Vidushi Saxena, Salil Pawah, Manisha Gulati, Neha Jain, Sakshi Kataria, Pankaj Dhawan
{"title":"两种常用印模方法在全牙无牙患者多颗夹板种植体中的比较-一项体外研究。","authors":"Vidushi Saxena, Salil Pawah, Manisha Gulati, Neha Jain, Sakshi Kataria, Pankaj Dhawan","doi":"10.4103/ijdr.ijdr_438_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate impressions of implants are required for transferring position of implants to master cast so no additional stresses are placed on the implants through final restorations. Various impression materials, types of trays and their combinations have been described for the clinicians to choose from.</p><p><strong>Aim: </strong>This study aimed to compare the accuracy of the commonly employed impression technique to another recommended technique, for multiple splinted implants.</p><p><strong>Materials and methods: </strong>This in vitro , comparative, experimental study consisted of 10 master casts prepared by 10 secondary impressions which were made by 2 different impression techniques i.e., polyvinyl siloxane with open stock tray and polyether with an open custom tray, which are routinely used by clinicians in daily practice. The inter-implant distance was measured by the coordinate measuring machine. Data was collected and analyzed statistically to obtain the result.</p><p><strong>Results: </strong>The values of coordinates that were significant (1 and 2, 3 and 4, 1 and 4, and 2 and 4) were selected to measure the accuracy of the material used for the impression and tray type employed. The accuracy of the impressions was analyzed by using Scheffé's method. Mostly non-significant differences were observed between the centroids using the two techniques.</p><p><strong>Conclusion: </strong>The results suggested that both polyether and polyvinyl siloxane impression materials have nearly equally precise dimensional accuracy and are comparable to each other. Although not statistically significant, polyvinyl siloxane showed slightly higher accuracy than polyether. Both the trays used with their respective impression materials provided clinically acceptable results and hence may be used interchangeably.</p>","PeriodicalId":13311,"journal":{"name":"Indian Journal of Dental Research","volume":" ","pages":"192-196"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Comparison of Two Commonly Employed Impression Methods for Multiple Splinted Implants in Completely Edentulous Patients - An In vitro Study.\",\"authors\":\"Vidushi Saxena, Salil Pawah, Manisha Gulati, Neha Jain, Sakshi Kataria, Pankaj Dhawan\",\"doi\":\"10.4103/ijdr.ijdr_438_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Accurate impressions of implants are required for transferring position of implants to master cast so no additional stresses are placed on the implants through final restorations. Various impression materials, types of trays and their combinations have been described for the clinicians to choose from.</p><p><strong>Aim: </strong>This study aimed to compare the accuracy of the commonly employed impression technique to another recommended technique, for multiple splinted implants.</p><p><strong>Materials and methods: </strong>This in vitro , comparative, experimental study consisted of 10 master casts prepared by 10 secondary impressions which were made by 2 different impression techniques i.e., polyvinyl siloxane with open stock tray and polyether with an open custom tray, which are routinely used by clinicians in daily practice. The inter-implant distance was measured by the coordinate measuring machine. Data was collected and analyzed statistically to obtain the result.</p><p><strong>Results: </strong>The values of coordinates that were significant (1 and 2, 3 and 4, 1 and 4, and 2 and 4) were selected to measure the accuracy of the material used for the impression and tray type employed. The accuracy of the impressions was analyzed by using Scheffé's method. Mostly non-significant differences were observed between the centroids using the two techniques.</p><p><strong>Conclusion: </strong>The results suggested that both polyether and polyvinyl siloxane impression materials have nearly equally precise dimensional accuracy and are comparable to each other. Although not statistically significant, polyvinyl siloxane showed slightly higher accuracy than polyether. Both the trays used with their respective impression materials provided clinically acceptable results and hence may be used interchangeably.</p>\",\"PeriodicalId\":13311,\"journal\":{\"name\":\"Indian Journal of Dental Research\",\"volume\":\" \",\"pages\":\"192-196\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ijdr.ijdr_438_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/9/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijdr.ijdr_438_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:为了将种植体的位置转移到主铸体上,需要准确的种植体印模,这样在最终修复过程中不会对种植体施加额外的应力。各种印模材料,类型的托盘和他们的组合已经描述,供临床医生选择。目的:本研究的目的是比较常用的印模技术和另一种推荐的技术的准确性,用于多个夹板种植体。材料和方法:这项体外比较实验研究包括10个主模,由10个二级压模制备,由2种不同的压模技术制成,即聚氯乙烯硅氧烷与开放式库存托盘和聚醚与开放式定制托盘,临床医生在日常实践中经常使用。种植体间距离用三坐标测量机测量。收集数据并进行统计分析,得出结果。结果:选择具有显著意义的坐标值(1和2、3和4、1和4、2和4)来测量所采用的印模和托盘类型所用材料的准确性。用scheff方法分析了印痕的精度。使用两种技术观察到的质心之间的差异大多不显著。结论:聚醚和聚硅氧烷两种压模材料的尺寸精度几乎相同,具有可比性。虽然没有统计学上的显著性,但聚乙烯醇硅氧烷的准确度略高于聚醚。两种托盘及其各自的印模材料提供临床可接受的结果,因此可以互换使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Comparison of Two Commonly Employed Impression Methods for Multiple Splinted Implants in Completely Edentulous Patients - An In vitro Study.

Background: Accurate impressions of implants are required for transferring position of implants to master cast so no additional stresses are placed on the implants through final restorations. Various impression materials, types of trays and their combinations have been described for the clinicians to choose from.

Aim: This study aimed to compare the accuracy of the commonly employed impression technique to another recommended technique, for multiple splinted implants.

Materials and methods: This in vitro , comparative, experimental study consisted of 10 master casts prepared by 10 secondary impressions which were made by 2 different impression techniques i.e., polyvinyl siloxane with open stock tray and polyether with an open custom tray, which are routinely used by clinicians in daily practice. The inter-implant distance was measured by the coordinate measuring machine. Data was collected and analyzed statistically to obtain the result.

Results: The values of coordinates that were significant (1 and 2, 3 and 4, 1 and 4, and 2 and 4) were selected to measure the accuracy of the material used for the impression and tray type employed. The accuracy of the impressions was analyzed by using Scheffé's method. Mostly non-significant differences were observed between the centroids using the two techniques.

Conclusion: The results suggested that both polyether and polyvinyl siloxane impression materials have nearly equally precise dimensional accuracy and are comparable to each other. Although not statistically significant, polyvinyl siloxane showed slightly higher accuracy than polyether. Both the trays used with their respective impression materials provided clinically acceptable results and hence may be used interchangeably.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Journal of Dental Research
Indian Journal of Dental Research Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
80
审稿时长
38 weeks
期刊介绍: Indian Journal of Dental Research (IJDR) is the official publication of the Indian Society for Dental Research (ISDR), India section of the International Association for Dental Research (IADR), published quarterly. IJDR publishes scientific papers on well designed and controlled original research involving orodental sciences. Papers may also include reports on unusual and interesting case presentations and invited review papers on significant topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信