养护和使用温度影响下NSM cfrp增强RC结构的预应力传递:试验验证和分析模型。

IF 4.9 3区 工程技术 Q1 POLYMER SCIENCE
Polymers Pub Date : 2025-09-15 DOI:10.3390/polym17182492
Shuang Gong, Peiqi He, Ruogu Wang, Junjin Li, Jun Liu, Miao Su
{"title":"养护和使用温度影响下NSM cfrp增强RC结构的预应力传递:试验验证和分析模型。","authors":"Shuang Gong, Peiqi He, Ruogu Wang, Junjin Li, Jun Liu, Miao Su","doi":"10.3390/polym17182492","DOIUrl":null,"url":null,"abstract":"<p><p>This study examines the prestress transmission behavior in near-surface-mounted (NSM) carbon fiber-reinforced polymer (CFRP)-strengthened reinforced concrete structures, with particular emphasis on the effects of temperature. Experimental tests were conducted to evaluate the tensile and shear properties of epoxy adhesives under a range of curing temperatures (20-100 °C) and ambient service temperatures (0-80 °C). The results reveal an inverse exponential relationship between curing time and temperature. Notably, adhesive strength declines significantly above 60 °C and the adhesive loses functionality at 80 °C. Building on these findings, an analytical model was developed to predict prestress transfer length, CFRP strain distribution, and interfacial shear stress. The model incorporates effective bond stiffness and a prestress reduction coefficient to account for varying prestress levels (10-50%). Parametric analyses identify the CFRP elastic modulus, cross-sectional geometry, adhesive thickness, and degree of curing as critical factors influencing prestress transmission. The model's predictions were validated against experimental data, demonstrating its reliability. Overall, this work provides a theoretical foundation for optimizing the design of NSM CFRP-strengthened structures under complex thermal conditions.</p>","PeriodicalId":20416,"journal":{"name":"Polymers","volume":"17 18","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473332/pdf/","citationCount":"0","resultStr":"{\"title\":\"Prestress Transfer in NSM CFRP-Strengthened RC Structures Under Curing and Service Temperature Effects: Experimental Validation and Analytical Modeling.\",\"authors\":\"Shuang Gong, Peiqi He, Ruogu Wang, Junjin Li, Jun Liu, Miao Su\",\"doi\":\"10.3390/polym17182492\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study examines the prestress transmission behavior in near-surface-mounted (NSM) carbon fiber-reinforced polymer (CFRP)-strengthened reinforced concrete structures, with particular emphasis on the effects of temperature. Experimental tests were conducted to evaluate the tensile and shear properties of epoxy adhesives under a range of curing temperatures (20-100 °C) and ambient service temperatures (0-80 °C). The results reveal an inverse exponential relationship between curing time and temperature. Notably, adhesive strength declines significantly above 60 °C and the adhesive loses functionality at 80 °C. Building on these findings, an analytical model was developed to predict prestress transfer length, CFRP strain distribution, and interfacial shear stress. The model incorporates effective bond stiffness and a prestress reduction coefficient to account for varying prestress levels (10-50%). Parametric analyses identify the CFRP elastic modulus, cross-sectional geometry, adhesive thickness, and degree of curing as critical factors influencing prestress transmission. The model's predictions were validated against experimental data, demonstrating its reliability. Overall, this work provides a theoretical foundation for optimizing the design of NSM CFRP-strengthened structures under complex thermal conditions.</p>\",\"PeriodicalId\":20416,\"journal\":{\"name\":\"Polymers\",\"volume\":\"17 18\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2025-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473332/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polymers\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/polym17182492\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"POLYMER SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymers","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/polym17182492","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

本研究考察了近表面安装(NSM)碳纤维增强聚合物(CFRP)增强钢筋混凝土结构的预应力传递行为,特别强调温度的影响。在固化温度(20-100℃)和环境使用温度(0-80℃)范围内,对环氧胶粘剂的拉伸和剪切性能进行了试验研究。结果表明,固化时间与温度呈反指数关系。值得注意的是,粘合剂强度在60°C以上明显下降,粘合剂在80°C时失去功能。基于这些发现,建立了一个分析模型来预测预应力传递长度、CFRP应变分布和界面剪应力。该模型结合了有效粘结刚度和预应力减小系数来考虑不同的预应力水平(10-50%)。参数分析表明CFRP弹性模量、截面几何形状、胶粘剂厚度和固化程度是影响预应力传递的关键因素。通过实验数据验证了模型的预测结果,证明了模型的可靠性。本研究为复杂热条件下NSM cfrp加固结构的优化设计提供了理论基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prestress Transfer in NSM CFRP-Strengthened RC Structures Under Curing and Service Temperature Effects: Experimental Validation and Analytical Modeling.

This study examines the prestress transmission behavior in near-surface-mounted (NSM) carbon fiber-reinforced polymer (CFRP)-strengthened reinforced concrete structures, with particular emphasis on the effects of temperature. Experimental tests were conducted to evaluate the tensile and shear properties of epoxy adhesives under a range of curing temperatures (20-100 °C) and ambient service temperatures (0-80 °C). The results reveal an inverse exponential relationship between curing time and temperature. Notably, adhesive strength declines significantly above 60 °C and the adhesive loses functionality at 80 °C. Building on these findings, an analytical model was developed to predict prestress transfer length, CFRP strain distribution, and interfacial shear stress. The model incorporates effective bond stiffness and a prestress reduction coefficient to account for varying prestress levels (10-50%). Parametric analyses identify the CFRP elastic modulus, cross-sectional geometry, adhesive thickness, and degree of curing as critical factors influencing prestress transmission. The model's predictions were validated against experimental data, demonstrating its reliability. Overall, this work provides a theoretical foundation for optimizing the design of NSM CFRP-strengthened structures under complex thermal conditions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polymers
Polymers POLYMER SCIENCE-
CiteScore
8.00
自引率
16.00%
发文量
4697
审稿时长
1.3 months
期刊介绍: Polymers (ISSN 2073-4360) is an international, open access journal of polymer science. It publishes research papers, short communications and review papers. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Polymers provides an interdisciplinary forum for publishing papers which advance the fields of (i) polymerization methods, (ii) theory, simulation, and modeling, (iii) understanding of new physical phenomena, (iv) advances in characterization techniques, and (v) harnessing of self-assembly and biological strategies for producing complex multifunctional structures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信