使用可拉伸应变传感器的新型单侧胸廓扩张测量的重测可靠性。

Motoki Yamanaka, Kazuki Yamaguchi, Keiji Asada
{"title":"使用可拉伸应变传感器的新型单侧胸廓扩张测量的重测可靠性。","authors":"Motoki Yamanaka, Kazuki Yamaguchi, Keiji Asada","doi":"10.1589/jpts.37.519","DOIUrl":null,"url":null,"abstract":"<p><p>[Purpose] We report here a new method for measuring unilateral thoracic expansion using stretchable strain sensors. In this study, we assessed the test-retest reliability of this method and compared left and right thoracic expansions in healthy males. [Participants and Methods] Thirty healthy males (mean age, 30.1 ± 7.4 years) participated in this study. Two strain sensors were placed on the lateral walls of the thorax at xiphoid process level. Participants were asked to take three deep breaths, and the change in sensor length from the position at maximal expiration to that at maximal inspiration was recorded. These measurements were simultaneously performed on left and right sides. Unilateral thoracic expansions were calculated to assess differences between the maximal expiratory and inspiratory positions for each deep breath. The test-retest reliability of the unilateral thoracic expansion was then examined. [Results] Test reliability was excellent for both first and second datasets. Retest reliability was also excellent. The minimum detectable change (MDC) in the retest was 3.31 mm. [Conclusion] This newly developed method for measuring thoracic expansion is sufficiently reliable. No differences in thoracic expansion were observed between left and right sides in healthy males.</p>","PeriodicalId":16834,"journal":{"name":"Journal of Physical Therapy Science","volume":"37 10","pages":"519-523"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12483484/pdf/","citationCount":"0","resultStr":"{\"title\":\"Test-retest reliability of a novel unilateral thoracic expansion measurement using stretchable strain sensors.\",\"authors\":\"Motoki Yamanaka, Kazuki Yamaguchi, Keiji Asada\",\"doi\":\"10.1589/jpts.37.519\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>[Purpose] We report here a new method for measuring unilateral thoracic expansion using stretchable strain sensors. In this study, we assessed the test-retest reliability of this method and compared left and right thoracic expansions in healthy males. [Participants and Methods] Thirty healthy males (mean age, 30.1 ± 7.4 years) participated in this study. Two strain sensors were placed on the lateral walls of the thorax at xiphoid process level. Participants were asked to take three deep breaths, and the change in sensor length from the position at maximal expiration to that at maximal inspiration was recorded. These measurements were simultaneously performed on left and right sides. Unilateral thoracic expansions were calculated to assess differences between the maximal expiratory and inspiratory positions for each deep breath. The test-retest reliability of the unilateral thoracic expansion was then examined. [Results] Test reliability was excellent for both first and second datasets. Retest reliability was also excellent. The minimum detectable change (MDC) in the retest was 3.31 mm. [Conclusion] This newly developed method for measuring thoracic expansion is sufficiently reliable. No differences in thoracic expansion were observed between left and right sides in healthy males.</p>\",\"PeriodicalId\":16834,\"journal\":{\"name\":\"Journal of Physical Therapy Science\",\"volume\":\"37 10\",\"pages\":\"519-523\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12483484/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physical Therapy Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1589/jpts.37.519\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physical Therapy Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1589/jpts.37.519","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

【目的】本文报道了一种使用可拉伸应变传感器测量单侧胸部扩张的新方法。在这项研究中,我们评估了该方法的重测可靠性,并比较了健康男性的左右胸扩张。【对象与方法】健康男性30例,平均年龄30.1±7.4岁。在剑突水平的胸壁外侧放置两个应变传感器。参与者被要求进行三次深呼吸,并记录下从最大呼气位置到最大吸气位置的传感器长度变化。这些测量是在左右两侧同时进行的。计算单侧胸腔扩张以评估每次深呼吸时最大呼气位和最大吸气位之间的差异。然后检查单侧胸廓扩张的重测信度。[结果]第一和第二数据集的测试信度都很好。重测信度也很好。复测的最小可检测变化(MDC)为3.31 mm。[结论]这种新方法测量胸廓扩张是足够可靠的。健康男性的左右两侧胸廓扩张无差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Test-retest reliability of a novel unilateral thoracic expansion measurement using stretchable strain sensors.

[Purpose] We report here a new method for measuring unilateral thoracic expansion using stretchable strain sensors. In this study, we assessed the test-retest reliability of this method and compared left and right thoracic expansions in healthy males. [Participants and Methods] Thirty healthy males (mean age, 30.1 ± 7.4 years) participated in this study. Two strain sensors were placed on the lateral walls of the thorax at xiphoid process level. Participants were asked to take three deep breaths, and the change in sensor length from the position at maximal expiration to that at maximal inspiration was recorded. These measurements were simultaneously performed on left and right sides. Unilateral thoracic expansions were calculated to assess differences between the maximal expiratory and inspiratory positions for each deep breath. The test-retest reliability of the unilateral thoracic expansion was then examined. [Results] Test reliability was excellent for both first and second datasets. Retest reliability was also excellent. The minimum detectable change (MDC) in the retest was 3.31 mm. [Conclusion] This newly developed method for measuring thoracic expansion is sufficiently reliable. No differences in thoracic expansion were observed between left and right sides in healthy males.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
137
审稿时长
4-8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信