SOCIA III矫治器对假III类错牙合患者骨骼和牙槽骨的影响。

IF 3.1 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Mauro Lorusso, Giovanna Jie Wang, Michele Tepedino, Angela Pia Cazzolla, Fariba Esperouz, Lucio Lo Russo, Domenico Ciavarella
{"title":"SOCIA III矫治器对假III类错牙合患者骨骼和牙槽骨的影响。","authors":"Mauro Lorusso, Giovanna Jie Wang, Michele Tepedino, Angela Pia Cazzolla, Fariba Esperouz, Lucio Lo Russo, Domenico Ciavarella","doi":"10.3390/dj13090427","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> This study aimed to assess the dentoskeletal and postural modifications induced by treatment with the Swallowing Occlusal Contact Intercept Appliance (SOCIA III) in patients with pseudo-Class III malocclusion. The main hypothesis was that treatment with the SOCIA appliance induces significant skeletal and dentoalveolar changes in growing patients with pseudo-Class III malocclusion. <b>Methods:</b> Fifty-two pseudo-Class III malocclusion patients with a mean age of 8.5 were analyzed and compared with fifty-two untreated patients. Cephalometric evaluations were carried out at baseline (T0) and at the end of treatment. The cephalometric analysis comprised sagittal measurements (SNA, ANB, WITS, CB, ACB), dental variables (UI-PP, LI-MP, OVERJET, OVERBITE), and postural parameters (SNBa and cranio-cervical angle of the maxilla). Within-group comparisons at baseline (T0) and post-treatment (T1) were performed using the paired <i>t</i>-test or the Wilcoxon signed-rank test. Inter-group comparisons were based on the differences in variables between the two time points (ΔT1-T0), using the independent samples <i>t</i>-test or the Mann-Whitney U test. <b>Results:</b> At the end of treatment with the SOCIA appliance, significant improvements were observed in the ANB angle (0.61° to 2.06°, <i>p</i> = 0.001), SNA (81.56° to 83.26°, <i>p</i> = 0.006), WITS appraisal (-0.75 mm to 1.24 mm, <i>p</i> = 0.001), ACB angle (9.35 mm to 11.45 mm, <i>p</i> = 0.05), CB (64.78 mm to 65.51 mm, <i>p</i> = 0.03), and SNBa angle (127.57° to 129.14°, <i>p</i> = 0.01), as well as in overjet (0.62 mm to 3.60 mm, <i>p</i> = 0.001) and overbite (0.29 mm to 1.82 mm, <i>p</i> = 0.001). <b>Conclusions:</b> The SOCIA III appliance is effective in correcting pseudo-Class III malocclusion in growing patients by improving skeletal and dentoalveolar relationships.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":"13 9","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12468626/pdf/","citationCount":"0","resultStr":"{\"title\":\"Skeletal and Dentoalveolar Effects of the SOCIA III Appliance in Patients with Pseudo-Class III Malocclusion.\",\"authors\":\"Mauro Lorusso, Giovanna Jie Wang, Michele Tepedino, Angela Pia Cazzolla, Fariba Esperouz, Lucio Lo Russo, Domenico Ciavarella\",\"doi\":\"10.3390/dj13090427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> This study aimed to assess the dentoskeletal and postural modifications induced by treatment with the Swallowing Occlusal Contact Intercept Appliance (SOCIA III) in patients with pseudo-Class III malocclusion. The main hypothesis was that treatment with the SOCIA appliance induces significant skeletal and dentoalveolar changes in growing patients with pseudo-Class III malocclusion. <b>Methods:</b> Fifty-two pseudo-Class III malocclusion patients with a mean age of 8.5 were analyzed and compared with fifty-two untreated patients. Cephalometric evaluations were carried out at baseline (T0) and at the end of treatment. The cephalometric analysis comprised sagittal measurements (SNA, ANB, WITS, CB, ACB), dental variables (UI-PP, LI-MP, OVERJET, OVERBITE), and postural parameters (SNBa and cranio-cervical angle of the maxilla). Within-group comparisons at baseline (T0) and post-treatment (T1) were performed using the paired <i>t</i>-test or the Wilcoxon signed-rank