[扫描辅助材料和桩位参数对口内扫描仪桩位准确性的影响:一项体外研究]。

Q4 Medicine
J B Zou, K Huang, L Yin
{"title":"[扫描辅助材料和桩位参数对口内扫描仪桩位准确性的影响:一项体外研究]。","authors":"J B Zou, K Huang, L Yin","doi":"10.3760/cma.j.cn112144-20250426-00156","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To investigate the effects of different post space parameters and scanning aid material on the trueness of digital impressions of post spaces obtained by two intraoral scanners, thereby providing a reference for clinically determining the conditions under which post spaces are suitable for digital impression technology. <b>Methods:</b> This study varied three variables of post space models of residual crowns: opening diameter, post space depth and adjacent tooth status,with specific settings: opening diameter were set at two levels (2.0 and 2.5 mm);post space depth was set at three levels (8.0, 10.0, and 12.0 mm); and adjacent tooth status were set at three levels [bilateral adjacent teeth present (A), unilateral adjacent tooth present (B), and bilateral adjacent teeth absent (C)]. A total of 18 model groups were prepared. Eighteen samples were printed using a three-dimensional printing instrument. Combined with scanning aid material, direct <i>in vitro</i> scanning of these post space models was performed using intraoral scanners (IOS) A (Trios 5) and B (Primescan connect), with 10 replicates per group (<i>n</i>=10). The scanned data were sequentially imported into reverse engineering software. The original design data of the models served as true values, and best-fit comparisons were performed. By calculating the average root mean square error (RMSE) values, the trueness of digital impressions of post spaces with different morphologies obtained by the two scanners was evaluated, both with and without the use of scanning aid material. <b>Results:</b> Under the experimental conditions set in this study, for IOS A, only the sample groups with opening diameter-post space depth-adjacent tooth status combinations of (2.0 8.0 ABC, 2.5 8.0 ABC, 2.5-10.0-ABC) could be identified, with RMSE results ranging from 46.5 to 365.0 μm. After adding scanning aid materials,RMSE results ranging from 46.0 to 185.0 μm, the trueness of the sample groups (2.0-8.0-A, 2.5-10.0-A) was significantly improved by more than 100 μm, and an additional sample group (2.5-12.0-C) could be identified. For IOS B, the identifiable sample groups included all 18 sample groups, with RMSE results ranging from 38.8 to 106.0 μm. After the addition of scanning aid materials, RMSE results ranging from 37.6 to 110.2 μm, the identifiable sample groups remained unchanged. Post space opening diameter, post space depth, and adjacent tooth status all had significant effects on the trueness of post space digital impressions for both IOS A and IOS B (<i>P</i><0.05). Scanning aid materials had a significant effect on IOS A (<i>P</i><0.05) but no significant effect on IOS B (<i>P</i>>0.05). <b>Conclusions:</b> IOS B exhibited superior post space scanning performance compared to IOS A, and its trueness for clinically common post spaces could meet clinical requirements. IOS A has certain requirements for post space opening diameter, post space depth, and adjacent tooth status. For narrow and long post spaces, scanning aid materials can be used to improve the scanning trueness.</p>","PeriodicalId":23965,"journal":{"name":"中华口腔医学杂志","volume":"60 10","pages":"1144-1151"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Influence of scanning aid material and post space parameters on the trueness of intraoral scanners for post space: an <i>in vitro</i> study].