一种用于汗液pH检测的柔性电化学传感器系统

IF 1.1 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Mei Wang, Yunqi Liu, Hao Zheng, Liying Jiang
{"title":"一种用于汗液pH检测的柔性电化学传感器系统","authors":"Mei Wang,&nbsp;Yunqi Liu,&nbsp;Hao Zheng,&nbsp;Liying Jiang","doi":"10.1134/S1061934825700315","DOIUrl":null,"url":null,"abstract":"<p>Sweat contains various substances that can indicate physiological parameters of the human body, indirectly reflecting the body’s fluid balance and overall health status. The pH value is an important indicator that can reflect skin health. Accurate detection of pH in sweat can provide insights into an individual’s health condition, making it highly significant in health management and disease prevention. In this study, a wireless, wearable sweat detection system based on a smartphone was designed. Gold nanoparticles and polyaniline were used to modify flexible screen-printed electrodes, and the open-circuit potential-time curve was employed to characterize the performance of the pH sensor. Experimental results show that the fabricated pH sensor exhibits a good linear response, stability, and repeatability, with a sensitivity of 63.04 mV/pH. The test results of the developed sweat detection system demonstrate its ability to accurately measure the pH value in sweat, indicating broad application prospects in the field of wearable sweat sensors and systems.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":"80 5","pages":"931 - 941"},"PeriodicalIF":1.1000,"publicationDate":"2025-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Flexible Electrochemical Sensor System for Sweat pH Detection\",\"authors\":\"Mei Wang,&nbsp;Yunqi Liu,&nbsp;Hao Zheng,&nbsp;Liying Jiang\",\"doi\":\"10.1134/S1061934825700315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Sweat contains various substances that can indicate physiological parameters of the human body, indirectly reflecting the body’s fluid balance and overall health status. The pH value is an important indicator that can reflect skin health. Accurate detection of pH in sweat can provide insights into an individual’s health condition, making it highly significant in health management and disease prevention. In this study, a wireless, wearable sweat detection system based on a smartphone was designed. Gold nanoparticles and polyaniline were used to modify flexible screen-printed electrodes, and the open-circuit potential-time curve was employed to characterize the performance of the pH sensor. Experimental results show that the fabricated pH sensor exhibits a good linear response, stability, and repeatability, with a sensitivity of 63.04 mV/pH. The test results of the developed sweat detection system demonstrate its ability to accurately measure the pH value in sweat, indicating broad application prospects in the field of wearable sweat sensors and systems.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":\"80 5\",\"pages\":\"931 - 941\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934825700315\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934825700315","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

汗液中含有各种能指示人体生理参数的物质,间接反映人体体液平衡和整体健康状况。pH值是反映皮肤健康状况的重要指标。准确检测汗液中的pH值可以深入了解个人的健康状况,使其在健康管理和疾病预防方面具有重要意义。本研究设计了一种基于智能手机的无线可穿戴汗液检测系统。采用金纳米粒子和聚苯胺修饰柔性丝网印刷电极,采用开路电位-时间曲线表征pH传感器的性能。实验结果表明,该传感器具有良好的线性响应、稳定性和重复性,灵敏度为63.04 mV/pH。研制的汗液检测系统的测试结果表明,该系统能够准确测量汗液中的pH值,在可穿戴式汗液传感器及系统领域具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A Flexible Electrochemical Sensor System for Sweat pH Detection

A Flexible Electrochemical Sensor System for Sweat pH Detection

Sweat contains various substances that can indicate physiological parameters of the human body, indirectly reflecting the body’s fluid balance and overall health status. The pH value is an important indicator that can reflect skin health. Accurate detection of pH in sweat can provide insights into an individual’s health condition, making it highly significant in health management and disease prevention. In this study, a wireless, wearable sweat detection system based on a smartphone was designed. Gold nanoparticles and polyaniline were used to modify flexible screen-printed electrodes, and the open-circuit potential-time curve was employed to characterize the performance of the pH sensor. Experimental results show that the fabricated pH sensor exhibits a good linear response, stability, and repeatability, with a sensitivity of 63.04 mV/pH. The test results of the developed sweat detection system demonstrate its ability to accurately measure the pH value in sweat, indicating broad application prospects in the field of wearable sweat sensors and systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信