Ying Xiang, Xuan He, Tingting Cheng, Weihao Zhu, Ji Pang, Yijia Cao, Meng Wu, Renjun Pei, Yi Cao
{"title":"两性离子导电水凝胶界面通过高电导率、防污和脑匹配力学增强皮质电成像信号保真度。","authors":"Ying Xiang, Xuan He, Tingting Cheng, Weihao Zhu, Ji Pang, Yijia Cao, Meng Wu, Renjun Pei, Yi Cao","doi":"10.1021/acs.biomac.5c01412","DOIUrl":null,"url":null,"abstract":"<p><p>Electrocorticography (ECoG) holds considerable promise for neural signal monitoring with high spatiotemporal resolution. However, conventional rigid ECoG electrodes are often hampered by poor mechanical compliance and insufficient resistance to biofouling, leading to high interfacial impedance and compromised signal quality. While integrating conductive hydrogels into ECoG interface offers a potential solution, concurrently achieving high conductivity, mechanical compatibility with brain tissue, biosafety, and robust antifouling remains a significant challenge. This study introduces SPP@NaCl, a novel zwitterionic conductive hydrogel synthesized by doping a poly(sulfobetaine methacrylate) (pSB) hydrogel matrix with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and employing NaCl as a Lewis acid to induce phase separation, thereby promoting an interconnected PEDOT network. The resultant SPP@NaCl hydrogel exhibits a compelling combination of properties: high electrical conductivity (∼9 S·m<sup>-</sup><sup>1</sup>), a low Young's modulus (1.74 kPa) that closely matches brain tissue, excellent conformability, and markedly reduced protein adsorption attributable to its zwitterionic structure. When integrated with commercial ECoG electrodes, the optimized SPP@NaCl-8 hydrogel dramatically lowers interfacial impedance. The resulting Au-SPP@NaCl electrodes enabled high-fidelity, real-time monitoring of cortical epileptiform discharges in a rat seizure model and demonstrated stable, long-term neural signal acquisition in anesthetized healthy rats. This work presents a new strategy for constructing ECoG interfaces that simultaneously deliver high conductivity, mechanical compliance, biosafety, and antifouling capabilities, highlighting the significant potential of these hydrogel-integrated ECoG electrodes for advanced brain-computer interface applications.</p>","PeriodicalId":30,"journal":{"name":"Biomacromolecules","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2025-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Zwitterionic Conductive Hydrogel Interface for Enhanced Electrocorticography Signal Fidelity via High Conductivity, Antifouling, and Brain-Matched Mechanics.\",\"authors\":\"Ying Xiang, Xuan He, Tingting Cheng, Weihao Zhu, Ji Pang, Yijia Cao, Meng Wu, Renjun Pei, Yi Cao\",\"doi\":\"10.1021/acs.biomac.5c01412\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Electrocorticography (ECoG) holds considerable promise for neural signal monitoring with high spatiotemporal resolution. However, conventional rigid ECoG electrodes are often hampered by poor mechanical compliance and insufficient resistance to biofouling, leading to high interfacial impedance and compromised signal quality. While integrating conductive hydrogels into ECoG interface offers a potential solution, concurrently achieving high conductivity, mechanical compatibility with brain tissue, biosafety, and robust antifouling remains a significant challenge. This study introduces SPP@NaCl, a novel zwitterionic conductive hydrogel synthesized by doping a poly(sulfobetaine methacrylate) (pSB) hydrogel matrix with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and employing NaCl as a Lewis acid to induce phase separation, thereby promoting an interconnected PEDOT network. The resultant SPP@NaCl hydrogel exhibits a compelling combination of properties: high electrical conductivity (∼9 S·m<sup>-</sup><sup>1</sup>), a low Young's modulus (1.74 kPa) that closely matches brain tissue, excellent conformability, and markedly reduced protein adsorption attributable to its zwitterionic structure. When integrated with commercial ECoG electrodes, the optimized SPP@NaCl-8 hydrogel dramatically lowers interfacial impedance. The resulting Au-SPP@NaCl electrodes enabled high-fidelity, real-time monitoring of cortical epileptiform discharges in a rat seizure model and demonstrated stable, long-term neural signal acquisition in anesthetized healthy rats. This work presents a new strategy for constructing ECoG interfaces that simultaneously deliver high conductivity, mechanical compliance, biosafety, and antifouling capabilities, highlighting the significant potential of these hydrogel-integrated ECoG electrodes for advanced brain-computer interface applications.</p>\",\"PeriodicalId\":30,\"journal\":{\"name\":\"Biomacromolecules\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2025-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomacromolecules\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acs.biomac.5c01412\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomacromolecules","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.biomac.5c01412","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
A Zwitterionic Conductive Hydrogel Interface for Enhanced Electrocorticography Signal Fidelity via High Conductivity, Antifouling, and Brain-Matched Mechanics.
Electrocorticography (ECoG) holds considerable promise for neural signal monitoring with high spatiotemporal resolution. However, conventional rigid ECoG electrodes are often hampered by poor mechanical compliance and insufficient resistance to biofouling, leading to high interfacial impedance and compromised signal quality. While integrating conductive hydrogels into ECoG interface offers a potential solution, concurrently achieving high conductivity, mechanical compatibility with brain tissue, biosafety, and robust antifouling remains a significant challenge. This study introduces SPP@NaCl, a novel zwitterionic conductive hydrogel synthesized by doping a poly(sulfobetaine methacrylate) (pSB) hydrogel matrix with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and employing NaCl as a Lewis acid to induce phase separation, thereby promoting an interconnected PEDOT network. The resultant SPP@NaCl hydrogel exhibits a compelling combination of properties: high electrical conductivity (∼9 S·m-1), a low Young's modulus (1.74 kPa) that closely matches brain tissue, excellent conformability, and markedly reduced protein adsorption attributable to its zwitterionic structure. When integrated with commercial ECoG electrodes, the optimized SPP@NaCl-8 hydrogel dramatically lowers interfacial impedance. The resulting Au-SPP@NaCl electrodes enabled high-fidelity, real-time monitoring of cortical epileptiform discharges in a rat seizure model and demonstrated stable, long-term neural signal acquisition in anesthetized healthy rats. This work presents a new strategy for constructing ECoG interfaces that simultaneously deliver high conductivity, mechanical compliance, biosafety, and antifouling capabilities, highlighting the significant potential of these hydrogel-integrated ECoG electrodes for advanced brain-computer interface applications.
期刊介绍:
Biomacromolecules is a leading forum for the dissemination of cutting-edge research at the interface of polymer science and biology. Submissions to Biomacromolecules should contain strong elements of innovation in terms of macromolecular design, synthesis and characterization, or in the application of polymer materials to biology and medicine.
Topics covered by Biomacromolecules include, but are not exclusively limited to: sustainable polymers, polymers based on natural and renewable resources, degradable polymers, polymer conjugates, polymeric drugs, polymers in biocatalysis, biomacromolecular assembly, biomimetic polymers, polymer-biomineral hybrids, biomimetic-polymer processing, polymer recycling, bioactive polymer surfaces, original polymer design for biomedical applications such as immunotherapy, drug delivery, gene delivery, antimicrobial applications, diagnostic imaging and biosensing, polymers in tissue engineering and regenerative medicine, polymeric scaffolds and hydrogels for cell culture and delivery.