{"title":"同时检测γ-US的集成γ-超声(γ-US)探头检测器和多路读出器的研制。","authors":"Muhammad Nasir Ullah, Muhammad Waqar, Yuseung Park, Gyeong Beom Kim, Kyungseok Choi, Seungjoo Jang, Chanyoung Kim, Qifa Zhou, Hojong Choi, Jung-Yeol Yeom","doi":"10.1109/TUFFC.2025.3612985","DOIUrl":null,"url":null,"abstract":"<p><p>This paper presents the first fully integrated, highly compact single-element integrated Gamma-Ultrasound (γ-US) probe for simultaneous molecular and anatomical imaging. The probe integrates a PZT-5A US transducer with a Ce:GAGG scintillator and silicon photomultiplier (SiPM), enabling dual-modality detection along the same line-of-sight (LOS). The tungsten-epoxy composite serves dual roles as both the US backing layer and γ collimator, making it innovative and significantly reduces size and complexity. Furthermore, a single-channel frequency-based multiplexed circuit enables real-time dual-modality data acquisition. The γ part of the probe achieves 17.3% energy resolution (FWHM at 122 keV), 80.0 cps/MBq sensitivity, and 2.69 mm spatial resolution at 1 cm distance in air. The US component provides a 5.95 dB SNR, 1.32 mm axial resolution, and 4.90 mm lateral resolution at 5 cm depth in water. Finally, a fused B-mode image of a breast phantom validates the probe's imaging capability. This integrated probe design offers a compact, cost-effective solution for handheld medical diagnostics and non-destructive testing, with minimal performance trade-offs compared to standalone systems.</p>","PeriodicalId":13322,"journal":{"name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","volume":"PP ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of An Integrated Gamma-Ultrasound (γ-US) Probe Detector and Multiplexed Readout for Simultaneous γ-US Detection.\",\"authors\":\"Muhammad Nasir Ullah, Muhammad Waqar, Yuseung Park, Gyeong Beom Kim, Kyungseok Choi, Seungjoo Jang, Chanyoung Kim, Qifa Zhou, Hojong Choi, Jung-Yeol Yeom\",\"doi\":\"10.1109/TUFFC.2025.3612985\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper presents the first fully integrated, highly compact single-element integrated Gamma-Ultrasound (γ-US) probe for simultaneous molecular and anatomical imaging. The probe integrates a PZT-5A US transducer with a Ce:GAGG scintillator and silicon photomultiplier (SiPM), enabling dual-modality detection along the same line-of-sight (LOS). The tungsten-epoxy composite serves dual roles as both the US backing layer and γ collimator, making it innovative and significantly reduces size and complexity. Furthermore, a single-channel frequency-based multiplexed circuit enables real-time dual-modality data acquisition. The γ part of the probe achieves 17.3% energy resolution (FWHM at 122 keV), 80.0 cps/MBq sensitivity, and 2.69 mm spatial resolution at 1 cm distance in air. The US component provides a 5.95 dB SNR, 1.32 mm axial resolution, and 4.90 mm lateral resolution at 5 cm depth in water. Finally, a fused B-mode image of a breast phantom validates the probe's imaging capability. This integrated probe design offers a compact, cost-effective solution for handheld medical diagnostics and non-destructive testing, with minimal performance trade-offs compared to standalone systems.</p>\",\"PeriodicalId\":13322,\"journal\":{\"name\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on ultrasonics, ferroelectrics, and frequency control\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/TUFFC.2025.3612985\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TUFFC.2025.3612985","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了第一个完全集成的,高度紧凑的单元素集成γ-超声(γ-US)探针,用于同时进行分子和解剖成像。探头集成了PZT-5A US换能器、Ce:GAGG闪烁体和硅光电倍增管(SiPM),实现沿相同视距(LOS)的双模检测。钨-环氧复合材料具有双重作用,既可以作为美国底层,也可以作为γ准直器,使其具有创新性,并显着降低了尺寸和复杂性。此外,单通道基于频率的多路复用电路可实现实时双模态数据采集。探针γ部分的能量分辨率达到17.3% (122 keV时的FWHM),灵敏度为80.0 cps/MBq,在空气中1厘米距离的空间分辨率为2.69 mm。美国组件提供5.95 dB信噪比,1.32 mm轴向分辨率和4.90 mm横向分辨率,水深为5cm。最后,乳房假体的融合b模式图像验证了探针的成像能力。这种集成探头设计为手持式医疗诊断和无损检测提供了一种紧凑、经济高效的解决方案,与独立系统相比,性能折衷最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of An Integrated Gamma-Ultrasound (γ-US) Probe Detector and Multiplexed Readout for Simultaneous γ-US Detection.

This paper presents the first fully integrated, highly compact single-element integrated Gamma-Ultrasound (γ-US) probe for simultaneous molecular and anatomical imaging. The probe integrates a PZT-5A US transducer with a Ce:GAGG scintillator and silicon photomultiplier (SiPM), enabling dual-modality detection along the same line-of-sight (LOS). The tungsten-epoxy composite serves dual roles as both the US backing layer and γ collimator, making it innovative and significantly reduces size and complexity. Furthermore, a single-channel frequency-based multiplexed circuit enables real-time dual-modality data acquisition. The γ part of the probe achieves 17.3% energy resolution (FWHM at 122 keV), 80.0 cps/MBq sensitivity, and 2.69 mm spatial resolution at 1 cm distance in air. The US component provides a 5.95 dB SNR, 1.32 mm axial resolution, and 4.90 mm lateral resolution at 5 cm depth in water. Finally, a fused B-mode image of a breast phantom validates the probe's imaging capability. This integrated probe design offers a compact, cost-effective solution for handheld medical diagnostics and non-destructive testing, with minimal performance trade-offs compared to standalone systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.70
自引率
16.70%
发文量
583
审稿时长
4.5 months
期刊介绍: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control includes the theory, technology, materials, and applications relating to: (1) the generation, transmission, and detection of ultrasonic waves and related phenomena; (2) medical ultrasound, including hyperthermia, bioeffects, tissue characterization and imaging; (3) ferroelectric, piezoelectric, and piezomagnetic materials, including crystals, polycrystalline solids, films, polymers, and composites; (4) frequency control, timing and time distribution, including crystal oscillators and other means of classical frequency control, and atomic, molecular and laser frequency control standards. Areas of interest range from fundamental studies to the design and/or applications of devices and systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信