{"title":"一种新型固相ABO和RhD血型分型试剂盒的评价。","authors":"Yuelong Xu, Rong Wang, Dongmei Ge, Xingyu Huang, Yuanming Yang, Zifan Meng, Haiyan Wang, Ying Li","doi":"10.1111/tme.70032","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Rapid and accurate identification of blood groups is the foundation of emergency blood support. We performed a complete assessment of a new solid-phase kit for ABO forward grouping and RhD grouping (ABD Kit, InTec Products, Xiamen, China) on the analytical performance, which was compared with those of traditional methods.</p><p><strong>Methods: </strong>We analysed 1260 clinical samples using the ABD Kit, including weakly agglutinated samples of A, B and D antigen, and compared the test results with those via Gel card, test tube and slide methods. We also validated the results of typing blood samples containing weak antigens using first-generation gene sequencing.</p><p><strong>Results: </strong>The ABO forward group and RhD group of 1260 samples was determined using ABD Kit, revealing that the inter-batch repeatability rate of the kit was 100%. The results of the kit were compared with those of the gel card method, revealing that the detection accuracy of the kit was also 100%, which was confirmed by comparing the detection of weak antigen samples with the results of first-generation gene sequencing. The accuracy of the test tube agglutination method was 100%. In contrast, the accuracy of the slide agglutination method was low, especially in the detection of weak A blood antigens (agglutination strength 1+), weak B blood antigens (agglutination strength 1+) and weak D blood antigens (agglutination strength 1+ or 2+).</p><p><strong>Conclusions: </strong>The ABD Kit (InTec Products, Xiamen, China) showed high sensitivity, reproducibility and specificity, indicative of excellent analytical performance. It is a reliable, practical and promising solution for rapid and accurate identification of blood types.</p>","PeriodicalId":23306,"journal":{"name":"Transfusion Medicine","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2025-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a new solid-phase ABO and RhD blood grouping kit.\",\"authors\":\"Yuelong Xu, Rong Wang, Dongmei Ge, Xingyu Huang, Yuanming Yang, Zifan Meng, Haiyan Wang, Ying Li\",\"doi\":\"10.1111/tme.70032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Rapid and accurate identification of blood groups is the foundation of emergency blood support. We performed a complete assessment of a new solid-phase kit for ABO forward grouping and RhD grouping (ABD Kit, InTec Products, Xiamen, China) on the analytical performance, which was compared with those of traditional methods.</p><p><strong>Methods: </strong>We analysed 1260 clinical samples using the ABD Kit, including weakly agglutinated samples of A, B and D antigen, and compared the test results with those via Gel card, test tube and slide methods. We also validated the results of typing blood samples containing weak antigens using first-generation gene sequencing.</p><p><strong>Results: </strong>The ABO forward group and RhD group of 1260 samples was determined using ABD Kit, revealing that the inter-batch repeatability rate of the kit was 100%. The results of the kit were compared with those of the gel card method, revealing that the detection accuracy of the kit was also 100%, which was confirmed by comparing the detection of weak antigen samples with the results of first-generation gene sequencing. The accuracy of the test tube agglutination method was 100%. In contrast, the accuracy of the slide agglutination method was low, especially in the detection of weak A blood antigens (agglutination strength 1+), weak B blood antigens (agglutination strength 1+) and weak D blood antigens (agglutination strength 1+ or 2+).</p><p><strong>Conclusions: </strong>The ABD Kit (InTec Products, Xiamen, China) showed high sensitivity, reproducibility and specificity, indicative of excellent analytical performance. It is a reliable, practical and promising solution for rapid and accurate identification of blood types.</p>\",\"PeriodicalId\":23306,\"journal\":{\"name\":\"Transfusion Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transfusion Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/tme.70032\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/tme.70032","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Evaluation of a new solid-phase ABO and RhD blood grouping kit.
Objectives: Rapid and accurate identification of blood groups is the foundation of emergency blood support. We performed a complete assessment of a new solid-phase kit for ABO forward grouping and RhD grouping (ABD Kit, InTec Products, Xiamen, China) on the analytical performance, which was compared with those of traditional methods.
Methods: We analysed 1260 clinical samples using the ABD Kit, including weakly agglutinated samples of A, B and D antigen, and compared the test results with those via Gel card, test tube and slide methods. We also validated the results of typing blood samples containing weak antigens using first-generation gene sequencing.
Results: The ABO forward group and RhD group of 1260 samples was determined using ABD Kit, revealing that the inter-batch repeatability rate of the kit was 100%. The results of the kit were compared with those of the gel card method, revealing that the detection accuracy of the kit was also 100%, which was confirmed by comparing the detection of weak antigen samples with the results of first-generation gene sequencing. The accuracy of the test tube agglutination method was 100%. In contrast, the accuracy of the slide agglutination method was low, especially in the detection of weak A blood antigens (agglutination strength 1+), weak B blood antigens (agglutination strength 1+) and weak D blood antigens (agglutination strength 1+ or 2+).
Conclusions: The ABD Kit (InTec Products, Xiamen, China) showed high sensitivity, reproducibility and specificity, indicative of excellent analytical performance. It is a reliable, practical and promising solution for rapid and accurate identification of blood types.
期刊介绍:
Transfusion Medicine publishes articles on transfusion medicine in its widest context, including blood transfusion practice (blood procurement, pharmaceutical, clinical, scientific, computing and documentary aspects), immunohaematology, immunogenetics, histocompatibility, medico-legal applications, and related molecular biology and biotechnology.
In addition to original articles, which may include brief communications and case reports, the journal contains a regular educational section (based on invited reviews and state-of-the-art reports), technical section (including quality assurance and current practice guidelines), leading articles, letters to the editor, occasional historical articles and signed book reviews. Some lectures from Society meetings that are likely to be of general interest to readers of the Journal may be published at the discretion of the Editor and subject to the availability of space in the Journal.