同时电化学检测茶碱和甲基多巴药物的新型Fe3O4-IL/CPE纳米传感器

IF 4.9 Q1 CHEMISTRY, ANALYTICAL
Seyed Karim Hassaninejad-Darzi, Ali Ahangar-Samakosh, Fatemeh Aran-Dinaki, Mohammad Asadollahi-Baboli
{"title":"同时电化学检测茶碱和甲基多巴药物的新型Fe3O4-IL/CPE纳米传感器","authors":"Seyed Karim Hassaninejad-Darzi,&nbsp;Ali Ahangar-Samakosh,&nbsp;Fatemeh Aran-Dinaki,&nbsp;Mohammad Asadollahi-Baboli","doi":"10.1016/j.sbsr.2025.100889","DOIUrl":null,"url":null,"abstract":"<div><div>Simultaneous determination of methyldopa (MD), and theophylline (THEO) drugs was developed by a modified carbon paste electrode (CPE) with magnetite iron oxide nanostructure and imidazolium ionic liquid (IL). The obtained results displayed that the Fe<sub>3</sub>O<sub>4</sub>-IL/CPE showed higher oxidation currents versus bare CPE and other modified electrodes. The pH 3.0 for PBS, temperature 34 °C, IL 5.0 %, and Fe<sub>3</sub>O<sub>4</sub> 9.0 % in the fabricated sensor were developed as the maximum anodic currents. In the above optimal conditions, the linear responses with the DPV technique were attained in the 2.72–180.32 μM and 7.64–137.93 μM for MD and THEO, respectively. Also, the LOD of 0.90 and 2.52 μM were obtained for MD and THEO, respectively. We, also considered measurement of MD and THEO drugs in human plasma and mixtures of tablets as a real sample and the results show a good recovery percentage.</div></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"50 ","pages":"Article 100889"},"PeriodicalIF":4.9000,"publicationDate":"2025-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cost-effective and novel Fe3O4-IL/CPE nanosensor for simultaneous electrochemical detection of theophylline and methyldopa drugs\",\"authors\":\"Seyed Karim Hassaninejad-Darzi,&nbsp;Ali Ahangar-Samakosh,&nbsp;Fatemeh Aran-Dinaki,&nbsp;Mohammad Asadollahi-Baboli\",\"doi\":\"10.1016/j.sbsr.2025.100889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Simultaneous determination of methyldopa (MD), and theophylline (THEO) drugs was developed by a modified carbon paste electrode (CPE) with magnetite iron oxide nanostructure and imidazolium ionic liquid (IL). The obtained results displayed that the Fe<sub>3</sub>O<sub>4</sub>-IL/CPE showed higher oxidation currents versus bare CPE and other modified electrodes. The pH 3.0 for PBS, temperature 34 °C, IL 5.0 %, and Fe<sub>3</sub>O<sub>4</sub> 9.0 % in the fabricated sensor were developed as the maximum anodic currents. In the above optimal conditions, the linear responses with the DPV technique were attained in the 2.72–180.32 μM and 7.64–137.93 μM for MD and THEO, respectively. Also, the LOD of 0.90 and 2.52 μM were obtained for MD and THEO, respectively. We, also considered measurement of MD and THEO drugs in human plasma and mixtures of tablets as a real sample and the results show a good recovery percentage.</div></div>\",\"PeriodicalId\":424,\"journal\":{\"name\":\"Sensing and Bio-Sensing Research\",\"volume\":\"50 \",\"pages\":\"Article 100889\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensing and Bio-Sensing Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214180425001552\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214180425001552","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

采用磁性氧化铁纳米结构和咪唑离子液体修饰碳糊电极(CPE),建立了同时测定甲基多巴(MD)和茶碱(THEO)药物的方法。结果表明,Fe3O4-IL/CPE比裸CPE和其他修饰电极具有更高的氧化电流。在PBS溶液pH 3.0,温度34℃,IL 5.0 %, Fe3O4 9.0 %的条件下,传感器的最大阳极电流为。在此优化条件下,DPV技术对MD和THEO的线性响应范围分别为2.72 ~ 180.32 μM和7.64 ~ 137.93 μM。MD和THEO的LOD分别为0.90 μM和2.52 μM。我们还考虑了在人血浆和片剂混合物中测定MD和THEO药物作为真实样品,结果显示出良好的回收率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Cost-effective and novel Fe3O4-IL/CPE nanosensor for simultaneous electrochemical detection of theophylline and methyldopa drugs

Cost-effective and novel Fe3O4-IL/CPE nanosensor for simultaneous electrochemical detection of theophylline and methyldopa drugs
Simultaneous determination of methyldopa (MD), and theophylline (THEO) drugs was developed by a modified carbon paste electrode (CPE) with magnetite iron oxide nanostructure and imidazolium ionic liquid (IL). The obtained results displayed that the Fe3O4-IL/CPE showed higher oxidation currents versus bare CPE and other modified electrodes. The pH 3.0 for PBS, temperature 34 °C, IL 5.0 %, and Fe3O4 9.0 % in the fabricated sensor were developed as the maximum anodic currents. In the above optimal conditions, the linear responses with the DPV technique were attained in the 2.72–180.32 μM and 7.64–137.93 μM for MD and THEO, respectively. Also, the LOD of 0.90 and 2.52 μM were obtained for MD and THEO, respectively. We, also considered measurement of MD and THEO drugs in human plasma and mixtures of tablets as a real sample and the results show a good recovery percentage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensing and Bio-Sensing Research
Sensing and Bio-Sensing Research Engineering-Electrical and Electronic Engineering
CiteScore
10.70
自引率
3.80%
发文量
68
审稿时长
87 days
期刊介绍: Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies. The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信