Inês Sabino, Maria do Carmo Fernandes, Ana Antunes, António Monteny, Bruno Mendes, Carlos Caldeira, Isabel Guimarães, Nidia Grazina, Phillip Probst, Cátia Cepeda, Cláudia Quaresma, Hugo Gamboa, Isabel L Nunes, Ana Teresa Gabriel
{"title":"Ergo4Workers:以用户为中心的应用程序,用于跟踪医疗保健专业人员的姿势和工作量。","authors":"Inês Sabino, Maria do Carmo Fernandes, Ana Antunes, António Monteny, Bruno Mendes, Carlos Caldeira, Isabel Guimarães, Nidia Grazina, Phillip Probst, Cátia Cepeda, Cláudia Quaresma, Hugo Gamboa, Isabel L Nunes, Ana Teresa Gabriel","doi":"10.3390/s25185854","DOIUrl":null,"url":null,"abstract":"<p><p>Healthcare professionals (namely, occupational therapists) face ergonomic risk factors that may lead to work-related musculoskeletal disorders (WRMSD). Ergonomic assessments are crucial to mitigate this occupational issue. Wearable devices are a potential solution for such assessments, providing continuous measurement of biomechanical and physiological parameters. Ergo4workers (E4W) is a mobile application designed to integrate data from independent wearable sensors-motion capture system, surface electromyography, force platform, and smartwatch-to provide an overview of the posture and workload of occupational therapists. It can help identify poor work practices and raise awareness about ergonomic risk factors. This paper describes the development of E4W by following a User-Centred Design (UCD) approach. The initial stage focused on specifying the context of use in collaboration with six occupational therapists. Then the app was implemented using WordPress. Three iterations of the UCD cycle were performed. The usability test of prototype 1 was carried out in a laboratory environment, while the others were tested in a real healthcare work environment. The Cognitive Walkthrough was applied in the usability tests of prototypes 1 and 2. The System Usability Scale evaluated prototype 3. Results evidenced positive feedback, reflecting an easy-to-use and intuitive smartphone app that does not interfere with daily work activities.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":"25 18","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473953/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ergo4Workers: A User-Centred App for Tracking Posture and Workload in Healthcare Professionals.\",\"authors\":\"Inês Sabino, Maria do Carmo Fernandes, Ana Antunes, António Monteny, Bruno Mendes, Carlos Caldeira, Isabel Guimarães, Nidia Grazina, Phillip Probst, Cátia Cepeda, Cláudia Quaresma, Hugo Gamboa, Isabel L Nunes, Ana Teresa Gabriel\",\"doi\":\"10.3390/s25185854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Healthcare professionals (namely, occupational therapists) face ergonomic risk factors that may lead to work-related musculoskeletal disorders (WRMSD). Ergonomic assessments are crucial to mitigate this occupational issue. Wearable devices are a potential solution for such assessments, providing continuous measurement of biomechanical and physiological parameters. Ergo4workers (E4W) is a mobile application designed to integrate data from independent wearable sensors-motion capture system, surface electromyography, force platform, and smartwatch-to provide an overview of the posture and workload of occupational therapists. It can help identify poor work practices and raise awareness about ergonomic risk factors. This paper describes the development of E4W by following a User-Centred Design (UCD) approach. The initial stage focused on specifying the context of use in collaboration with six occupational therapists. Then the app was implemented using WordPress. Three iterations of the UCD cycle were performed. The usability test of prototype 1 was carried out in a laboratory environment, while the others were tested in a real healthcare work environment. The Cognitive Walkthrough was applied in the usability tests of prototypes 1 and 2. The System Usability Scale evaluated prototype 3. Results evidenced positive feedback, reflecting an easy-to-use and intuitive smartphone app that does not interfere with daily work activities.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":\"25 18\",\"pages\":\"\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473953/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s25185854\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s25185854","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Ergo4Workers: A User-Centred App for Tracking Posture and Workload in Healthcare Professionals.
Healthcare professionals (namely, occupational therapists) face ergonomic risk factors that may lead to work-related musculoskeletal disorders (WRMSD). Ergonomic assessments are crucial to mitigate this occupational issue. Wearable devices are a potential solution for such assessments, providing continuous measurement of biomechanical and physiological parameters. Ergo4workers (E4W) is a mobile application designed to integrate data from independent wearable sensors-motion capture system, surface electromyography, force platform, and smartwatch-to provide an overview of the posture and workload of occupational therapists. It can help identify poor work practices and raise awareness about ergonomic risk factors. This paper describes the development of E4W by following a User-Centred Design (UCD) approach. The initial stage focused on specifying the context of use in collaboration with six occupational therapists. Then the app was implemented using WordPress. Three iterations of the UCD cycle were performed. The usability test of prototype 1 was carried out in a laboratory environment, while the others were tested in a real healthcare work environment. The Cognitive Walkthrough was applied in the usability tests of prototypes 1 and 2. The System Usability Scale evaluated prototype 3. Results evidenced positive feedback, reflecting an easy-to-use and intuitive smartphone app that does not interfere with daily work activities.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.