Liam Marsden Back, Aleksandra Gentry-Maharaj, Andrew Ladwiniec
{"title":"镁基生物可吸收冠状动脉支架与聚l -乳酸基生物可吸收冠状动脉支架和现代药物洗脱冠状动脉支架的安全性和有效性比较——系统综述","authors":"Liam Marsden Back, Aleksandra Gentry-Maharaj, Andrew Ladwiniec","doi":"10.1155/crp/7481956","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Bioresorbable coronary stents (BRS) were designed with the aim of reducing the risk of late adverse events of permanent drug-eluting stents (DES) by dissolving once vessel patency had been restored and the requirement for acute mechanical support resolved. Bioresorbable poly-L-lactic acid (PLLA) scaffold designs, while initially appearing as promising technology, were unsuccessful in widespread clinical use due to an observed high rate of late stent thrombosis. Magnesium-based BRS (MgBRS) have provided an alternative to this original design and have shown promise in early-phase clinical trials. This review aims to address the clinical question: How does the current safety and efficacy evidence for MgBRS in all patients requiring percutaneous coronary intervention compare with the randomised data assessing PLLA-BRS and contemporary DES? <b>Methods:</b> Two parallel systematic reviews were performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, utilising MEDLINE, EMBASE and Web of Science: the first assessing clinical outcomes of all observational and randomised MgBRS trials, the second assessing clinical outcomes of PLLA-BRS versus DES in randomised clinical trials. The primary safety and efficacy outcomes collected were cardiac death, target vessel failure (TVF) and stent thrombosis. <b>Results:</b> A total of 3582 MgBRS patients (24 trials), 6370 PLLA-BRS and 5413 DES patients (16 trials) were included for analysis. Cardiac death was similar across all three stent designs in all time intervals. MgBRS performed similarly to contemporary DES and superiorly to PLLA-BRS at 12- and 24-month intervals with regard to TVF and stent thrombosis. Longer follow-up was suggestive of a poorer performance of MgBRS relative to DES, although with limited patient numbers. <b>Conclusion:</b> MgBRS appear to perform similarly to DES and superiorly to PLLA-BRS at 12 and 24 months in regard to key clinical safety and efficacy measures. Further randomised studies are required before recommending this technology for widespread clinical use over DES.</p>","PeriodicalId":9494,"journal":{"name":"Cardiology Research and Practice","volume":"2025 ","pages":"7481956"},"PeriodicalIF":2.1000,"publicationDate":"2025-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12457060/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Safety and Efficacy Profile of Magnesium-Based Bioresorbable Coronary Stents as Compared to Poly-L-Lactic Acid-Based Bioresorbable and Contemporary Drug-Eluting Coronary Stents-A Systematic Review.\",\"authors\":\"Liam Marsden Back, Aleksandra Gentry-Maharaj, Andrew Ladwiniec\",\"doi\":\"10.1155/crp/7481956\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Bioresorbable coronary stents (BRS) were designed with the aim of reducing the risk of late adverse events of permanent drug-eluting stents (DES) by dissolving once vessel patency had been restored and the requirement for acute mechanical support resolved. Bioresorbable poly-L-lactic acid (PLLA) scaffold designs, while initially appearing as promising technology, were unsuccessful in widespread clinical use due to an observed high rate of late stent thrombosis. Magnesium-based BRS (MgBRS) have provided an alternative to this original design and have shown promise in early-phase clinical trials. This review aims to address the clinical question: How does the current safety and efficacy evidence for MgBRS in all patients requiring percutaneous coronary intervention compare with the randomised data assessing PLLA-BRS and contemporary DES? <b>Methods:</b> Two parallel systematic reviews were performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, utilising MEDLINE, EMBASE and Web of Science: the first assessing clinical outcomes of all observational and randomised MgBRS trials, the second assessing clinical outcomes of PLLA-BRS versus DES in randomised clinical trials. The primary safety and efficacy outcomes collected were cardiac death, target vessel failure (TVF) and stent thrombosis. <b>Results:</b> A total of 3582 MgBRS patients (24 trials), 6370 PLLA-BRS and 5413 DES patients (16 trials) were included for analysis. Cardiac death was similar across all three stent designs in all time intervals. MgBRS performed similarly to contemporary DES and superiorly to PLLA-BRS at 12- and 24-month intervals with regard to TVF and stent thrombosis. Longer follow-up was suggestive of a poorer performance of MgBRS relative to DES, although with limited patient numbers. <b>Conclusion:</b> MgBRS appear to perform similarly to DES and superiorly to PLLA-BRS at 12 and 24 months in regard to key clinical safety and efficacy measures. Further randomised studies are required before recommending this technology for widespread clinical use over DES.