\",\"authors\":\"J B Zou, K Huang, L Yin\",\"doi\":\"10.3760/cma.j.cn112144-20250426-00156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To investigate the effects of different post space parameters and scanning aid material on the trueness of digital impressions of post spaces obtained by two intraoral scanners, thereby providing a reference for clinically determining the conditions under which post spaces are suitable for digital impression technology. <b>Methods:</b> This study varied three variables of post space models of residual crowns: opening diameter, post space depth and adjacent tooth status,with specific settings: opening diameter were set at two levels (2.0 and 2.5 mm);post space depth was set at three levels (8.0, 10.0, and 12.0 mm); and adjacent tooth status were set at three levels [bilateral adjacent teeth present (A), unilateral adjacent tooth present (B), and bilateral adjacent teeth absent (C)]. A total of 18 model groups were prepared. Eighteen samples were printed using a three-dimensional printing instrument. Combined with scanning aid material, direct <i>in vitro</i> scanning of these post space models was performed using intraoral scanners (IOS) A (Trios 5) and B (Primescan connect), with 10 replicates per group (<i>n</i>=10). The scanned data were sequentially imported into reverse engineering software. The original design data of the models served as true values, and best-fit comparisons were performed. By calculating the average root mean square error (RMSE) values, the trueness of digital impressions of post spaces with different morphologies obtained by the two scanners was evaluated, both with and without the use of scanning aid material. <b>Results:</b> Under the experimental conditions set in this study, for IOS A, only the sample groups with opening diameter-post space depth-adjacent tooth status combinations of (2.0 8.0 ABC, 2.5 8.0 ABC, 2.5-10.0-ABC) could be identified, with RMSE results ranging from 46.5 to 365.0 μm. After adding scanning aid materials,RMSE results ranging from 46.0 to 185.0 μm, the trueness of the sample groups (2.0-8.0-A, 2.5-10.0-A) was significantly improved by more than 100 μm, and an additional sample group (2.5-12.0-C) could be identified. For IOS B, the identifiable sample groups included all 18 sample groups, with RMSE results ranging from 38.8 to 106.0 μm. After the addition of scanning aid materials, RMSE results ranging from 37.6 to 110.2 μm, the identifiable sample groups remained unchanged. Post space opening diameter, post space depth, and adjacent tooth status all had significant effects on the trueness of post space digital impressions for both IOS A and IOS B (<i>P</i><0.05). Scanning aid materials had a significant effect on IOS A (<i>P</i><0.05) but no significant effect on IOS B (<i>P</i>>0.05). <b>Conclusions:</b> IOS B exhibited superior post space scanning performance compared to IOS A, and its trueness for clinically common post spaces could meet clinical requirements. IOS A has certain requirements for post space opening diameter, post space depth, and adjacent tooth status. For narrow and long post spaces, scanning aid materials can be used to improve the scanning trueness.</p>\",\"PeriodicalId\":23965,\"journal\":{\"name\":\"中华口腔医学杂志\",\"volume\":\"60 10\",\"pages\":\"1144-1151\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华口腔医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112144-20250426-00156\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112144-20250426-00156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨不同岗位参数及扫描辅助材料对两种口腔内扫描仪岗位数字印模准确性的影响,为临床确定适合数字印模技术的岗位条件提供参考。方法:对残冠桩位模型的开口直径、桩位深度和邻牙状态三个变量进行了不同的设置:开口直径分别设置为2.0和2.5 mm;立柱间距深度设置为8.0、10.0、12.0 mm三个层次;邻牙状态分为三个级别[双侧邻牙存在(A),单侧邻牙存在(B),双侧邻牙缺失(C)]。共制备18个模型组。使用三维打印仪器打印了18个样品。结合扫描辅助材料,使用口腔内扫描仪(IOS) A (Trios 5)和B (Primescan connect)对这些后空间模型进行直接体外扫描,每组10个重复(n=10)。扫描数据依次导入逆向工程软件。模型的原始设计数据为真值,进行最佳拟合比较。通过计算平均均方根误差(RMSE)值,评估了两种扫描仪在使用和不使用扫描辅助材料的情况下获得的具有不同形态的后空间数字印象的真实性。结果:在本研究设置的实验条件下,对于IOS A,只能识别出开口直径-桩距深度-邻近牙齿状态组合为(2.0 8.0 ABC、2.5 8.0 ABC、2.5-10.0-ABC)的样品组,RMSE结果在46.5 ~ 365.0 μm之间。添加扫描辅助材料后,RMSE结果在46.0 ~ 185.0 μm范围内,样品组(2.0 ~ 8.0- a, 2.5 ~ 10.0- a)的正确率显著提高100 μm以上,并可识别出另一个样品组(2.5 ~ 12.0- c)。对于IOS B,可识别的样本组包括所有18个样本组,RMSE结果范围为38.8 ~ 106.0 μm。添加扫描辅助材料后,RMSE结果在37.6 ~ 110.2 μm范围内,可识别的样品组保持不变。柱间隙开孔直径、柱间隙深度和邻牙状态均对柱间隙数字印模的准确性有显著影响(PPP>0.05)。结论:IOS B的岗位扫描性能优于IOS A,其对临床常见岗位的真实度可满足临床要求。IOS A对桩位开口直径、桩位深度、邻牙状态有一定的要求。对于狭长的岗位空间,可采用扫描辅助材料,提高扫描正确率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Influence of scanning aid material and post space parameters on the trueness of intraoral scanners for post space: an in vitro study].

