{"title":"实时连续记录二次电子脉冲的激活型脉冲中子辐射探测器","authors":"A. A. Kozlov, A. V. Kozlov, V. E. Zavalova","doi":"10.1134/S0020441225700137","DOIUrl":null,"url":null,"abstract":"<p>A detector of pulsed neutron radiation of the activation type with continuous recording of registered pulses of secondary electrons in real time is described. As activation material, 0.3-mm-thick silver foil is used. An industrial grade SBM-19 gas-discharge Geiger–Muller counter, sensitive to hard beta and gamma radiation, was used to register secondary electrons. The recording interval of the accumulated number of registered secondary electron pulses is 10 s. The circular memory buffer used to record the secondary electron pulses is 16 MB, providing continuous recording for 2.5 years. A modern LiSOCl<sub>2</sub> galvanic cell with a voltage of 3.6 V and a capacity of 2.1 A h was used as a power source for the pulsed neutron radiation detector. The estimated operating time without replacing the battery is 5 years.</p>","PeriodicalId":587,"journal":{"name":"Instruments and Experimental Techniques","volume":"68 1","pages":"1 - 6"},"PeriodicalIF":0.4000,"publicationDate":"2025-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Activation Type Pulsed Neutron Radiation Detector with Continuous Recording of Registered Pulses of Secondary Electrons in Real Time\",\"authors\":\"A. A. Kozlov, A. V. Kozlov, V. E. Zavalova\",\"doi\":\"10.1134/S0020441225700137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A detector of pulsed neutron radiation of the activation type with continuous recording of registered pulses of secondary electrons in real time is described. As activation material, 0.3-mm-thick silver foil is used. An industrial grade SBM-19 gas-discharge Geiger–Muller counter, sensitive to hard beta and gamma radiation, was used to register secondary electrons. The recording interval of the accumulated number of registered secondary electron pulses is 10 s. The circular memory buffer used to record the secondary electron pulses is 16 MB, providing continuous recording for 2.5 years. A modern LiSOCl<sub>2</sub> galvanic cell with a voltage of 3.6 V and a capacity of 2.1 A h was used as a power source for the pulsed neutron radiation detector. The estimated operating time without replacing the battery is 5 years.</p>\",\"PeriodicalId\":587,\"journal\":{\"name\":\"Instruments and Experimental Techniques\",\"volume\":\"68 1\",\"pages\":\"1 - 6\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2025-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Instruments and Experimental Techniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S0020441225700137\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments and Experimental Techniques","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0020441225700137","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
介绍了一种实时连续记录二次电子记录脉冲的激活型脉冲中子辐射探测器。活化材料选用0.3 mm厚的银箔。工业级SBM-19气体放电盖革-穆勒计数器,对硬β和γ辐射敏感,用于记录二次电子。二次电子脉冲累计次数的记录间隔为10 s。用于记录二次电子脉冲的圆形存储缓冲区为16 MB,可连续记录2.5年。采用电压为3.6 V、容量为2.1 A h的现代LiSOCl2原电池作为脉冲中子辐射探测器的电源。不更换电池的预计使用时间为5年。
Activation Type Pulsed Neutron Radiation Detector with Continuous Recording of Registered Pulses of Secondary Electrons in Real Time
A detector of pulsed neutron radiation of the activation type with continuous recording of registered pulses of secondary electrons in real time is described. As activation material, 0.3-mm-thick silver foil is used. An industrial grade SBM-19 gas-discharge Geiger–Muller counter, sensitive to hard beta and gamma radiation, was used to register secondary electrons. The recording interval of the accumulated number of registered secondary electron pulses is 10 s. The circular memory buffer used to record the secondary electron pulses is 16 MB, providing continuous recording for 2.5 years. A modern LiSOCl2 galvanic cell with a voltage of 3.6 V and a capacity of 2.1 A h was used as a power source for the pulsed neutron radiation detector. The estimated operating time without replacing the battery is 5 years.
期刊介绍:
Instruments and Experimental Techniques is an international peer reviewed journal that publishes reviews describing advanced methods for physical measurements and techniques and original articles that present techniques for physical measurements, principles of operation, design, methods of application, and analysis of the operation of physical instruments used in all fields of experimental physics and when conducting measurements using physical methods and instruments in astronomy, natural sciences, chemistry, biology, medicine, and ecology.