</p>\",\"PeriodicalId\":9494,\"journal\":{\"name\":\"Cardiology Research and Practice\",\"volume\":\"2025 \",\"pages\":\"7481956\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12457060/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology Research and Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/crp/7481956\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology Research and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/crp/7481956","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
背景:生物可吸收冠状动脉支架(BRS)的设计旨在降低永久性药物洗脱支架(DES)后期不良事件的风险,一旦血管通畅恢复并解决急性机械支持的需求,BRS就会溶解。生物可吸收聚l -乳酸(PLLA)支架设计,虽然最初看起来是一种很有前途的技术,但由于观察到支架晚期血栓形成率高,未能广泛应用于临床。镁基BRS (MgBRS)为原始设计提供了一种替代方案,并在早期临床试验中显示出希望。本综述旨在解决临床问题:与评估PLLA-BRS和当代DES的随机数据相比,MgBRS在所有需要经皮冠状动脉介入治疗的患者中的安全性和有效性证据如何?方法:利用MEDLINE、EMBASE和Web of Science,使用系统评价和荟萃分析指南的首选报告项目进行了两项平行系统评价:第一项评估了所有观察性和随机MgBRS试验的临床结果,第二项评估了PLLA-BRS与DES在随机临床试验中的临床结果。收集的主要安全性和有效性结果是心脏性死亡、靶血管衰竭(TVF)和支架血栓形成。结果:共纳入MgBRS患者3582例(24项试验),PLLA-BRS患者6370例,DES患者5413例(16项试验)。在所有时间间隔内,三种支架设计的心脏死亡相似。MgBRS在TVF和支架血栓形成方面的表现与当代DES相似,优于pla - brs,间隔12个月和24个月。较长的随访时间提示MgBRS相对于DES的表现较差,尽管患者数量有限。结论:在关键的临床安全性和有效性指标方面,MgBRS在12个月和24个月的表现与DES相似,优于pla - brs。在推荐该技术在临床上广泛应用于DES之前,需要进一步的随机研究。
The Safety and Efficacy Profile of Magnesium-Based Bioresorbable Coronary Stents as Compared to Poly-L-Lactic Acid-Based Bioresorbable and Contemporary Drug-Eluting Coronary Stents-A Systematic Review.
Background: Bioresorbable coronary stents (BRS) were designed with the aim of reducing the risk of late adverse events of permanent drug-eluting stents (DES) by dissolving once vessel patency had been restored and the requirement for acute mechanical support resolved. Bioresorbable poly-L-lactic acid (PLLA) scaffold designs, while initially appearing as promising technology, were unsuccessful in widespread clinical use due to an observed high rate of late stent thrombosis. Magnesium-based BRS (MgBRS) have provided an alternative to this original design and have shown promise in early-phase clinical trials. This review aims to address the clinical question: How does the current safety and efficacy evidence for MgBRS in all patients requiring percutaneous coronary intervention compare with the randomised data assessing PLLA-BRS and contemporary DES? Methods: Two parallel systematic reviews were performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, utilising MEDLINE, EMBASE and Web of Science: the first assessing clinical outcomes of all observational and randomised MgBRS trials, the second assessing clinical outcomes of PLLA-BRS versus DES in randomised clinical trials. The primary safety and efficacy outcomes collected were cardiac death, target vessel failure (TVF) and stent thrombosis. Results: A total of 3582 MgBRS patients (24 trials), 6370 PLLA-BRS and 5413 DES patients (16 trials) were included for analysis. Cardiac death was similar across all three stent designs in all time intervals. MgBRS performed similarly to contemporary DES and superiorly to PLLA-BRS at 12- and 24-month intervals with regard to TVF and stent thrombosis. Longer follow-up was suggestive of a poorer performance of MgBRS relative to DES, although with limited patient numbers. Conclusion: MgBRS appear to perform similarly to DES and superiorly to PLLA-BRS at 12 and 24 months in regard to key clinical safety and efficacy measures. Further randomised studies are required before recommending this technology for widespread clinical use over DES.
期刊介绍:
Cardiology Research and Practice is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies that focus on the diagnosis and treatment of cardiovascular disease. The journal welcomes submissions related to systemic hypertension, arrhythmia, congestive heart failure, valvular heart disease, vascular disease, congenital heart disease, and cardiomyopathy.