不同边缘形态和表面纹理修复体的先进定制喷射增材制造成形能力

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Yingyue Su, Liren Liu, Jingxin Zhang, Shuangshan Deng, Maohua Yang, Shanshan Gao
{"title":"不同边缘形态和表面纹理修复体的先进定制喷射增材制造成形能力","authors":"Yingyue Su, Liren Liu, Jingxin Zhang, Shuangshan Deng, Maohua Yang, Shanshan Gao","doi":"10.1007/s00784-025-06544-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aims to investigate the forming capability of Advanced Customized Jetting (ACJ) technology for four different margin types restorations and five surface textures.</p><p><strong>Materials and methods: </strong>Zirconia restorations with four margin types (heavy-chamfer, chamfer, shoulder and biologically oriented preparation technique (BOPT)) were fabricated using CAD/CAM and ACJ technology (n = 10), then compared the root mean square (RMS) at non-marginal and Marginal regions. Surface textures were designed on 5 mm×5 mm× 5 mm cubes, including 11 groups: 1 non-porous (NP) group and 10 experimental groups with circular, triangular, square, pentagram, or hexagonal textures at 400 μm (D<sub>4</sub>) or 800 μm (D<sub>8</sub>) apertures (n = 10). ACJ fabricated textured samples were analyzed via SEM and 3D profilometry and measured dimensional accuracy along X/Y/Z axes.</p><p><strong>Results: </strong>(1) All ACJ restorations have lower RMS values at non-marginal regions than CAD/CAM (P < 0.01). ACJ fabricated heavy-chamfer, chamfer and BOPT restorations have lower RMS values at marginal region than CAD/CAM (P < 0.01), whereas no difference in shoulder (P > 0.05). (2) Circle and hexagon have the highest accuracy: D<sub>4</sub>C (90.58%), D<sub>8</sub>C (94.96%), D<sub>4</sub>H (87.29%) and D<sub>8</sub>H (92.96%), while pentagram has the lowest accuracy (D<sub>8</sub>P: 71.37%). The dimensional deviations of Z-axis are within 10 μm, and the accuracy of printing are above 90%.</p><p><strong>Conclusions: </strong>ACJ restorations exhibited lower RMS values than CAD/CAM in both non-marginal region and marginal region with heavy-chamfer, chamfer, and BOPT margins. Circle textures have the highest accuracy and larger aperture improves printing accuracy.</p><p><strong>Clinical relevance: </strong>ACJ fabricated zirconia restorations exhibit higher geometric precision and demonstrate technical feasibility in manufacturing customized morphological features.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"29 10","pages":"472"},"PeriodicalIF":3.1000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Forming capability of advanced customized jetting additive manufacturing for restorations with different margin morphologies and surface textures.\",\"authors\":\"Yingyue Su, Liren Liu, Jingxin Zhang, Shuangshan Deng, Maohua Yang, Shanshan Gao\",\"doi\":\"10.1007/s00784-025-06544-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aims to investigate the forming capability of Advanced Customized Jetting (ACJ) technology for four different margin types restorations and five surface textures.</p><p><strong>Materials and methods: </strong>Zirconia restorations with four margin types (heavy-chamfer, chamfer, shoulder and biologically oriented preparation technique (BOPT)) were fabricated using CAD/CAM and ACJ technology (n = 10), then compared the root mean square (RMS) at non-marginal and Marginal regions. Surface textures were designed on 5 mm×5 mm× 5 mm cubes, including 11 groups: 1 non-porous (NP) group and 10 experimental groups with circular, triangular, square, pentagram, or hexagonal textures at 400 μm (D<sub>4</sub>) or 800 μm (D<sub>8</sub>) apertures (n = 10). ACJ fabricated textured samples were analyzed via SEM and 3D profilometry and measured dimensional accuracy along X/Y/Z axes.</p><p><strong>Results: </strong>(1) All ACJ restorations have lower RMS values at non-marginal regions than CAD/CAM (P < 0.01). ACJ fabricated heavy-chamfer, chamfer and BOPT restorations have lower RMS values at marginal region than CAD/CAM (P < 0.01), whereas no difference in shoulder (P > 0.05). (2) Circle and hexagon have the highest accuracy: D<sub>4</sub>C (90.58%), D<sub>8</sub>C (94.96%), D<sub>4</sub>H (87.29%) and D<sub>8</sub>H (92.96%), while pentagram has the lowest accuracy (D<sub>8</sub>P: 71.37%). The dimensional deviations of Z-axis are within 10 μm, and the accuracy of printing are above 90%.</p><p><strong>Conclusions: </strong>ACJ restorations exhibited lower RMS values than CAD/CAM in both non-marginal region and marginal region with heavy-chamfer, chamfer, and BOPT margins. Circle textures have the highest accuracy and larger aperture improves printing accuracy.</p><p><strong>Clinical relevance: </strong>ACJ fabricated zirconia restorations exhibit higher geometric precision and demonstrate technical feasibility in manufacturing customized morphological features.</p>\",\"PeriodicalId\":10461,\"journal\":{\"name\":\"Clinical Oral Investigations\",\"volume\":\"29 10\",\"pages\":\"472\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Investigations\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00784-025-06544-6\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-025-06544-6","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究先进定制喷射(ACJ)技术在四种不同边缘类型修复体和五种表面纹理下的成形能力。材料与方法:采用CAD/CAM和ACJ技术制备四种边缘类型(重倒角、倒角、肩型和生物定向制备技术(BOPT))的氧化锆修复体(n = 10),比较非边缘和边缘区域的均方根(RMS)。在5个mm×5 mm×5 mm立方体上设计表面纹理,包括11组:1个无孔(NP)组和10个实验组,分别具有400 μm (D4)或800 μm (D8)孔径的圆形、三角形、正方形、五角形或六角形纹理(n = 10)。通过扫描电镜和三维轮廓术对ACJ织构样品进行了分析,并测量了沿X/Y/Z轴的尺寸精度。结果:(1)ACJ修复体在非边缘区域的RMS值均低于CAD/CAM修复体(P < 0.05)。(2)圆形和六角形的准确率最高,分别为D4C(90.58%)、D8C(94.96%)、D4H(87.29%)和D8H(92.96%),五角形的准确率最低,D8P为71.37%。z轴尺寸偏差在10 μm以内,打印精度在90%以上。结论:ACJ修复体在非边缘区域和边缘区域的RMS值均低于CAD/CAM修复体在重倒角、倒角和BOPT边缘的RMS值。圆形纹理具有最高的精度,较大的孔径提高了打印精度。临床意义:ACJ制造的氧化锆修复体具有更高的几何精度,并证明了制造定制形态特征的技术可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Forming capability of advanced customized jetting additive manufacturing for restorations with different margin morphologies and surface textures.

