{"title":"dti - alps指数在原生成像空间沿主轴系统自动测定淋巴血流,校正头部和纤维方向。","authors":"Ali Ajouz, Olav Jansen, Lynn Johann Frohwein, Svea Seehafer, Naomi Larsen, Jan-Bernd Hövener","doi":"10.1002/mrm.70082","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this work is to make the DTI along the perivascular space (DTI-ALPS-index) more robust with respect to region selection and the orientation of the head and fibers. We propose to address this matter by using the principal diffusion directions and an automated, atlas-based region of interest (ROI) placement.</p><p><strong>Methods: </strong>Simulations were used to determine the dependence of the DTI-ALPS-index on the orientations of the head and nerve fibers. Human MRI was performed on 12 healthy volunteers at 3T using a 64 channel head coil (Cima.X Siemens), and the DTI-ALPS-index was calculated along the principal diffusion directions (ALPS-PAS) and along the field of view or laboratory frame (ALPS-LAB). To calculate the DTI-ALPS-index with reduced bias in native space, we developed a novel algorithm for an automatic ROI placement technique. Its calculated index results  were compared to those obtained from a manual ROIplacement in native space and from an existing atlas-based ROI placement. Test-retest scans with varying head rotation were conducted for validation.</p><p><strong>Results: </strong>Simulations showed that ALPS-PAS was more robust toward head and fiber rotations than ALPS-LAB. In vivo, ALPS-PAS yielded a 10% higher index than ALPS-LAB. The automated ROI placement led to a smaller difference in the DTI-ALPS-index between test and retest measurement compared to the manual ROI placement. Stability was enhanced with ALPS-PAS for all ROI placements and varying head rotation.</p><p><strong>Conclusion: </strong>Using the principal components of the diffusion and automated ROI selection increased the measured DTI-ALPS-index, improved the robustness toward head and fiber orientations and eliminated the need for manual region selection.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automatic determination of glymphatic flow with the DTI-ALPS-index along the principal axis system in native imaging space corrects for head and fiber orientation.\",\"authors\":\"Ali Ajouz, Olav Jansen, Lynn Johann Frohwein, Svea Seehafer, Naomi Larsen, Jan-Bernd Hövener\",\"doi\":\"10.1002/mrm.70082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this work is to make the DTI along the perivascular space (DTI-ALPS-index) more robust with respect to region selection and the orientation of the head and fibers. We propose to address this matter by using the principal diffusion directions and an automated, atlas-based region of interest (ROI) placement.</p><p><strong>Methods: </strong>Simulations were used to determine the dependence of the DTI-ALPS-index on the orientations of the head and nerve fibers. Human MRI was performed on 12 healthy volunteers at 3T using a 64 channel head coil (Cima.X Siemens), and the DTI-ALPS-index was calculated along the principal diffusion directions (ALPS-PAS) and along the field of view or laboratory frame (ALPS-LAB). To calculate the DTI-ALPS-index with reduced bias in native space, we developed a novel algorithm for an automatic ROI placement technique. Its calculated index results  were compared to those obtained from a manual ROIplacement in native space and from an existing atlas-based ROI placement. Test-retest scans with varying head rotation were conducted for validation.</p><p><strong>Results: </strong>Simulations showed that ALPS-PAS was more robust toward head and fiber rotations than ALPS-LAB. In vivo, ALPS-PAS yielded a 10% higher index than ALPS-LAB. The automated ROI placement led to a smaller difference in the DTI-ALPS-index between test and retest measurement compared to the manual ROI placement. Stability was enhanced with ALPS-PAS for all ROI placements and varying head rotation.</p><p><strong>Conclusion: </strong>Using the principal components of the diffusion and automated ROI selection increased the measured DTI-ALPS-index, improved the robustness toward head and fiber orientations and eliminated the need for manual region selection.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/mrm.70082\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.70082","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:这项工作的目的是使沿血管周围空间的DTI (DTI- alps指数)在区域选择和头部和纤维的方向方面更加稳健。我们建议通过使用主要扩散方向和自动的、基于地图集的兴趣区域(ROI)放置来解决这个问题。方法:采用模拟方法确定dti - alps指数对头部和神经纤维方向的依赖性。12名健康志愿者在3T时使用64通道头线圈(Cima)进行人体MRI。X Siemens),沿主要扩散方向(ALPS-PAS)和视场或实验室框架(ALPS-LAB)计算dti - alps指数。为了在本地空间中计算具有较小偏差的dti - alps指数,我们开发了一种新的ROI自动放置技术算法。将其计算的指数结果与在原始空间中手动ROI置换和现有基于地图集的ROI置换所获得的结果进行了比较。进行不同头部旋转的测试-重测试扫描以进行验证。结果:模拟结果表明,ALPS-PAS对头部和纤维旋转的鲁棒性比ALPS-LAB更强。在体内,ALPS-PAS的指数比ALPS-LAB高10%。与手动ROI放置相比,自动化ROI放置导致测试和重新测试测量之间的dti - alps指数差异较小。使用ALPS-PAS增强了所有ROI位置和不同头部旋转的稳定性。结论:使用扩散主成分和自动ROI选择增加了测量的dti - alps指数,提高了对头部和纤维方向的鲁棒性,消除了手动区域选择的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic determination of glymphatic flow with the DTI-ALPS-index along the principal axis system in native imaging space corrects for head and fiber orientation.

Purpose: The aim of this work is to make the DTI along the perivascular space (DTI-ALPS-index) more robust with respect to region selection and the orientation of the head and fibers. We propose to address this matter by using the principal diffusion directions and an automated, atlas-based region of interest (ROI) placement.

Methods: Simulations were used to determine the dependence of the DTI-ALPS-index on the orientations of the head and nerve fibers. Human MRI was performed on 12 healthy volunteers at 3T using a 64 channel head coil (Cima.X Siemens), and the DTI-ALPS-index was calculated along the principal diffusion directions (ALPS-PAS) and along the field of view or laboratory frame (ALPS-LAB). To calculate the DTI-ALPS-index with reduced bias in native space, we developed a novel algorithm for an automatic ROI placement technique. Its calculated index results  were compared to those obtained from a manual ROIplacement in native space and from an existing atlas-based ROI placement. Test-retest scans with varying head rotation were conducted for validation.

Results: Simulations showed that ALPS-PAS was more robust toward head and fiber rotations than ALPS-LAB. In vivo, ALPS-PAS yielded a 10% higher index than ALPS-LAB. The automated ROI placement led to a smaller difference in the DTI-ALPS-index between test and retest measurement compared to the manual ROI placement. Stability was enhanced with ALPS-PAS for all ROI placements and varying head rotation.

Conclusion: Using the principal components of the diffusion and automated ROI selection increased the measured DTI-ALPS-index, improved the robustness toward head and fiber orientations and eliminated the need for manual region selection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信