodynamic monitoring to support consistent functional evaluation as robotic cystectomy adoption expands.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"19 1","pages":"689"},"PeriodicalIF":3.0000,"publicationDate":"2025-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"\\\"Far beyond the shape\\\": an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques.\",\"authors\":\"Umberto Anceschi, Salvatore Basile, Daniele Amparore, Fabrizio Di Maida, Riccardo Mastroianni, Sabrina De Cillis, Giulia D'Ippolito, Antonio Andrea Grosso, Gabriele Tuderti, Eleonora Rosato, Rocco Simone Flammia, Luca Lambertini, Aldo Brassetti, Francesco Lupo Conte, Enrico Finazzi Agrò, Cristian Fiori, Francesco Porpiglia, Andrea Minervini, Giuseppe Simone\",\"doi\":\"10.1007/s11701-025-02821-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The expanding use of totally intracorporeal orthotopic neobladder (ICONB) reconstruction after robot-assisted radical cystectomy has fostered multiple configuration variants, yet robust comparative functional data remain limited. This early head-to-head study aimed to assess whether three contemporary ICONB configurations-Padua Ileal Neobladder, Florence Robotic Intracorporeal Neobladder (FloRIN), and a Y-shaped neobladder-deliver comparable urodynamic and continence outcomes despite anatomical nuances. Three prospectively maintained institutional cystectomy databases were merged. Patients who underwent robot-assisted radical cystectomy with ICONB and completed a standardized early multichannel urodynamic assessment were included. Cystometric capacity, compliance, residual peristaltic activity, leak point pressures, and functional continence (daytime and night-time) were compared across configurations. Functional recovery probabilities were estimated using Kaplan-Meier curves and compared with the log-rank test. Non-parametric tests were applied for other comparisons. A total of 142 patients were analyzed (Padua n = 45, FloRIN n = 49, Y-shaped n = 48). Median cystometric capacity was highest in the Padua configuration (346 mL [IQR 272-400]) versus FloRIN (269 mL [242-305]) and Y-shaped (245 mL [200-290]; p < 0.001). Compliance was most favorable in FloRIN (22 mL/cmH₂O [15-27]) compared to Padua (16 [11-41]) and Y-shaped (12 [10-19]; p = 0.029). Residual peristaltic activity and leak point pressures showed minor differences without functional impact. Daytime continence rates were similar (Padua 80%, FloRIN 83%, Y-shaped 79%; p = 0.40); night-time continence followed the same pattern (65%, 70%, 66%; p = 0.30). Kaplan-Meier curves demonstrated overlapping functional recovery trajectories (daytime p = 0.744; night-time p = 0.122). This early head-to-head comparison suggests that when core reconstructive principles are met, contemporary totally intracorporeal neobladder configurations yield distinct urodynamic profiles but comparable functional outcomes. Future efforts should define clear qualitative and temporal standards for urodynamic monitoring to support consistent functional evaluation as robotic cystectomy adoption expands.</p>\",\"PeriodicalId\":47616,\"journal\":{\"name\":\"Journal of Robotic Surgery\",\"volume\":\"19 1\",\"pages\":\"689\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Robotic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11701-025-02821-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-025-02821-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

机器人辅助根治性膀胱切除术后,全体内原位新膀胱(ICONB)重建的广泛应用促进了多种形态变异,但可靠的比较功能数据仍然有限。这项早期的头对头研究旨在评估三种当代ICONB配置-帕多瓦回肠新膀胱,佛罗伦萨机器人体内新膀胱(FloRIN)和y形新膀胱-是否具有相似的尿动力学和尿失禁结果,尽管解剖上存在细微差别。合并三个前瞻性维持的机构膀胱切除术数据库。接受ICONB机器人辅助根治性膀胱切除术并完成标准化早期多通道尿动力学评估的患者纳入研究。比较不同配置的膀胱容量、顺应性、残余蠕动活动、泄漏点压力和功能失禁(白天和夜间)。使用Kaplan-Meier曲线估计功能恢复概率,并与log-rank检验进行比较。其他比较采用非参数检验。共分析142例患者(Padua n = 45, FloRIN n = 49, y型n = 48)。中位膀胱容量在帕多瓦组(346 mL [IQR 272-400])高于FloRIN组(269 mL[242-305])和y型组(245 mL [200-290])
本文章由计算机程序翻译,如有差异,请以英文原文为准。
"Far beyond the shape": an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques.

The expanding use of totally intracorporeal orthotopic neobladder (ICONB) reconstruction after robot-assisted radical cystectomy has fostered multiple configuration variants, yet robust comparative functional data remain limited. This early head-to-head study aimed to assess whether three contemporary ICONB configurations-Padua Ileal Neobladder, Florence Robotic Intracorporeal Neobladder (FloRIN), and a Y-shaped neobladder-deliver comparable urodynamic and continence outcomes despite anatomical nuances. Three prospectively maintained institutional cystectomy databases were merged. Patients who underwent robot-assisted radical cystectomy with ICONB and completed a standardized early multichannel urodynamic assessment were included. Cystometric capacity, compliance, residual peristaltic activity, leak point pressures, and functional continence (daytime and night-time) were compared across configurations. Functional recovery probabilities were estimated using Kaplan-Meier curves and compared with the log-rank test. Non-parametric tests were applied for other comparisons. A total of 142 patients were analyzed (Padua n = 45, FloRIN n = 49, Y-shaped n = 48). Median cystometric capacity was highest in the Padua configuration (346 mL [IQR 272-400]) versus FloRIN (269 mL [242-305]) and Y-shaped (245 mL [200-290]; p < 0.001). Compliance was most favorable in FloRIN (22 mL/cmH₂O [15-27]) compared to Padua (16 [11-41]) and Y-shaped (12 [10-19]; p = 0.029). Residual peristaltic activity and leak point pressures showed minor differences without functional impact. Daytime continence rates were similar (Padua 80%, FloRIN 83%, Y-shaped 79%; p = 0.40); night-time continence followed the same pattern (65%, 70%, 66%; p = 0.30). Kaplan-Meier curves demonstrated overlapping functional recovery trajectories (daytime p = 0.744; night-time p = 0.122). This early head-to-head comparison suggests that when core reconstructive principles are met, contemporary totally intracorporeal neobladder configurations yield distinct urodynamic profiles but comparable functional outcomes. Future efforts should define clear qualitative and temporal standards for urodynamic monitoring to support consistent functional evaluation as robotic cystectomy adoption expands.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.20
自引率
8.70%
发文量
145
期刊介绍: The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信