Objectives: This study aims to investigate the forming capability of Advanced Customized Jetting (ACJ) technology for four different margin types restorations and five surface textures.

Materials and methods: Zirconia restorations with four margin types (heavy-chamfer, chamfer, shoulder and biologically oriented preparation technique (BOPT)) were fabricated using CAD/CAM and ACJ technology (n = 10), then compared the root mean square (RMS) at non-marginal and Marginal regions. Surface textures were designed on 5 mm×5 mm× 5 mm cubes, including 11 groups: 1 non-porous (NP) group and 10 experimental groups with circular, triangular, square, pentagram, or hexagonal textures at 400 μm (D4) or 800 μm (D8) apertures (n = 10). ACJ fabricated textured samples were analyzed via SEM and 3D profilometry and measured dimensional accuracy along X/Y/Z axes.

Results: (1) All ACJ restorations have lower RMS values at non-marginal regions than CAD/CAM (P < 0.01). ACJ fabricated heavy-chamfer, chamfer and BOPT restorations have lower RMS values at marginal region than CAD/CAM (P < 0.01), whereas no difference in shoulder (P > 0.05). (2) Circle and hexagon have the highest accuracy: D4C (90.58%), D8C (94.96%), D4H (87.29%) and D8H (92.96%), while pentagram has the lowest accuracy (D8P: 71.37%). The dimensional deviations of Z-axis are within 10 μm, and the accuracy of printing are above 90%.

Conclusions: ACJ restorations exhibited lower RMS values than CAD/CAM in both non-marginal region and marginal region with heavy-chamfer, chamfer, and BOPT margins. Circle textures have the highest accuracy and larger aperture improves printing accuracy.

Clinical relevance: ACJ fabricated zirconia restorations exhibit higher geometric precision and demonstrate technical feasibility in manufacturing customized morphological features.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信