心电图LVH标准:即使使用优化的截止值,诊断准确性也较差。来自MESA研究的见解。

IF 1.2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
José Nunes de Alencar , Sandro Pinelli Felicioni
{"title":"心电图LVH标准:即使使用优化的截止值,诊断准确性也较差。来自MESA研究的见解。","authors":"José Nunes de Alencar ,&nbsp;Sandro Pinelli Felicioni","doi":"10.1016/j.jelectrocard.2025.154138","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Electrocardiographic (ECG) “left ventricular hypertrophy (LVH) criteria” are widely used as surrogates for increased LV mass but show limited sensitivity. We evaluated their diagnostic performance against cardiac magnetic resonance (CMR) in a large population cohort.</div></div><div><h3>Methods</h3><div>We analyzed 4849 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) with standardized digital 12‑lead ECGs and CMR-derived LV mass indexed to body surface area (LVMi). LVH was defined as LVMi &gt;91 g/m<sup>2</sup> (men) and &gt; 77 g/m<sup>2</sup> (women). We assessed Sokolow-Lyon, Cornell voltage, Cornell product, Peguero–Lo Presti, Sokolow-aVL, and MESA-LVH (SV1 + SV2 + RV5). Diagnostic accuracy was calculated for classic (“pre-specified”) thresholds and for cutoffs optimized by the Youden index. We also tested whether combining indices via elastic-net penalized logistic regression improved discrimination.</div></div><div><h3>Results</h3><div>LVH prevalence was 30.2 %. Across classic thresholds, sensitivities were very low (3.7–15.2 %) with high specificities (&gt;94 %); likelihood ratios were modest (typical LR+ &lt;4; LR− ≈ 0.89–0.96). Youden-optimized cutoffs improved sensitivity (48.9–64.8 %) at the expense of specificity (54.4–74.3 %), yielding weak LR+ (1.42–1.94) and LR− (0.64–0.71). Pooled area under the ROC curve (AUC) for individual indices ranged 0.62–0.66. An elastic-net model combining all indices did not enhance discrimination beyond the best single measure (AUC 0.646).</div></div><div><h3>Conclusions</h3><div>In MESA, ECG voltage criteria—whether applied at classic or optimized thresholds—show poor diagnostic performance for CMR-defined LVH. Aggregating indices provides no material gain. These findings support reframing voltage positivity as an amplitude-based electrical phenotype with prognostic value rather than a reliable diagnostic surrogate for structural hypertrophy.</div></div><div><h3>Clinical trial registration</h3><div><span><span>ClinicalTrials.gov</span><svg><path></path></svg></span> Identifier <span><span>NCT00005487</span><svg><path></path></svg></span>.</div></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":"93 ","pages":"Article 154138"},"PeriodicalIF":1.2000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrocardiographic LVH criteria: Poor diagnostic accuracy even with optimized cutoffs. Insights from MESA study\",\"authors\":\"José Nunes de Alencar ,&nbsp;Sandro Pinelli Felicioni\",\"doi\":\"10.1016/j.jelectrocard.2025.154138\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Electrocardiographic (ECG) “left ventricular hypertrophy (LVH) criteria” are widely used as surrogates for increased LV mass but show limited sensitivity. We evaluated their diagnostic performance against cardiac magnetic resonance (CMR) in a large population cohort.</div></div><div><h3>Methods</h3><div>We analyzed 4849 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) with standardized digital 12‑lead ECGs and CMR-derived LV mass indexed to body surface area (LVMi). LVH was defined as LVMi &gt;91 g/m<sup>2</sup> (men) and &gt; 77 g/m<sup>2</sup> (women). We assessed Sokolow-Lyon, Cornell voltage, Cornell product, Peguero–Lo Presti, Sokolow-aVL, and MESA-LVH (SV1 + SV2 + RV5). Diagnostic accuracy was calculated for classic (“pre-specified”) thresholds and for cutoffs optimized by the Youden index. We also tested whether combining indices via elastic-net penalized logistic regression improved discrimination.</div></div><div><h3>Results</h3><div>LVH prevalence was 30.2 %. Across classic thresholds, sensitivities were very low (3.7–15.2 %) with high specificities (&gt;94 %); likelihood ratios were modest (typical LR+ &lt;4; LR− ≈ 0.89–0.96). Youden-optimized cutoffs improved sensitivity (48.9–64.8 %) at the expense of specificity (54.4–74.3 %), yielding weak LR+ (1.42–1.94) and LR− (0.64–0.71). Pooled area under the ROC curve (AUC) for individual indices ranged 0.62–0.66. An elastic-net model combining all indices did not enhance discrimination beyond the best single measure (AUC 0.646).</div></div><div><h3>Conclusions</h3><div>In MESA, ECG voltage criteria—whether applied at classic or optimized thresholds—show poor diagnostic performance for CMR-defined LVH. Aggregating indices provides no material gain. These findings support reframing voltage positivity as an amplitude-based electrical phenotype with prognostic value rather than a reliable diagnostic surrogate for structural hypertrophy.</div></div><div><h3>Clinical trial registration</h3><div><span><span>ClinicalTrials.gov</span><svg><path></path></svg></span> Identifier <span><span>NCT00005487</span><svg><path></path></svg></span>.</div></div>\",\"PeriodicalId\":15606,\"journal\":{\"name\":\"Journal of electrocardiology\",\"volume\":\"93 \",\"pages\":\"Article 154138\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2025-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of electrocardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022073625002663\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073625002663","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:心电图(ECG)“左室肥厚(LVH)标准”被广泛用作左室重量增加的替代指标,但其敏感性有限。我们在一个大型人群队列中评估了它们对心脏磁共振(CMR)的诊断性能。方法:我们分析了4849名来自多民族动脉粥样硬化研究(MESA)的参与者,使用标准化的数字12导联心电图和cmr衍生的左室质量与体表面积(LVMi)指数。LVH的定义为LVMi >91 g/m2(男性)和> 77 g/m2(女性)。我们评估了Sokolow-Lyon、Cornell voltage、Cornell product、Peguero-Lo Presti、Sokolow-aVL和MESA-LVH (SV1 + SV2 + RV5)。根据经典(“预先指定的”)阈值和由约登指数优化的截止值计算诊断准确性。我们还测试了通过弹性网络惩罚逻辑回归组合指数是否能改善歧视。结果:LVH患病率为30.2%。在经典阈值上,敏感性非常低(3.7- 15.2%),特异性很高(bb0 - 94%);结论:在MESA中,ECG电压标准——无论是应用于经典阈值还是优化阈值——对cmr定义的LVH的诊断性能较差。汇总指数不会带来实质收益。这些发现支持将电压阳性重构为具有预后价值的基于振幅的电表型,而不是结构肥大的可靠诊断替代品。临床试验注册:ClinicalTrials.gov标识符NCT00005487。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrocardiographic LVH criteria: Poor diagnostic accuracy even with optimized cutoffs. Insights from MESA study