Objective: To investigate the effects of different post space parameters and scanning aid material on the trueness of digital impressions of post spaces obtained by two intraoral scanners, thereby providing a reference for clinically determining the conditions under which post spaces are suitable for digital impression technology. Methods: This study varied three variables of post space models of residual crowns: opening diameter, post space depth and adjacent tooth status,with specific settings: opening diameter were set at two levels (2.0 and 2.5 mm);post space depth was set at three levels (8.0, 10.0, and 12.0 mm); and adjacent tooth status were set at three levels [bilateral adjacent teeth present (A), unilateral adjacent tooth present (B), and bilateral adjacent teeth absent (C)]. A total of 18 model groups were prepared. Eighteen samples were printed using a three-dimensional printing instrument. Combined with scanning aid material, direct in vitro scanning of these post space models was performed using intraoral scanners (IOS) A (Trios 5) and B (Primescan connect), with 10 replicates per group (n=10). The scanned data were sequentially imported into reverse engineering software. The original design data of the models served as true values, and best-fit comparisons were performed. By calculating the average root mean square error (RMSE) values, the trueness of digital impressions of post spaces with different morphologies obtained by the two scanners was evaluated, both with and without the use of scanning aid material. Results: Under the experimental conditions set in this study, for IOS A, only the sample groups with opening diameter-post space depth-adjacent tooth status combinations of (2.0 8.0 ABC, 2.5 8.0 ABC, 2.5-10.0-ABC) could be identified, with RMSE results ranging from 46.5 to 365.0 μm. After adding scanning aid materials,RMSE results ranging from 46.0 to 185.0 μm, the trueness of the sample groups (2.0-8.0-A, 2.5-10.0-A) was significantly improved by more than 100 μm, and an additional sample group (2.5-12.0-C) could be identified. For IOS B, the identifiable sample groups included all 18 sample groups, with RMSE results ranging from 38.8 to 106.0 μm. After the addition of scanning aid materials, RMSE results ranging from 37.6 to 110.2 μm, the identifiable sample groups remained unchanged. Post space opening diameter, post space depth, and adjacent tooth status all had significant effects on the trueness of post space digital impressions for both IOS A and IOS B (P<0.05). Scanning aid materials had a significant effect on IOS A (P<0.05) but no significant effect on IOS B (P>0.05). Conclusions: IOS B exhibited superior post space scanning performance compared to IOS A, and its trueness for clinically common post spaces could meet clinical requirements. IOS A has certain requirements for post space opening diameter, post space depth, and adjacent tooth status. For narrow and long post spaces, scanning aid materials can be used to improve the scanning trueness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华口腔医学杂志
中华口腔医学杂志 Medicine-Medicine (all)
CiteScore
0.90
自引率
0.00%
发文量
9692
期刊介绍: Founded in August 1953, Chinese Journal of Stomatology is a monthly academic journal of stomatology published publicly at home and abroad, sponsored by the Chinese Medical Association and co-sponsored by the Chinese Stomatology Association. It mainly reports the leading scientific research results and clinical diagnosis and treatment experience in the field of oral medicine, as well as the basic theoretical research that has a guiding role in oral clinical practice and is closely combined with oral clinical practice. Chinese Journal of Over the years, Stomatology has been published in Medline, Scopus database, Toxicology Abstracts Database, Chemical Abstracts Database, American Cancer database, Russian Abstracts database, China Core Journal of Science and Technology, Peking University Core Journal, CSCD and other more than 20 important journals at home and abroad Physical medicine database and retrieval system included.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信