test. Inter-group comparisons were based on the differences in variables between the two time points (ΔT1-T0), using the independent samples <i>t</i>-test or the Mann-Whitney U test. <b>Results:</b> At the end of treatment with the SOCIA appliance, significant improvements were observed in the ANB angle (0.61° to 2.06°, <i>p</i> = 0.001), SNA (81.56° to 83.26°, <i>p</i> = 0.006), WITS appraisal (-0.75 mm to 1.24 mm, <i>p</i> = 0.001), ACB angle (9.35 mm to 11.45 mm, <i>p</i> = 0.05), CB (64.78 mm to 65.51 mm, <i>p</i> = 0.03), and SNBa angle (127.57° to 129.14°, <i>p</i> = 0.01), as well as in overjet (0.62 mm to 3.60 mm, <i>p</i> = 0.001) and overbite (0.29 mm to 1.82 mm, <i>p</i> = 0.001). <b>Conclusions:</b> The SOCIA III appliance is effective in correcting pseudo-Class III malocclusion in growing patients by improving skeletal and dentoalveolar relationships.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":\"13 9\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12468626/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj13090427\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj13090427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估吞咽接触拦截器(SOCIA III)治疗假性III类错牙合患者的牙骨骼和体位改变。主要的假设是,使用SOCIA矫治器治疗会导致假性III类错牙合患者的骨骼和牙槽骨发生明显的变化。方法:对52例平均年龄8.5岁的假性III类错颌患者进行分析,并与52例未经治疗的患者进行比较。在基线(T0)和治疗结束时进行头部测量评估。头侧测量分析包括矢状测量(SNA、ANB、WITS、CB、ACB)、牙齿变量(UI-PP、LI-MP、OVERJET、OVERBITE)和体位参数(SNBa和上颌骨颅颈角)。基线(T0)和治疗后(T1)的组内比较采用配对t检验或Wilcoxon符号秩检验。组间比较基于两个时间点之间变量的差异(ΔT1-T0),使用独立样本t检验或Mann-Whitney U检验。结果:治疗结束后,副部设备,显著改善被观察到在美角(0.61°到2.06°,p = 0.001),系统网络体系结构(SNA)(81.56°到83.26°,p = 0.006),智慧评价(-0.75毫米到1.24毫米,p = 0.001), ACB角(9.35毫米到11.45毫米,p = 0.05), CB(64.78毫米到65.51毫米,p = 0.03),和SNBa角(127.57°到129.14°,p = 0.01),以及希望(0.62毫米到3.60毫米,p = 0.001)和覆咬合(0.29毫米到1.82毫米,p = 0.001)。结论:SOCIA III矫治器通过改善骨骼和牙槽牙的关系,可以有效矫正生长患者的假性III类错牙合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Skeletal and Dentoalveolar Effects of the SOCIA III Appliance in Patients with Pseudo-Class III Malocclusion.

Objective: This study aimed to assess the dentoskeletal and postural modifications induced by treatment with the Swallowing Occlusal Contact Intercept Appliance (SOCIA III) in patients with pseudo-Class III malocclusion. The main hypothesis was that treatment with the SOCIA appliance induces significant skeletal and dentoalveolar changes in growing patients with pseudo-Class III malocclusion. Methods: Fifty-two pseudo-Class III malocclusion patients with a mean age of 8.5 were analyzed and compared with fifty-two untreated patients. Cephalometric evaluations were carried out at baseline (T0) and at the end of treatment. The cephalometric analysis comprised sagittal measurements (SNA, ANB, WITS, CB, ACB), dental variables (UI-PP, LI-MP, OVERJET, OVERBITE), and postural parameters (SNBa and cranio-cervical angle of the maxilla). Within-group comparisons at baseline (T0) and post-treatment (T1) were performed using the paired t-test or the Wilcoxon signed-rank test. Inter-group comparisons were based on the differences in variables between the two time points (ΔT1-T0), using the independent samples t-test or the Mann-Whitney U test. Results: At the end of treatment with the SOCIA appliance, significant improvements were observed in the ANB angle (0.61° to 2.06°, p = 0.001), SNA (81.56° to 83.26°, p = 0.006), WITS appraisal (-0.75 mm to 1.24 mm, p = 0.001), ACB angle (9.35 mm to 11.45 mm, p = 0.05), CB (64.78 mm to 65.51 mm, p = 0.03), and SNBa angle (127.57° to 129.14°, p = 0.01), as well as in overjet (0.62 mm to 3.60 mm, p = 0.001) and overbite (0.29 mm to 1.82 mm, p = 0.001). Conclusions: The SOCIA III appliance is effective in correcting pseudo-Class III malocclusion in growing patients by improving skeletal and dentoalveolar relationships.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信