儿童创伤患者胸部和腹部计算机断层扫描的辐射暴露。

IF 1.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Daniel Rosok, Marcel Klaus Opitz, Denise Bos, Yannick Laurent Thal, Florian Behr, Marcel Alexander Drews, Raya Serger, Mathias Holtkamp, Luca Salhöfer, Marcel Dudda, Johannes Haubold, Benedikt Schaarschmidt, Bernd Schweiger, Lale Umutlu, Michael Forsting, Sebastian Zensen
{"title":"儿童创伤患者胸部和腹部计算机断层扫描的辐射暴露。","authors":"Daniel Rosok, Marcel Klaus Opitz, Denise Bos, Yannick Laurent Thal, Florian Behr, Marcel Alexander Drews, Raya Serger, Mathias Holtkamp, Luca Salhöfer, Marcel Dudda, Johannes Haubold, Benedikt Schaarschmidt, Bernd Schweiger, Lale Umutlu, Michael Forsting, Sebastian Zensen","doi":"10.1088/1361-6498/ae0a5a","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>&#xD;Combined chest and abdomen CT in pediatric trauma patients is rare and typically reserved for severely injured patients due to concerns about the potential radiation risks associated with CT in children. This study aims to analyze the radiation exposure of chest and abdomen CT in pediatric patients following trauma resuscitation.&#xD;&#xD;Materials and Methods:&#xD;A retrospective single-center study was conducted on patients aged 0-<15 years who underwent CT in the trauma resuscitation unit between 04/2020 and 08/2023. Patients were categorized into three age groups (I: 0-<5 years, II: 5-<10 years, III: 10-<15 years) and radiation exposure parameters were analyzed age-stratified. Effective dose (ED) was calculated using conversion factors and organ doses were determined through Monte Carlo simulations.&#xD;&#xD;Results:&#xD;Out of 212 pediatric patients, 62.7% (133/212) received a CT scan, with 60.2% (80/133) undergoing combined chest and abdomen CT. In 70.0% (56/80), the standard protocol was applied, complete dose data available, and these were included in the dose calculation (median age: 6.2 years; IQR: 3.9-10.5 years; 37.5% female). &#xD;Radiation exposure was as follows (median [IQR] CTDIvol, DLP, ED): chest: I: 0.7 mGy (0.5-0.8), 13 mGycm (10-16), 2.1 mSv (1.6-2.4); II: 1.4 mGy (1.1-1.9), 35 mGycm (25-49), 3.7 mSv (2.7-5.2); III: 2.7 mGy (2.2-3.2), 76 mGycm (66-95), 4.3 mSv (3.7-5.3); abdomen: I: 0.8 mGy (0.6-0.9), 24 mGycm (20-29), 2.0 mSv (1.6-2.5); II: 1.6 mGy (1.1-1.9), 60 mGycm (41-77), 3.2 mSv (2.2-4.2); III: 3.1 mGy (2.4-3.9), 143 mGycm (101-179), 4.3 mSv (3.0-5.4). In the organ dose analysis, the genital organs were particularly affected by increased radiation exposure. 16.1% (9/56) of patients were not scanned using age-adapted protocols.&#xD;&#xD;Conclusion:&#xD;Chest and abdomen CT in pediatric trauma patients can be performed with moderate radiation exposure. Nonetheless, non-adherence to age-adapted protocols highlights the need for improved compliance to ensure optimal radiation safety in pediatric trauma imaging.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiation exposure of chest and abdomen computed tomography in pediatric trauma patients.\",\"authors\":\"Daniel Rosok, Marcel Klaus Opitz, Denise Bos, Yannick Laurent Thal, Florian Behr, Marcel Alexander Drews, Raya Serger, Mathias Holtkamp, Luca Salhöfer, Marcel Dudda, Johannes Haubold, Benedikt Schaarschmidt, Bernd Schweiger, Lale Umutlu, Michael Forsting, Sebastian Zensen\",\"doi\":\"10.1088/1361-6498/ae0a5a\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>&#xD;Combined chest and abdomen CT in pediatric trauma patients is rare and typically reserved for severely injured patients due to concerns about the potential radiation risks associated with CT in children. This study aims to analyze the radiation exposure of chest and abdomen CT in pediatric patients following trauma resuscitation.&#xD;&#xD;Materials and Methods:&#xD;A retrospective single-center study was conducted on patients aged 0-<15 years who underwent CT in the trauma resuscitation unit between 04/2020 and 08/2023. Patients were categorized into three age groups (I: 0-<5 years, II: 5-<10 years, III: 10-<15 years) and radiation exposure parameters were analyzed age-stratified. Effective dose (ED) was calculated using conversion factors and organ doses were determined through Monte Carlo simulations.