{"title":"用高时间分辨率MC-ICP-MS分析单个粒子中208Pb/232Th比揭示飞秒激光烧蚀过程中元素分异机理","authors":"Sota Niki and Takafumi Hirata","doi":"10.1039/D5JA00016E","DOIUrl":null,"url":null,"abstract":"<p >This study investigated the mechanism of elemental fractionation during laser ablation (LA) through elemental analysis of individual particles generated <em>via</em> femtosecond laser ablation (fsLA) using a minimised laser spot size of approximately 2 μm. Data acquisition was conducted within a short dwell time of 20 μs using a multiple collector-ICP-mass spectrometer equipped with a high-time-resolution ion counting system (HTR-MC-ICP-MS), which avoids the overlap of signal events from multiple particles. Results obtained from monazite references showed that individual fsLA-generated particles fall into two distinct groups in terms of <small><sup>208</sup></small>Pb/<small><sup>232</sup></small>Th: Pb-bearing (volatile-element-rich) <em>vs.</em> Pb-depleted (volatile-element-poor). The existence of these two populations is probably the major cause of elemental fractionation in LA. This decoupling is attributed to the different behaviours of volatile and refractory elements during particle generation. Particles that condense from laser-induced vapor plume tend to retain volatile elements (<em>e.g.</em>, Pb), whereas particles originating from the molten rim of the ablation pit (material that was molten but not vaporized) are depleted in volatile elements. The data obtained here clearly demonstrated that elemental fractionation is involved in the particle generation process, and hence, using matrix-matched reference materials is essential for obtaining reliable elemental data in LA-ICP-MS.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 10","pages":" 2716-2724"},"PeriodicalIF":3.1000,"publicationDate":"2025-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanism of elemental fractionation during femtosecond laser ablation revealed by high-time-resolution MC-ICP-MS analysis of 208Pb/232Th ratios in single particles\",\"authors\":\"Sota Niki and Takafumi Hirata\",\"doi\":\"10.1039/D5JA00016E\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >This study investigated the mechanism of elemental fractionation during laser ablation (LA) through elemental analysis of individual particles generated <em>via</em> femtosecond laser ablation (fsLA) using a minimised laser spot size of approximately 2 μm. Data acquisition was conducted within a short dwell time of 20 μs using a multiple collector-ICP-mass spectrometer equipped with a high-time-resolution ion counting system (HTR-MC-ICP-MS), which avoids the overlap of signal events from multiple particles. Results obtained from monazite references showed that individual fsLA-generated particles fall into two distinct groups in terms of <small><sup>208</sup></small>Pb/<small><sup>232</sup></small>Th: Pb-bearing (volatile-element-rich) <em>vs.</em> Pb-depleted (volatile-element-poor). The existence of these two populations is probably the major cause of elemental fractionation in LA. This decoupling is attributed to the different behaviours of volatile and refractory elements during particle generation. Particles that condense from laser-induced vapor plume tend to retain volatile elements (<em>e.g.</em>, Pb), whereas particles originating from the molten rim of the ablation pit (material that was molten but not vaporized) are depleted in volatile elements. The data obtained here clearly demonstrated that elemental fractionation is involved in the particle generation process, and hence, using matrix-matched reference materials is essential for obtaining reliable elemental data in LA-ICP-MS.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 10\",\"pages\":\" 2716-2724\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d5ja00016e\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ja/d5ja00016e","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Mechanism of elemental fractionation during femtosecond laser ablation revealed by high-time-resolution MC-ICP-MS analysis of 208Pb/232Th ratios in single particles
This study investigated the mechanism of elemental fractionation during laser ablation (LA) through elemental analysis of individual particles generated via femtosecond laser ablation (fsLA) using a minimised laser spot size of approximately 2 μm. Data acquisition was conducted within a short dwell time of 20 μs using a multiple collector-ICP-mass spectrometer equipped with a high-time-resolution ion counting system (HTR-MC-ICP-MS), which avoids the overlap of signal events from multiple particles. Results obtained from monazite references showed that individual fsLA-generated particles fall into two distinct groups in terms of 208Pb/232Th: Pb-bearing (volatile-element-rich) vs. Pb-depleted (volatile-element-poor). The existence of these two populations is probably the major cause of elemental fractionation in LA. This decoupling is attributed to the different behaviours of volatile and refractory elements during particle generation. Particles that condense from laser-induced vapor plume tend to retain volatile elements (e.g., Pb), whereas particles originating from the molten rim of the ablation pit (material that was molten but not vaporized) are depleted in volatile elements. The data obtained here clearly demonstrated that elemental fractionation is involved in the particle generation process, and hence, using matrix-matched reference materials is essential for obtaining reliable elemental data in LA-ICP-MS.