{"title":"超声壳体深度测量的多响应优化","authors":"Mahdi Bayat-Kazazi, Farhang Honarvar, Alireza Bahadory","doi":"10.1007/s10921-025-01207-8","DOIUrl":null,"url":null,"abstract":"<div><p>This paper presents a methodology for optimizing the parameters of the immersion ultrasonic backscattering technique used in measuring the case depth of induction-hardened parts. The accuracy of an immersion ultrasonic backscattering technique is governed by two major parameters: the probe angle and probe distance from the part surface. The required equations are derived to calculate the probe distance based on the focal length of the probe. A design of experiments (DOE) process is also performed by conducting 81 tests on three surface-hardened steel shafts, to identify the significant factors affecting the measurement results. The findings demonstrate the effectiveness of the probe angle, probe distance and their interaction in the backscattering technique. The desirability function approach is then used to optimize the multi-response results of case depth measurements. The optimal settings for this specific case are determined as a probe angle of 16° and a probe distance of 10 mm, resulting in a desirability function value of 0.90. The methodology introduced in this paper can be applied to other backscattering applications, providing optimal configurations for ultrasonic testing, and improving measurement accuracy.</p></div>","PeriodicalId":655,"journal":{"name":"Journal of Nondestructive Evaluation","volume":"44 3","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-response Optimization of Ultrasonic Case Depth Measurement\",\"authors\":\"Mahdi Bayat-Kazazi, Farhang Honarvar, Alireza Bahadory\",\"doi\":\"10.1007/s10921-025-01207-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper presents a methodology for optimizing the parameters of the immersion ultrasonic backscattering technique used in measuring the case depth of induction-hardened parts. The accuracy of an immersion ultrasonic backscattering technique is governed by two major parameters: the probe angle and probe distance from the part surface. The required equations are derived to calculate the probe distance based on the focal length of the probe. A design of experiments (DOE) process is also performed by conducting 81 tests on three surface-hardened steel shafts, to identify the significant factors affecting the measurement results. The findings demonstrate the effectiveness of the probe angle, probe distance and their interaction in the backscattering technique. The desirability function approach is then used to optimize the multi-response results of case depth measurements. The optimal settings for this specific case are determined as a probe angle of 16° and a probe distance of 10 mm, resulting in a desirability function value of 0.90. The methodology introduced in this paper can be applied to other backscattering applications, providing optimal configurations for ultrasonic testing, and improving measurement accuracy.</p></div>\",\"PeriodicalId\":655,\"journal\":{\"name\":\"Journal of Nondestructive Evaluation\",\"volume\":\"44 3\",\"pages\":\"\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2025-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nondestructive Evaluation\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10921-025-01207-8\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nondestructive Evaluation","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s10921-025-01207-8","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
Multi-response Optimization of Ultrasonic Case Depth Measurement
This paper presents a methodology for optimizing the parameters of the immersion ultrasonic backscattering technique used in measuring the case depth of induction-hardened parts. The accuracy of an immersion ultrasonic backscattering technique is governed by two major parameters: the probe angle and probe distance from the part surface. The required equations are derived to calculate the probe distance based on the focal length of the probe. A design of experiments (DOE) process is also performed by conducting 81 tests on three surface-hardened steel shafts, to identify the significant factors affecting the measurement results. The findings demonstrate the effectiveness of the probe angle, probe distance and their interaction in the backscattering technique. The desirability function approach is then used to optimize the multi-response results of case depth measurements. The optimal settings for this specific case are determined as a probe angle of 16° and a probe distance of 10 mm, resulting in a desirability function value of 0.90. The methodology introduced in this paper can be applied to other backscattering applications, providing optimal configurations for ultrasonic testing, and improving measurement accuracy.
期刊介绍:
Journal of Nondestructive Evaluation provides a forum for the broad range of scientific and engineering activities involved in developing a quantitative nondestructive evaluation (NDE) capability. This interdisciplinary journal publishes papers on the development of new equipment, analyses, and approaches to nondestructive measurements.