一种新型的基于虚拟现实的斜视偏斜角测量系统:前瞻性研究。

IF 3.3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Jhih-Yi Lu, Yin-Cheng Liu, Jui-Bang Lu, Ming-Han Tsai, Wen-Ling Liao, I-Ming Wang, Hui-Ju Lin, Yu-Te Huang
{"title":"一种新型的基于虚拟现实的斜视偏斜角测量系统:前瞻性研究。","authors":"Jhih-Yi Lu, Yin-Cheng Liu, Jui-Bang Lu, Ming-Han Tsai, Wen-Ling Liao, I-Ming Wang, Hui-Ju Lin, Yu-Te Huang","doi":"10.3390/diagnostics15182402","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives</b>: To develop a new Virtual Reality (VR) system software for measuring ocular deviation in strabismus patients. <b>Methods</b>: This prospective study included subjects with basic-type exotropia (XT) and non-refractive accommodative esotropia (ET). Ocular deviation was measured using the alternate prism cover test (APCT) and two VR-based methods: target offset (TO) and a newly developed camera rotation (CR) method. <b>Results</b>: A total of 28 subjects were recruited (5 cases were excluded for preliminary testing and 5 for not meeting inclusion criteria). Among the 18 included patients, 10 (66.7%) had XT and 5 (33.3%) had ET. The median age was 21.5 years (IQR 17 to 25). The mean age was 22.3 years (range: 9-46), with 5 (27.8%) having manifest strabismus and 12 (61.1%) measured while wearing glasses. VR-based methods (TO and CR) showed comparable results to APCT for deviation angle measurements (<i>p</i> = 0.604). Subgroup analysis showed no significant differences in ET patients (all <i>p</i> > 0.05). In XT patients, both TO and CR underestimated deviation angles compared to APCT (<i>p</i> = 0.008 and <i>p</i> = 0.001, respectively), but no significant difference was observed between the two methods (<i>p</i> = 0.811). Linear regression showed CR had a stronger correlation with APCT than TO (R<sup>2</sup> = 0.934 vs. 0.874). <b>Conclusions</b>: This newly developed VR system software, incorporating the CR method, provides a reliable approach for measuring ocular deviation. By shifting the entire visual scene rather than just the target, it lays a strong foundation for immersive diagnostic and therapeutic VR applications.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 18","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12468358/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Novel Virtual Reality-Based System for Measuring Deviation Angle in Strabismus: A Prospective Study.\",\"authors\":\"Jhih-Yi Lu, Yin-Cheng Liu, Jui-Bang Lu, Ming-Han Tsai, Wen-Ling Liao, I-Ming Wang, Hui-Ju Lin, Yu-Te Huang\",\"doi\":\"10.3390/diagnostics15182402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background/Objectives</b>: To develop a new Virtual Reality (VR) system software for measuring ocular deviation in strabismus patients. <b>Methods</b>: This prospective study included subjects with basic-type exotropia (XT) and non-refractive accommodative esotropia (ET). Ocular deviation was measured using the alternate prism cover test (APCT) and two VR-based methods: target offset (TO) and a newly developed camera rotation (CR) method. <b>Results</b>: A total of 28 subjects were recruited (5 cases were excluded for preliminary testing and 5 for not meeting inclusion criteria). Among the 18 included patients, 10 (66.7%) had XT and 5 (33.3%) had ET. The median age was 21.5 years (IQR 17 to 25). The mean age was 22.3 years (range: 9-46), with 5 (27.8%) having manifest strabismus and 12 (61.1%) measured while wearing glasses. VR-based methods (TO and CR) showed comparable results to APCT for deviation angle measurements (<i>p</i> = 0.604). Subgroup analysis showed no significant differences in ET patients (all <i>p</i> > 0.05). In XT patients, both TO and CR underestimated deviation angles compared to APCT (<i>p</i> = 0.008 and <i>p</i> = 0.001, respectively), but no significant difference was observed between the two methods (<i>p</i> = 0.811). Linear regression showed CR had a stronger correlation with APCT than TO (R<sup>2</sup> = 0.934 vs. 0.874). <b>Conclusions</b>: This newly developed VR system software, incorporating the CR method, provides a reliable approach for measuring ocular deviation. By shifting the entire visual scene rather than just the target, it lays a strong foundation for immersive diagnostic and therapeutic VR applications.</p>\",\"PeriodicalId\":11225,\"journal\":{\"name\":\"Diagnostics\",\"volume\":\"15 18\",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12468358/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/diagnostics15182402\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15182402","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:开发一种用于斜视患者眼偏测量的虚拟现实(VR)系统软件。方法:本前瞻性研究纳入基础型外斜视(XT)和非屈光性调节性内斜视(ET)患者。眼偏测量采用交替棱镜盖测试(APCT)和两种基于vr的方法:目标偏移(TO)和新开发的相机旋转(CR)法。结果:共纳入受试者28例(5例因初步检验被排除,5例因不符合纳入标准被排除)。纳入的18例患者中,10例(66.7%)有XT, 5例(33.3%)有ET。中位年龄为21.5岁(IQR 17 ~ 25)。平均年龄22.3岁(范围:9-46岁),其中5例(27.8%)有明显斜视,12例(61.1%)戴眼镜。基于vr的方法(TO和CR)的偏差角测量结果与APCT相当(p = 0.604)。亚组分析显示ET患者无显著性差异(p < 0.05)。在XT患者中,与APCT相比,TO和CR均低估了偏差角度(p = 0.008和p = 0.001),但两种方法之间无显著差异(p = 0.811)。线性回归显示,CR与APCT的相关性强于TO (R2 = 0.934 vs. 0.874)。结论:新开发的VR系统软件,结合CR方法,为测量眼偏度提供了可靠的方法。通过改变整个视觉场景而不仅仅是目标,它为沉浸式诊断和治疗VR应用奠定了坚实的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Novel Virtual Reality-Based System for Measuring Deviation Angle in Strabismus: A Prospective Study.

Background/Objectives: To develop a new Virtual Reality (VR) system software for measuring ocular deviation in strabismus patients. Methods: This prospective study included subjects with basic-type exotropia (XT) and non-refractive accommodative esotropia (ET). Ocular deviation was measured using the alternate prism cover test (APCT) and two VR-based methods: target offset (TO) and a newly developed camera rotation (CR) method. Results: A total of 28 subjects were recruited (5 cases were excluded for preliminary testing and 5 for not meeting inclusion criteria). Among the 18 included patients, 10 (66.7%) had XT and 5 (33.3%) had ET. The median age was 21.5 years (IQR 17 to 25). The mean age was 22.3 years (range: 9-46), with 5 (27.8%) having manifest strabismus and 12 (61.1%) measured while wearing glasses. VR-based methods (TO and CR) showed comparable results to APCT for deviation angle measurements (p = 0.604). Subgroup analysis showed no significant differences in ET patients (all p > 0.05). In XT patients, both TO and CR underestimated deviation angles compared to APCT (p = 0.008 and p = 0.001, respectively), but no significant difference was observed between the two methods (p = 0.811). Linear regression showed CR had a stronger correlation with APCT than TO (R2 = 0.934 vs. 0.874). Conclusions: This newly developed VR system software, incorporating the CR method, provides a reliable approach for measuring ocular deviation. By shifting the entire visual scene rather than just the target, it lays a strong foundation for immersive diagnostic and therapeutic VR applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信