用于葡萄糖和血液相关分析物检测的入射角调谐、导模共振、基于超表面传感器的数值研究。

IF 3.5 3区 综合性期刊 Q2 CHEMISTRY, ANALYTICAL
Sensors Pub Date : 2025-09-19 DOI:10.3390/s25185852
Zeev Fradkin, Maxim Piscklich, Moshe Zohar, Mark Auslender
{"title":"用于葡萄糖和血液相关分析物检测的入射角调谐、导模共振、基于超表面传感器的数值研究。","authors":"Zeev Fradkin, Maxim Piscklich, Moshe Zohar, Mark Auslender","doi":"10.3390/s25185852","DOIUrl":null,"url":null,"abstract":"<p><p>In optical one-dimensional grating-on-layer planar structures, an optical resonance occurs when the incident light wave becomes phase-matched to a leaky waveguide mode excited in the layer underneath the grating by an appropriate tuning of the grating periodicity. Changing the refractive indices of the grating's constituents, and/or thickness, changes the resonance frequency. In the case of a two-dimensional grating atop such a smooth layer, a similar and also cavity-mode resonance can occur. This idea has straightforward usage in diverse optical sensor applications. In this study, a novel guided-mode resonance sensor design for detecting glucose and hemoglobin in minute concentrations at a wide range of incidence angles is presented. In this design, materials of the grating, such as a polymer and cesium-lead halide with a perovskite crystal structure, are examined, which will allow flexible, low-cost fabrication by soft-lithography/imprint-lithography methods. The sensitivity, figure of merit, and quality factor are reported for one- and two-dimensional grating structures. The simulations performed are based on rigorous coupled-wave analysis. Optical resonance quality factor of ∼5·105 is achieved at oblique incidence for a structure comprising a one-dimensional grating etched in a poly-vinylidene chloride layer atop a silicon nitride waveguide layer on a substrate. Record values of the above-noted characteristics are achieved with a synergetic interplay of the materials, structural dimensions, incidence angle, polarization, and grating geometry.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"25 18","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473734/pdf/","citationCount":"0","resultStr":"{\"title\":\"Numerical Study of Incidence Angle-Tuned, Guided-Mode Resonant, Metasurfaces-Based Sensors for Glucose and Blood-Related Analytes Detection.\",\"authors\":\"Zeev Fradkin, Maxim Piscklich, Moshe Zohar, Mark Auslender\",\"doi\":\"10.3390/s25185852\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In optical one-dimensional grating-on-layer planar structures, an optical resonance occurs when the incident light wave becomes phase-matched to a leaky waveguide mode excited in the layer underneath the grating by an appropriate tuning of the grating periodicity. Changing the refractive indices of the grating's constituents, and/or thickness, changes the resonance frequency. In the case of a two-dimensional grating atop such a smooth layer, a similar and also cavity-mode resonance can occur. This idea has straightforward usage in diverse optical sensor applications. In this study, a novel guided-mode resonance sensor design for detecting glucose and hemoglobin in minute concentrations at a wide range of incidence angles is presented. In this design, materials of the grating, such as a polymer and cesium-lead halide with a perovskite crystal structure, are examined, which will allow flexible, low-cost fabrication by soft-lithography/imprint-lithography methods. The sensitivity, figure of merit, and quality factor are reported for one- and two-dimensional grating structures. The simulations performed are based on rigorous coupled-wave analysis. Optical resonance quality factor of ∼5·105 is achieved at oblique incidence for a structure comprising a one-dimensional grating etched in a poly-vinylidene chloride layer atop a silicon nitride waveguide layer on a substrate. Record values of the above-noted characteristics are achieved with a synergetic interplay of the materials, structural dimensions, incidence angle, polarization, and grating geometry.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":\"25 18\",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473734/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s25185852\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s25185852","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在光学一维层上光栅平面结构中,通过适当调整光栅的周期,当入射光波与光栅下一层激发的漏波导模式相匹配时,就会发生光共振。改变光栅成分的折射率和/或厚度,改变共振频率。在这种光滑层上的二维光栅的情况下,也会发生类似的腔模共振。这个想法在各种光学传感器应用中有直接的用途。在这项研究中,提出了一种新型的导模共振传感器设计,用于在大入射角范围内检测微量浓度的葡萄糖和血红蛋白。在本设计中,光栅的材料,如聚合物和钙钛矿晶体结构的铯-铅卤化物,进行了检查,这将允许柔性,低成本的制造软光刻/压印光刻方法。报道了一维和二维光栅结构的灵敏度、优值和质量因子。所进行的模拟是基于严格的耦合波分析。在斜入射下,光学共振品质因子达到了~ 5·105,该结构包括蚀刻在衬底上氮化硅波导层上的聚偏二氯乙烯层中的一维光栅。上述特性的记录值是通过材料、结构尺寸、入射角、偏振和光栅几何形状的协同相互作用实现的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Numerical Study of Incidence Angle-Tuned, Guided-Mode Resonant, Metasurfaces-Based Sensors for Glucose and Blood-Related Analytes Detection.

Numerical Study of Incidence Angle-Tuned, Guided-Mode Resonant, Metasurfaces-Based Sensors for Glucose and Blood-Related Analytes Detection.

Numerical Study of Incidence Angle-Tuned, Guided-Mode Resonant, Metasurfaces-Based Sensors for Glucose and Blood-Related Analytes Detection.

Numerical Study of Incidence Angle-Tuned, Guided-Mode Resonant, Metasurfaces-Based Sensors for Glucose and Blood-Related Analytes Detection.

In optical one-dimensional grating-on-layer planar structures, an optical resonance occurs when the incident light wave becomes phase-matched to a leaky waveguide mode excited in the layer underneath the grating by an appropriate tuning of the grating periodicity. Changing the refractive indices of the grating's constituents, and/or thickness, changes the resonance frequency. In the case of a two-dimensional grating atop such a smooth layer, a similar and also cavity-mode resonance can occur. This idea has straightforward usage in diverse optical sensor applications. In this study, a novel guided-mode resonance sensor design for detecting glucose and hemoglobin in minute concentrations at a wide range of incidence angles is presented. In this design, materials of the grating, such as a polymer and cesium-lead halide with a perovskite crystal structure, are examined, which will allow flexible, low-cost fabrication by soft-lithography/imprint-lithography methods. The sensitivity, figure of merit, and quality factor are reported for one- and two-dimensional grating structures. The simulations performed are based on rigorous coupled-wave analysis. Optical resonance quality factor of ∼5·105 is achieved at oblique incidence for a structure comprising a one-dimensional grating etched in a poly-vinylidene chloride layer atop a silicon nitride waveguide layer on a substrate. Record values of the above-noted characteristics are achieved with a synergetic interplay of the materials, structural dimensions, incidence angle, polarization, and grating geometry.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors
Sensors 工程技术-电化学
CiteScore
7.30
自引率
12.80%
发文量
8430
审稿时长
1.7 months
期刊介绍: Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信