Charles Evrard, Julien Blaess, Thibaut Goetsch, Etienne Fellous, Francois Pietra, Alain Meyer, Margherita Giannini, Bernard Geny
{"title":"使用双能x射线吸收仪(DEXA)测量职业足球运动员的阑尾瘦质量指数:一种改进操作人员间重复性和分析骨盆-粗隆肌的新方法的初步研究。","authors":"Charles Evrard, Julien Blaess, Thibaut Goetsch, Etienne Fellous, Francois Pietra, Alain Meyer, Margherita Giannini, Bernard Geny","doi":"10.3390/sports13090285","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Body composition assessment is important in professional football as a measure of overall adaptation of the athlete to the training demand and calorie intake. However, it is operator-dependent, relying on subject positioning and the focus angle of the X-rays. In addition, the usual appendicular lean mass index (ALMI) does not include the pelvitrochanteric muscles, which are often implicated in athlete injuries. <b>Methods:</b> Three independent operators compared the reproducibility of dual-energy X-ray absorptiometry (DEXA) including pelvi-trochanteric muscle mass in twenty professional football players, using the standard and a new method. <b>Results:</b> Mean age, weight, and height of the footballers were 25.9 ± 4.9 years, 79.4 ± 9.4 kg, and 1.83 ± 0.09 m. Using the standard method, the ALMI was 9.28 ± 0.62, 9.20 ± 0.65, and 9.13 ± 0.64 kg/m<sup>2</sup> for the first, second and third operator, respectively. When including the pelvi-trochanteric muscles, the ALMI values were 11.90 ± 0.66, 11.84 ± 0.63, and 11.83 ± 0.65 kg/m<sup>2</sup> for the three operators. The difference between the two methods was significant (<i>p</i> < 0.001). The mean inter-operator difference was similar regardless of the method used (0.099 ± 0.06 kg/m<sup>2</sup>). The intraclass correlation coefficients (ICC) (A,1) were 0.949 [0.881; 0.979] for the standard method and 0.977 [0.951; 0.990] for the new method. The ICC (C,1) was 0.960 [0.918; 0.983] for the standard method and 0.979 [0.957; 0.991] for the new method. <b>Conclusions:</b> Thus, both new and conventional methods showed excellent reproducibility. However, reproducibility and inter-operator variability were better with the adjustment of the new scan lines. Moreover, the inclusion of a larger gluteal and adductors muscle mass was easy to achieve, providing additional information that could potentially be useful for early diagnosis and/or prevention of future muscular injuries in elite athletes.</p>","PeriodicalId":53303,"journal":{"name":"Sports","volume":"13 9","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473212/pdf/","citationCount":"0","resultStr":"{\"title\":\"Appendicular Lean Mass Index Using Dual-Energy X-Ray Absorptiometry (DEXA) in Professional Football: A Pilot Study of a New Method for Improved Inter-Operator Reproducibility and Analysis of Pelvi-Trochanteric Muscles.\",\"authors\":\"Charles Evrard, Julien Blaess, Thibaut Goetsch, Etienne Fellous, Francois Pietra, Alain Meyer, Margherita Giannini, Bernard Geny\",\"doi\":\"10.3390/sports13090285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Body composition assessment is important in professional football as a measure of overall adaptation of the athlete to the training demand and calorie intake. However, it is operator-dependent, relying on subject positioning and the focus angle of the X-rays. In addition, the usual appendicular lean mass index (ALMI) does not include the pelvitrochanteric muscles, which are often implicated in athlete injuries. <b>Methods:</b> Three independent operators compared the reproducibility of dual-energy X-ray absorptiometry (DEXA) including pelvi-trochanteric muscle mass in twenty professional football players, using the standard and a new method. <b>Results:</b> Mean age, weight, and height of the footballers were 25.9 ± 4.9 years, 79.4 ± 9.4 kg, and 1.83 ± 0.09 m. Using the standard method, the ALMI was 9.28 ± 0.62, 9.20 ± 0.65, and 9.13 ± 0.64 kg/m<sup>2</sup> for the first, second and third operator, respectively. When including the pelvi-trochanteric muscles, the ALMI values were 11.90 ± 0.66, 11.84 ± 0.63, and 11.83 ± 0.65 kg/m<sup>2</sup> for the three operators. The difference between the two methods was significant (<i>p</i> < 0.001). The mean inter-operator difference was similar regardless of the method used (0.099 ± 0.06 kg/m<sup>2</sup>). The intraclass correlation coefficients (ICC) (A,1) were 0.949 [0.881; 0.979] for the standard method and 0.977 [0.951; 0.990] for the new method. The ICC (C,1) was 0.960 [0.918; 0.983] for the standard method and 0.979 [0.957; 0.991] for the new method. <b>Conclusions:</b> Thus, both new and conventional methods showed excellent reproducibility. However, reproducibility and inter-operator variability were better with the adjustment of the new scan lines. Moreover, the inclusion of a larger gluteal and adductors muscle mass was easy to achieve, providing additional information that could potentially be useful for early diagnosis and/or prevention of future muscular injuries in elite athletes.</p>\",\"PeriodicalId\":53303,\"journal\":{\"name\":\"Sports\",\"volume\":\"13 9\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473212/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/sports13090285\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SPORT SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/sports13090285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
Appendicular Lean Mass Index Using Dual-Energy X-Ray Absorptiometry (DEXA) in Professional Football: A Pilot Study of a New Method for Improved Inter-Operator Reproducibility and Analysis of Pelvi-Trochanteric Muscles.
Background: Body composition assessment is important in professional football as a measure of overall adaptation of the athlete to the training demand and calorie intake. However, it is operator-dependent, relying on subject positioning and the focus angle of the X-rays. In addition, the usual appendicular lean mass index (ALMI) does not include the pelvitrochanteric muscles, which are often implicated in athlete injuries. Methods: Three independent operators compared the reproducibility of dual-energy X-ray absorptiometry (DEXA) including pelvi-trochanteric muscle mass in twenty professional football players, using the standard and a new method. Results: Mean age, weight, and height of the footballers were 25.9 ± 4.9 years, 79.4 ± 9.4 kg, and 1.83 ± 0.09 m. Using the standard method, the ALMI was 9.28 ± 0.62, 9.20 ± 0.65, and 9.13 ± 0.64 kg/m2 for the first, second and third operator, respectively. When including the pelvi-trochanteric muscles, the ALMI values were 11.90 ± 0.66, 11.84 ± 0.63, and 11.83 ± 0.65 kg/m2 for the three operators. The difference between the two methods was significant (p < 0.001). The mean inter-operator difference was similar regardless of the method used (0.099 ± 0.06 kg/m2). The intraclass correlation coefficients (ICC) (A,1) were 0.949 [0.881; 0.979] for the standard method and 0.977 [0.951; 0.990] for the new method. The ICC (C,1) was 0.960 [0.918; 0.983] for the standard method and 0.979 [0.957; 0.991] for the new method. Conclusions: Thus, both new and conventional methods showed excellent reproducibility. However, reproducibility and inter-operator variability were better with the adjustment of the new scan lines. Moreover, the inclusion of a larger gluteal and adductors muscle mass was easy to achieve, providing additional information that could potentially be useful for early diagnosis and/or prevention of future muscular injuries in elite athletes.