{"title":"基于捕集器的可回收液滴微流控装置用于浆液中污染物的分析。","authors":"Sung Wook Choi,Dong Hyeong Kim,Soo-Hwan Jeong,Ju Hyeon Kim,Jae Bem You","doi":"10.1021/acssensors.5c01878","DOIUrl":null,"url":null,"abstract":"Liquid-liquid microextraction (LLME) is a cost-effective sample pretreatment method for the analysis of trace analytes in various samples, such as water, blood, urine, and others. In LLME, the high surface area-to-volume ratio of the extractant enables fast accumulation of analytes from the sample into the extractant. The analyte-loaded extractant can easily be analyzed by using common analytical instruments such as liquid or gas chromatography, mass spectrometry, and others. However, a critical drawback of LLME is that when the sample contains solid fragments, microextraction must be preceded by a removal step, which can result in the loss of the analyte and compromise the detection. In this work, we demonstrate microextraction of analytes from a slurry solution without the need for an additional pretreatment step using a trap-based microfluidic device with a retrievable extractant. The extractant, 1-Octanol, is loaded into a microchamber that is in contact with a microchannel that continuously introduces the sample solution. As the solution flows in the microchannel, the intimate contact of the solution with the extractant enables the fast extraction of analytes. Using Nile red (NR) as a model analyte, we demonstrate the influence of the analyte concentration and the flow rate of the sample solution on the extraction. As a proof-of-concept, we show successful extraction of trace amounts of perfluorooctanoic acid (PFOA) from water. More importantly, the device enables one-step extraction of target analytes, e.g., carbamazepine (CBZ), from a concentrated sand suspension. The extracted CBZ is easily analyzed by using high-performance liquid chromatography, eliminating the need to remove the solid content prior to extraction. The approach shown in this work can potentially be applied to various fields, such as drug detection, environmental pollution monitoring, or food safety for pesticide residue analysis.","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":"73 1","pages":""},"PeriodicalIF":9.1000,"publicationDate":"2025-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Trap-Based Microfluidic Device with Retrivable Droplet for the Analysis of Pollutants from Slurry Solutions.\",\"authors\":\"Sung Wook Choi,Dong Hyeong Kim,Soo-Hwan Jeong,Ju Hyeon Kim,Jae Bem You\",\"doi\":\"10.1021/acssensors.5c01878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Liquid-liquid microextraction (LLME) is a cost-effective sample pretreatment method for the analysis of trace analytes in various samples, such as water, blood, urine, and others. In LLME, the high surface area-to-volume ratio of the extractant enables fast accumulation of analytes from the sample into the extractant. The analyte-loaded extractant can easily be analyzed by using common analytical instruments such as liquid or gas chromatography, mass spectrometry, and others. However, a critical drawback of LLME is that when the sample contains solid fragments, microextraction must be preceded by a removal step, which can result in the loss of the analyte and compromise the detection. In this work, we demonstrate microextraction of analytes from a slurry solution without the need for an additional pretreatment step using a trap-based microfluidic device with a retrievable extractant. The extractant, 1-Octanol, is loaded into a microchamber that is in contact with a microchannel that continuously introduces the sample solution. As the solution flows in the microchannel, the intimate contact of the solution with the extractant enables the fast extraction of analytes. Using Nile red (NR) as a model analyte, we demonstrate the influence of the analyte concentration and the flow rate of the sample solution on the extraction. As a proof-of-concept, we show successful extraction of trace amounts of perfluorooctanoic acid (PFOA) from water. More importantly, the device enables one-step extraction of target analytes, e.g., carbamazepine (CBZ), from a concentrated sand suspension. The extracted CBZ is easily analyzed by using high-performance liquid chromatography, eliminating the need to remove the solid content prior to extraction. The approach shown in this work can potentially be applied to various fields, such as drug detection, environmental pollution monitoring, or food safety for pesticide residue analysis.\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":\"73 1\",\"pages\":\"\"},\"PeriodicalIF\":9.1000,\"publicationDate\":\"2025-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acssensors.5c01878\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.5c01878","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

液液微萃取(LLME)是一种具有成本效益的样品前处理方法,用于分析各种样品中的痕量分析物,如水、血液、尿液等。在LLME中,萃取剂的高表面积体积比使分析物从样品中快速积累到萃取剂中。负载分析物的萃取剂可以很容易地通过使用常见的分析仪器,如液体或气相色谱,质谱分析等进行分析。然而,LLME的一个关键缺点是,当样品含有固体碎片时,微萃取之前必须经过去除步骤,这可能导致分析物的损失并影响检测。在这项工作中,我们演示了从浆液溶液中微萃取分析物,而不需要使用带有可回收萃取剂的基于捕集器的微流体装置进行额外的预处理步骤。萃取剂1-辛醇被装入微室,微室与微通道接触,微通道不断引入样品溶液。当溶液在微通道中流动时,溶液与萃取剂的密切接触使分析物能够快速提取。以尼罗红(NR)为模型分析物,研究了分析物浓度和样品溶液流速对萃取的影响。作为概念验证,我们展示了从水中成功提取微量全氟辛酸(PFOA)。更重要的是,该设备可以一步提取目标分析物,例如卡马西平(CBZ),从浓缩的砂悬浮液中。提取的CBZ易于使用高效液相色谱分析,无需在提取前去除固体含量。该方法可以应用于药物检测、环境污染监测或食品安全农药残留分析等多个领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Trap-Based Microfluidic Device with Retrivable Droplet for the Analysis of Pollutants from Slurry Solutions.
Liquid-liquid microextraction (LLME) is a cost-effective sample pretreatment method for the analysis of trace analytes in various samples, such as water, blood, urine, and others. In LLME, the high surface area-to-volume ratio of the extractant enables fast accumulation of analytes from the sample into the extractant. The analyte-loaded extractant can easily be analyzed by using common analytical instruments such as liquid or gas chromatography, mass spectrometry, and others. However, a critical drawback of LLME is that when the sample contains solid fragments, microextraction must be preceded by a removal step, which can result in the loss of the analyte and compromise the detection. In this work, we demonstrate microextraction of analytes from a slurry solution without the need for an additional pretreatment step using a trap-based microfluidic device with a retrievable extractant. The extractant, 1-Octanol, is loaded into a microchamber that is in contact with a microchannel that continuously introduces the sample solution. As the solution flows in the microchannel, the intimate contact of the solution with the extractant enables the fast extraction of analytes. Using Nile red (NR) as a model analyte, we demonstrate the influence of the analyte concentration and the flow rate of the sample solution on the extraction. As a proof-of-concept, we show successful extraction of trace amounts of perfluorooctanoic acid (PFOA) from water. More importantly, the device enables one-step extraction of target analytes, e.g., carbamazepine (CBZ), from a concentrated sand suspension. The extracted CBZ is easily analyzed by using high-performance liquid chromatography, eliminating the need to remove the solid content prior to extraction. The approach shown in this work can potentially be applied to various fields, such as drug detection, environmental pollution monitoring, or food safety for pesticide residue analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信