&#xD;&#xD;Results:&#xD;Out of 212 pediatric patients, 62.7% (133/212) received a CT scan, with 60.2% (80/133) undergoing combined chest and abdomen CT. In 70.0% (56/80), the standard protocol was applied, complete dose data available, and these were included in the dose calculation (median age: 6.2 years; IQR: 3.9-10.5 years; 37.5% female). &#xD;Radiation exposure was as follows (median [IQR] CTDIvol, DLP, ED): chest: I: 0.7 mGy (0.5-0.8), 13 mGycm (10-16), 2.1 mSv (1.6-2.4); II: 1.4 mGy (1.1-1.9), 35 mGycm (25-49), 3.7 mSv (2.7-5.2); III: 2.7 mGy (2.2-3.2), 76 mGycm (66-95), 4.3 mSv (3.7-5.3); abdomen: I: 0.8 mGy (0.6-0.9), 24 mGycm (20-29), 2.0 mSv (1.6-2.5); II: 1.6 mGy (1.1-1.9), 60 mGycm (41-77), 3.2 mSv (2.2-4.2); III: 3.1 mGy (2.4-3.9), 143 mGycm (101-179), 4.3 mSv (3.0-5.4). In the organ dose analysis, the genital organs were particularly affected by increased radiation exposure. 16.1% (9/56) of patients were not scanned using age-adapted protocols.&#xD;&#xD;Conclusion:&#xD;Chest and abdomen CT in pediatric trauma patients can be performed with moderate radiation exposure. Nonetheless, non-adherence to age-adapted protocols highlights the need for improved compliance to ensure optimal radiation safety in pediatric trauma imaging.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ae0a5a\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ae0a5a","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景:由于担心儿童CT的潜在辐射风险,胸腹联合CT在儿童创伤患者中的应用很少见,通常只用于严重损伤患者。本研究旨在分析儿童外伤复苏后胸腹CT的辐射暴露情况。材料与方法:采用回顾性单中心研究,年龄0 ~ 0岁
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiation exposure of chest and abdomen computed tomography in pediatric trauma patients.

Background: Combined chest and abdomen CT in pediatric trauma patients is rare and typically reserved for severely injured patients due to concerns about the potential radiation risks associated with CT in children. This study aims to analyze the radiation exposure of chest and abdomen CT in pediatric patients following trauma resuscitation. Materials and Methods: A retrospective single-center study was conducted on patients aged 0-<15 years who underwent CT in the trauma resuscitation unit between 04/2020 and 08/2023. Patients were categorized into three age groups (I: 0-<5 years, II: 5-<10 years, III: 10-<15 years) and radiation exposure parameters were analyzed age-stratified. Effective dose (ED) was calculated using conversion factors and organ doses were determined through Monte Carlo simulations. Results: Out of 212 pediatric patients, 62.7% (133/212) received a CT scan, with 60.2% (80/133) undergoing combined chest and abdomen CT. In 70.0% (56/80), the standard protocol was applied, complete dose data available, and these were included in the dose calculation (median age: 6.2 years; IQR: 3.9-10.5 years; 37.5% female). Radiation exposure was as follows (median [IQR] CTDIvol, DLP, ED): chest: I: 0.7 mGy (0.5-0.8), 13 mGycm (10-16), 2.1 mSv (1.6-2.4); II: 1.4 mGy (1.1-1.9), 35 mGycm (25-49), 3.7 mSv (2.7-5.2); III: 2.7 mGy (2.2-3.2), 76 mGycm (66-95), 4.3 mSv (3.7-5.3); abdomen: I: 0.8 mGy (0.6-0.9), 24 mGycm (20-29), 2.0 mSv (1.6-2.5); II: 1.6 mGy (1.1-1.9), 60 mGycm (41-77), 3.2 mSv (2.2-4.2); III: 3.1 mGy (2.4-3.9), 143 mGycm (101-179), 4.3 mSv (3.0-5.4). In the organ dose analysis, the genital organs were particularly affected by increased radiation exposure. 16.1% (9/56) of patients were not scanned using age-adapted protocols. Conclusion: Chest and abdomen CT in pediatric trauma patients can be performed with moderate radiation exposure. Nonetheless, non-adherence to age-adapted protocols highlights the need for improved compliance to ensure optimal radiation safety in pediatric trauma imaging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信