Background

Electrocardiographic (ECG) “left ventricular hypertrophy (LVH) criteria” are widely used as surrogates for increased LV mass but show limited sensitivity. We evaluated their diagnostic performance against cardiac magnetic resonance (CMR) in a large population cohort.

Methods

We analyzed 4849 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) with standardized digital 12‑lead ECGs and CMR-derived LV mass indexed to body surface area (LVMi). LVH was defined as LVMi >91 g/m2 (men) and > 77 g/m2 (women). We assessed Sokolow-Lyon, Cornell voltage, Cornell product, Peguero–Lo Presti, Sokolow-aVL, and MESA-LVH (SV1 + SV2 + RV5). Diagnostic accuracy was calculated for classic (“pre-specified”) thresholds and for cutoffs optimized by the Youden index. We also tested whether combining indices via elastic-net penalized logistic regression improved discrimination.

Results

LVH prevalence was 30.2 %. Across classic thresholds, sensitivities were very low (3.7–15.2 %) with high specificities (>94 %); likelihood ratios were modest (typical LR+ <4; LR− ≈ 0.89–0.96). Youden-optimized cutoffs improved sensitivity (48.9–64.8 %) at the expense of specificity (54.4–74.3 %), yielding weak LR+ (1.42–1.94) and LR− (0.64–0.71). Pooled area under the ROC curve (AUC) for individual indices ranged 0.62–0.66. An elastic-net model combining all indices did not enhance discrimination beyond the best single measure (AUC 0.646).

Conclusions

In MESA, ECG voltage criteria—whether applied at classic or optimized thresholds—show poor diagnostic performance for CMR-defined LVH. Aggregating indices provides no material gain. These findings support reframing voltage positivity as an amplitude-based electrical phenotype with prognostic value rather than a reliable diagnostic surrogate for structural hypertrophy.

Clinical trial registration

ClinicalTrials.gov Identifier NCT00005487.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信