12-磷钨酸-杯芳烃复合固体电解质的酸铵盐电位测量H2和CO传感器

IF 0.8 4区 工程技术 Q4 ELECTROCHEMISTRY
L. V. Shmygleva, A. S. Ovsyannikova, A. V. Vinyukov, L. S. Leonova
{"title":"12-磷钨酸-杯芳烃复合固体电解质的酸铵盐电位测量H2和CO传感器","authors":"L. V. Shmygleva,&nbsp;A. S. Ovsyannikova,&nbsp;A. V. Vinyukov,&nbsp;L. S. Leonova","doi":"10.1134/S1023193525600270","DOIUrl":null,"url":null,"abstract":"<p>The work is focused on the analysis the impact of the composition of a composite electrolyte comprising a disubstituted ammonium salt of phosphotungstic acid and sulfonated calixarene on the characteristics of solid-state potentiometric sensors for hydrogen and carbon monoxide, including their simultaneous detection in air. The response time of the CO sensors is shown to be independent of the composition of the composite electrolyte, with a value of approximately two minutes for 0.1 vol %. The study also observed two types of open circuit voltage, depending on the electrolyte composition. The sensors demonstrated selectivity for CO, detecting it in the H<sub>2</sub>–CO–air atmosphere at concentrations comparable to H<sub>2</sub> concentrations.</p>","PeriodicalId":760,"journal":{"name":"Russian Journal of Electrochemistry","volume":"61 7","pages":"322 - 332"},"PeriodicalIF":0.8000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Acid Ammonium Salt of 12-Phosphotungstic Acid and Calixarene Composite Solid Electrolytes for Potentiometric H2 and CO Sensors\",\"authors\":\"L. V. Shmygleva,&nbsp;A. S. Ovsyannikova,&nbsp;A. V. Vinyukov,&nbsp;L. S. Leonova\",\"doi\":\"10.1134/S1023193525600270\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The work is focused on the analysis the impact of the composition of a composite electrolyte comprising a disubstituted ammonium salt of phosphotungstic acid and sulfonated calixarene on the characteristics of solid-state potentiometric sensors for hydrogen and carbon monoxide, including their simultaneous detection in air. The response time of the CO sensors is shown to be independent of the composition of the composite electrolyte, with a value of approximately two minutes for 0.1 vol %. The study also observed two types of open circuit voltage, depending on the electrolyte composition. The sensors demonstrated selectivity for CO, detecting it in the H<sub>2</sub>–CO–air atmosphere at concentrations comparable to H<sub>2</sub> concentrations.</p>\",\"PeriodicalId\":760,\"journal\":{\"name\":\"Russian Journal of Electrochemistry\",\"volume\":\"61 7\",\"pages\":\"322 - 332\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Russian Journal of Electrochemistry\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1023193525600270\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Electrochemistry","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S1023193525600270","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

研究了磷钨酸二取代铵盐和磺化杯芳烃复合电解质的组成对氢和一氧化碳固态电位传感器特性的影响,包括它们在空气中的同时检测。CO传感器的响应时间与复合电解质的组成无关,对于0.1 vol %,其值约为2分钟。该研究还观察到两种类型的开路电压,这取决于电解质成分。传感器显示了对CO的选择性,在浓度与H2浓度相当的H2 - CO -空气中检测到它。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Acid Ammonium Salt of 12-Phosphotungstic Acid and Calixarene Composite Solid Electrolytes for Potentiometric H2 and CO Sensors

Acid Ammonium Salt of 12-Phosphotungstic Acid and Calixarene Composite Solid Electrolytes for Potentiometric H2 and CO Sensors

The work is focused on the analysis the impact of the composition of a composite electrolyte comprising a disubstituted ammonium salt of phosphotungstic acid and sulfonated calixarene on the characteristics of solid-state potentiometric sensors for hydrogen and carbon monoxide, including their simultaneous detection in air. The response time of the CO sensors is shown to be independent of the composition of the composite electrolyte, with a value of approximately two minutes for 0.1 vol %. The study also observed two types of open circuit voltage, depending on the electrolyte composition. The sensors demonstrated selectivity for CO, detecting it in the H2–CO–air atmosphere at concentrations comparable to H2 concentrations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Russian Journal of Electrochemistry
Russian Journal of Electrochemistry 工程技术-电化学
CiteScore
1.90
自引率
8.30%
发文量
102
审稿时长
6 months
期刊介绍: Russian Journal of Electrochemistry is a journal that covers all aspects of research in modern electrochemistry. The journal welcomes submissions in English or Russian regardless of country and nationality of authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信